114 resultados para TRANSCRANIAL DOPPLER ULTRASONOGRAPHY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the intraoperative courses of 2 consecutive Berlin Heart Excor® Pediatric Ventricular Assist Device implantations, in which transcranial Doppler ultrasonography helped to detect macroscopically undetected residual air bubbles captured in the pump after air removal had been correctly performed according to manufacturer's specifications. Our experience with these cases suggests that a beat-to beat deairing maneuver guided by transcranial Doppler is a useful strategy for reducing cerebral exposure to perioperative gaseous microembolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The suspected cause of clinical manifestations of patent foramen ovale (PFO) is a transient or a permanent right-to-left shunt (RLS). Contrast-enhanced transcranial Doppler ultrasound (c-TCD) is a reliable alternative to transesophageal echocardiography (TEE) for diagnosis of PFO, and enables also the detection of extracardiac RLS. The air-containing echo contrast agents are injected intravenously and do not pass the pulmonary circulation. In the presence of RLS, the contrast agents bypass the pulmonary circulation and cause microembolic signals (MES) in the basal cerebral arteries, which are detected by TCD. The two main echo contrast agents in use are agitated saline and D-galactose microparticle solutions. At least one middle cerebral artery (MCA) is insonated, and the ultrasound probe is fixed with a headframe. The monitored Doppler spectra are stored for offline analysis (e.g., videotape) of the time of occurrence and number of MES, which are used to assess the size and functional relevance of the RLS. The examination is more sensitive, if both MCAs are investigated. In the case of negative testing, the examination is repeated using the Valsalva maneuver. Compared to TEE, c-TCD is more comfortable for the patient, enables an easier assessment of the size and functional relevance of the RLS, and allows also the detection of extracardiac RLS. However, c-TCD cannot localize the site of the RLS. Therefore, TEE and TCD are complementary methods and should be applied jointly in order to increase the diagnostic accuracy for detecting PFO and other types of RLS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. METHOD: 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. RESULTS: The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). CONCLUSIONS: Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to describe magnetic resonance imaging (MRI) findings associated with presumed elevated intracranial pressure (ICP) in dogs and to evaluate whether MRI could be used to discriminate between dogs with and without elevated ICP. Of 91 dogs that underwent cranial MRI examination, 18 (19.8%) were diagnosed with elevated ICP based on neurological examination, fundoscopy and transcranial Doppler ultrasonography. The MRI findings that showed the strongest association with elevated ICP were mass effect (odds ratio [OR], 78.5), caudal transtentorial herniation (OR, 72.0), subfalcine herniation (OR, 45.6), perilesional oedema (OR, 34.0), displacement of the lamina quadrigemina (OR, 27.7) and effacement of the cerebral sulci (OR, 27.1). The presence of any two or more of the following MRI findings identified elevated ICP with a sensitivity of 72% and a specificity of 96%: compression of the suprapineal recess, compression of the third ventricle, compression of the fourth ventricle, effacement of the cerebral sulci and caudal transposition of the lamina quadrigemina. In conclusion, there is an association between MRI findings and elevated ICP in dogs; therefore, MRI might be useful to discriminate between dogs with and without elevated ICP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Failing cerebral blood flow (CBF) autoregulation may contribute to cerebral damage after traumatic brain injury (TBI). The purpose of this study was to describe the time course of CO(2)-dependent vasoreactivity, measured as CBF velocity in response to hyperventilation (vasomotor reactivity [VMR] index). We included 13 patients who had had severe TBI, 8 of whom received norepinephrine (NE) based on clinical indication. In these patients, measurements were also performed after dobutamine administration, with a goal of increasing cardiac output by 30%. Blood flow velocity was measured with transcranial Doppler ultrasound in both hemispheres. All patients except one had an abnormal VMR index in at least one hemisphere within the first 24 h after TBI. In those patients who did not receive catecholamines, mean VMR index recovered within the first 48 to 72 h. In contrast, in patients who received NE within the first 48 h period, VMR index did not recover on the second day. Cardiac output and mean CBF velocity increased significantly during dobutamine administration, but VMR index did not change significantly. In conclusion, CO(2) vasomotor reactivity was abnormal in the first 24 h after TBI in most of the patients, but recovered within 48 h in those patients who did not receive NE, in contrast to those eventually receiving the drug. Addition of dobutamine to NE had variable but overall insignificant effects on CO(2) vasomotor reactivity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Syncope is defined as an acute, brief and transient loss of consciousness and postural tone with spontaneous and complete recovery. Neurovascular ultrasound has contributed to elucidate the underlying mechanism of different types of syncope. In routine diagnostic work-up of patients with syncope, however, neurovascular ultrasound is not among the first line tools. In particular, an ultrasound search for occlusive cerebro-vascular disease is of limited value because cerebral artery obstruction is a very rare and questionable cause of syncope. Transcranial Doppler sonography monitoring of the cerebral arteries is useful in the diagnostic work-up of patients with suspicion of postural related, cerebrovascular, cough and psychogenic syncope, and in some cases for differentiating focal epileptic seizures from transient ischemic attacks and migraine with aura.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Digital volume pulse (DVP), a noninvasive method for indirect assessment of arterial stiffness, was not tested previously in patients with end-stage renal disease (ESRD). Therefore, we compared the DVP-derived stiffness index (SI(DVP)) with aortic pulse wave velocity (PWV) determined by means of Doppler ultrasonography in 2 groups of patients with ESRD and analyzed the correlation between SI(DVP) and comorbidity. METHODS: Photoplethysmography was performed on the index finger of the dominant hand or the hand from the nonfistula arm in 49 renal transplant (TX) recipients and 48 hemodialysis (HD) patients. Pulse curves were analyzed with computer assistance. Comorbidity was assessed by using an established index. RESULTS: The intrasubject variability of SI(DVP) was 5.7%. SI(DVP) and aortic PWV values correlated significantly (r = 0.66; P = 0.001) in patients with ESRD. SI(DVP) could not be assessed reliably in 25% and 6% of HD patients and TX recipients, respectively. Multivariate regression analyses showed that SI(DVP) increased with age in both HD patients and TX recipients (r = 0.61; P < 0.001) and with systolic blood pressure (r = 0.53; P < 0.025), mean arterial pressure (r = 0.47; P < 0.05), and pulse pressure (r = 0.52; P = 0.02) in TX recipients. Severity of comorbid status was associated highly with individual residuals of age-adjusted SI(DVP) in HD patients and TX recipients (P < 0.001). CONCLUSION: DVP allows the measurement of arterial stiffness in most, but not all, patients with ESRD. SI(DVP) values correlate with comorbidity in HD patients and TX recipients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the primary success and short-term patency associated with a new 4-F sheath-compatible self-expanding nitinol stent after failed conventional angioplasty of distal popliteal and infrapopliteal lesions in severe lifestyle-limiting claudication (LLC) and chronic critical limb ischemia (CLI). MATERIALS AND METHODS: Between May 2003 and July 2005, 35 patients with Rutherford category 3-5 disease (16 patients with CLI, 19 patients with LLC) underwent percutaneous transluminal angioplasty (PTA) and stent implantation. Indications for stent placement were residual stenosis, flow-limiting dissections, or elastic recoil after PTA. Before and after the intervention and during the 6-month follow-up, clinical investigation, color-flow and duplex Doppler ultrasonography, and digital subtraction angiography were performed. Technical success, primary patency at 6 months, clinical improvement as defined by Rutherford with clinical and hemodynamic measures, and complications were evaluated. RESULTS: A total of 22 patients underwent distal popliteal artery stent placement and 13 underwent tibioperoneal artery stent placement. Stent implantation was successfully performed in all patients. After stent placement, the primary cumulative patency rate for the study group at 6 months was 82%. The mean resting ankle-brachial index at baseline was 0.50 +/- 0.16 and significantly increased to 0.90 +/- 0.17 at 12-24 hours after intervention and 0.82 +/- 0.24 at latest follow-up (P < .001 for both). The sustained clinical improvement rate was 80% at the 6-month follow-up. The 6-month limb salvage rate regarding major amputation was 100%. The rate of major complications was 17%. CONCLUSIONS: Infrapopliteal application of the new nitinol stent is a safe, feasible, and effective method with good short-term patency rate in the treatment of severe LLC and chronic CLI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Implantation of stents into the bronchial walls is a newly developed method to treat lung emphysema, which is now being tested clinically. During this procedure, a bronchoscope carrying a Doppler ultrasonography head is placed into a segmental bronchus and the blood vessels running in parallel to the bronchus are localized. Once a safe location without blood vessels is found, the bronchial wall is perforated and a stent is placed within the wall to improve the expiratory volume of these "bypasses" to the adjacent lung parenchyma. We observed a fatal complication with this method in a 60-year-old man. The bronchial wall and the pulmonary artery were perforated by one of the stents inducing massive bleeding, which could not be stopped. The patient died due to aspiration of blood in combination with massive loss of blood. The general risk to perforate the pulmonary artery during this procedure cannot be estimated from this single observation but should be considered regarding the legal and clinical aspects.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To retrospectively evaluate the midterm patency rate of the nitinol (Viatorr, W.L. Gore and Associates, Flagstaff, Ariz) stent-graft for direct intrahepatic portacaval shunt (DIPS) creation. MATERIALS AND METHODS: Institutional Review Board approval for this retrospective HIPAA-compliant study was obtained with waiver of informed consent. DIPS was created in 18 men and one woman (median age, 54 years; range, 45-65 years) by using nitinol polytetrafluoroethylene (PTFE)-covered stent-grafts. The primary indications were intractable ascites (n = 14), acute variceal bleeding (n = 3), and hydrothorax (n = 2). Follow-up included Doppler ultrasonography at 1, 6, and 12 months and venography with manometry at 6-month intervals after the procedure. Shunt patency and cumulative survival were evaluated by using the Kaplan-Meier method and survival curves were plotted. Differences in mean portosystemic gradients (PSGs) were evaluated by using the Student t test. Multiple regression analysis for survival and DIPS patency were performed for the following parameters: Child-Pugh class, model of end-stage liver disease score, pre- and post-DIPS PSGs, pre-DIPS liver function tests, and pre-DIPS creatinine levels. RESULTS: DIPS creation was successful in all patients. Effective portal decompression and free antegrade shunt flow was achieved in all patients. Intraperitoneal bleeding occurred in one patient during the procedure and was controlled during the same procedure by placing a second nitinol stent-graft. The primary patency rate was 100% at all times during the follow-up period (range, 2 days to 30 months; mean, 256 days; median, 160 days). Flow restrictors were deployed in two (11%) of 19 patients. The 1-year mortality rate was 37% (seven of 19). CONCLUSION: Patency after DIPS creation with the nitinol PTFE-covered stent-graft was superior to that after TIPS with the nitinol stent-graft.