39 resultados para Stereology

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The ultrastructure of venous valves and walls in chronic venous disease was investigated. METHODS: Consecutive patients were categorised into one of three groups (group A: patients with C1 venous disease in accordance with CEAP (Clinical severity, Etiology, Anatomy, Pathophysiology); group B: C2 and C3; group C: C4, C5 and C6). The terminal or preterminal valve and adjacent vessel wall was harvested from the great saphenous vein. Sections were examined with a transmission electron microscope. The volumes of elastin and of collagen per unit surface area of valve were assessed, as well as the surface endothelium of valve and vessel wall. RESULTS: The study population consisted of 17 patients. The elastin ratio was analysed by means of stereology. Mean values were: in group A, 0.45 μm3/m2; in group B, 0.67 μm3/m2; in group C, 0.97 μm3/m2. The ratio was similar for collagen (A, 15.7 μm3/m2; B, 26.8 μm3/m2; C, 30.1 μm3/m2). Surface analysis of the valve endothelium and the adjacent vessel wall endothelium showed a trend towards increasing damage with more severe disease. CONCLUSIONS: With progression of venous disease, the valve elastin content, assessed morphologically, seems to increase, and the endothelium of the venous valve and the vein wall tend to show more damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantification of the structural properties of snow is traditionally based on model-based stereology. Model-based stereology requires assumptions about the shape of the investigated structure. Here, we show how the density, specific surface area, and grain boundary area can be measured using a design-based method, where no assumptions about structural properties are necessary. The stereological results were also compared to X-ray tomography to control the accuracy of the method. The specific surface area calculated with the stereological method was 19.8 ± 12.3% smaller than with X-ray tomography. For the density, the stereological method gave results that were 11.7 ± 12.1% larger than X-ray tomography. The statistical analysis of the estimates confirmed that the stereological method and the sampling used are accurate. This stereological method was successfully tested on artificially produced ice beads but also on several snow types. Combining stereology and polarisation microscopy provides a good estimate of grain boundary areas in ice beads and in natural snow, with some limitatio

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative data on lung structure are essential to set up structure-function models for assessing the functional performance of the lung or to make statistically valid comparisons in experimental morphology, physiology, or pathology. The methods of choice for microscopy-based lung morphometry are those of stereology, the science of quantitative characterization of irregular three-dimensional objects on the basis of measurements made on two-dimensional sections. From a practical perspective, stereology is an assumption-free set of methods of unbiased sampling with geometric probes, based on a solid mathematical foundation. Here, we discuss the pitfalls of lung morphometry and present solutions, from specimen preparation to the sampling scheme in multiple stages, for obtaining unbiased estimates of morphometric parameters such as volumes, surfaces, lengths, and numbers. This is demonstrated on various examples. Stereological methods are accurate, efficient, simple, and transparent; the precision of the estimates depends on the size and distribution of the sample. For obtaining quantitative data on lung structure at all microscopic levels, state-of-the-art stereology is the gold standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung stereology has a long and successful tradition. From mice to men, the application of new stereological methods at several levels (alveoli, parenchymal cells, organelles, proteins) has led to new insights into normal lung architecture, parenchymal remodelling in emphysema-like pathology, alveolar type II cell hyperplasia and hypertrophy and intracellular surfactant alterations as well as distribution of surfactant proteins. The Euler number of the network of alveolar openings, estimated using physical disectors at the light microscopic level, is an unbiased and direct estimate of alveolar number. Surfactant-producing alveolar type II cells can be counted and sampled for local size estimation with physical disectors at a high magnification light microscopic level. The number of their surfactant storage organelles, lamellar bodies, can be estimated using physical disectors at the EM level. By immunoelectron microscopy, surfactant protein distribution can be analysed with the relative labelling index. Together with the well-established classical stereological methods, these design-based methods now allow for a complete quantitative phenotype analysis in lung development and disease, including the structural characterization of gene-manipulated mice, at the light and electron microscopic level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stereological tools are the gold standard for accurate (i.e., unbiased) and precise quantification of any microscopic sample. The past decades have provided a broad spectrum of tools to estimate a variety of parameters such as volumes, surfaces, lengths, and numbers. Some of them require pairs of parallel sections that can be produced by either physical or optical sectioning, with optical sectioning being much more efficient when applicable. Unfortunately, transmission electron microscopy could not fully profit from these riches, mainly because of the large depth of field. Hence, optical sectioning was a long-time desire for electron microscopists. This desire was fulfilled with the development of electron tomography that yield stacks of slices from electron microscopic sections. Now, parallel optical slices of a previously unimagined small thickness (2-5 nm axial resolution) can be produced. These optical slices minimize problems related to overprojection effects, and allow for direct stereological analysis, e.g., volume estimation with the Cavalieri principle and number estimation with the optical disector method. Here, we demonstrate that the symbiosis of stereology and electron tomography is an easy and efficient way for quantitative analysis at the electron microscopic level. We call this approach quantitative 3D electron microscopy.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stereological tools are the gold standard for accurate (i.e., unbiased) and precise quantification of any microscopic sample. The past decades have provided a broad spectrum of tools to estimate a variety of parameters such as volumes, surfaces, lengths, and numbers. Some of them require pairs of parallel sections that can be produced by either physical or optical sectioning, with optical sectioning being much more efficient when applicable. Unfortunately, transmission electron microscopy could not fully profit from these riches, mainly because of the large depth of field. Hence, optical sectioning was a long-time desire for electron microscopists. This desire was fulfilled with the development of electron tomography that yield stacks of slices from electron microscopic sections. Now, parallel optical slices of a previously unimagined small thickness (2-5nm axial resolution) can be produced. These optical slices minimize problems related to overprojection effects, and allow for direct stereological analysis, e.g., volume estimation with the Cavalieri principle and number estimation with the optical disector method. Here, we demonstrate that the symbiosis of stereology and electron tomography is an easy and efficient way for quantitative analysis at the electron microscopic level. We call this approach quantitative 3D electron microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative data obtained by means of design-based stereology can add valuable information to studies performed on a diversity of organs, in particular when correlated to functional/physiological and biochemical data. Design-based stereology is based on a sound statistical background and can be used to generate accurate data which are in line with principles of good laboratory practice. In addition, by adjusting the study design an appropriate precision can be achieved to find relevant differences between groups. For the success of the stereological assessment detailed planning is necessary. In this review we focus on common pitfalls encountered during stereological assessment. An exemplary workflow is included, and based on authentic examples, we illustrate a number of sampling principles which can be implemented to obtain properly sampled tissue blocks for various purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present local stereological estimators of Minkowski tensors defined on convex bodies in ℝ d . Special cases cover a number of well-known local stereological estimators of volume and surface area in ℝ3, but the general set-up also provides new local stereological estimators of various types of centres of gravity and tensors of rank two. Rank two tensors can be represented as ellipsoids and contain information about shape and orientation. The performance of some of the estimators of centres of gravity and volume tensors of rank two is investigated by simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chick chorioallantoic membrane (CAM) is a widely used model for the study of angiogenesis, tumour growth, as well as drug efficacy. In spite of this, little is known about the developmental alteration from its appearance to the time of hatching. In the current study the CAM has been studied by classical stereology and allometry. Expression levels of selected angiogenesis-related molecules were estimated by RT-PCR and cell dynamics assessed by proliferation and apoptosis assays. Absolute CAM volume increased from a low of 0.47 ± 0.11 cm3 at embryonic day 8 (E8) to a high of 2.05 ± 0.27 cm3 at E18, and then decreased to 1.6 ± 0.47 cm3 at E20. On allometric analysis, three growth phases were identifiable. Between E8-13 (phase I), the CAM grew fastest; moderately in phase II (E13-18) but was regressing in phase III (E18-20). The chorion, the mesenchyme and the allantoic layers grew fastest in phase I, but moderately in phase II. The mesenchyme grew slowly in phase III while the chorion and allantois were regressing. Chorionic cell volume increased fastest in phase I and was regressing in phase III. Chorionic capillaries grew steadily in phase I and II but regressed in phase III. Both the chorion and the allantois grew by intrinsic cell proliferation as well as recruitment of cells from the mesenchyme. Cell proliferation was prominent in the allantois and chorion early during development, declined after E17 and apoptosis started mainly in the chorion from E14. VEGFR2 expression peaked at E11 and declined steadily towards E20, VEGF peaked at E13 and E20 while HIF 1α had a peak at E11 and E20. Studies targeting CAM growth and angiogenesis need to take these growth phases into consideration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The impact of nanoparticles (NPs) in medicine and biology has increased rapidly in recent years. Gold NPs have advantageous properties such as chemical stability, high electron density and affinity to biomolecules, making them very promising candidates as drug carriers and diagnostic tools. However, diverse studies on the toxicity of gold NPs have reported contradictory results. To address this issue, a triple cell co-culture model simulating the alveolar lung epithelium was used and exposed at the air-liquid interface. The cell cultures were exposed to characterized aerosols with 15 nm gold particles (61 ng Au/cm2 and 561 ng Au/cm2 deposition) and incubated for 4 h and 24 h. Experiments were repeated six times. The mRNA induction of pro-inflammatory (TNFalpha, IL-8, iNOS) and oxidative stress markers (HO-1, SOD2) was measured, as well as protein induction of pro- and anti-inflammatory cytokines (IL-1, IL-2, IL-4, IL-6, IL-8, IL-10, GM-CSF, TNFalpha, INFgamma). A pre-stimulation with lipopolysaccharide (LPS) was performed to further study the effects of particles under inflammatory conditions. Particle deposition and particle uptake by cells were analyzed by transmission electron microscopy and design-based stereology. A homogeneous deposition was revealed, and particles were found to enter all cell types. No mRNA induction due to particles was observed for all markers. The cell culture system was sensitive to LPS but gold particles did not cause any synergistic or suppressive effects. With this experimental setup, reflecting the physiological conditions more precisely, no adverse effects from gold NPs were observed. However, chronic studies under in vivo conditions are needed to entirely exclude adverse effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neolymphangiogenesis has recently been demonstrated in transplanted kidneys as well as in chronic interstitial nephritis and IgA nephropathy. However, its significance in kidney disease remains to be defined and a systematic study of renal lymphangiogenesis is warranted. We investigated patients with multiple myeloma (MM) presenting in the great majority with acute renal insufficiency. Controls were allograft kidney donors and patients with renal insufficiency due to acute renal failure (ARF). Lymph vessel length density (LVD) was quantified immunohistochemically by means of antipodoplanin staining followed by computer-assisted stereology. The mean LVD in kidneys of patients with MM (23.19 mm(-2)) was higher when compared with allograft donors (7.42 mm(-2), P = 0.0003) and patients with ARF (6.78 mm(-2), P = 0.0002). The higher LVD was significantly associated with interstitial inflammation, and the newly formed lymph vessels were accompanied by diffuse and nodular interstitial infiltrates composed mainly of CD20(+) B cells and CD27(+) plasma cells. The infiltrates in patients with MM also displayed a higher expression of the B-cell chemoattractant CXCL13. These results demonstrate for the first time that lymphangiogenesis is a prominent feature in MM kidneys and that it is associated with a significant accumulation of macrophages, CD20(+) and CD27(+) B lymphocytes. Further studies should clarify whether these changes represent a beneficial or detrimental factor in the progression of the myeloma-related kidney damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study addresses the cellular uptake and intracellular trafficking of 15-nm gold nanoparticles (NPs), either plain (i.e., stabilized with citrate) or coated with polyethylene glycol (PEG), exposed to human alveolar epithelial cells (A549) at the air-liquid interface for 1, 4, and 24 h. Quantitative analysis by stereology on transmission electron microscopy images reveals a significant, nonrandom intracellular distribution for both NP types. No particles are observed in the nucleus, mitochondria, endoplasmic reticulum, or golgi. The cytosol is not a preferred cellular compartment for both NP types, although significantly more PEG-coated than citrate-stabilized NPs are present there. The preferred particle localizations are vesicles of different sizes (<150, 150-1000, >1000 nm). This is observed for both NP types and indicates a predominant uptake by endocytosis. Subsequent inhibition of caveolin- and clathrin-mediated endocytosis by methyl-beta-cyclodextrin (MbetaCD) results in a significant reduction of intracellular NPs. The inhibition, however, is more pronounced for PEG-coated than citrate-stabilized NPs. The latter are mostly found in larger vesicles; therefore, they are potentially taken up by macropinocytosis, which is not inhibited by MbetaCD. With prolonged exposure times, both NPs are preferentially localized in larger-sized intracellular vesicles such as lysosomes, thus indicating intracellular particle trafficking. This quantitative evaluation reveals that NP surface coatings modulate endocytotic uptake pathways and cellular NP trafficking. Other nonendocytotic entry mechanisms are found to be involved as well, as indicated by localization of a minority of PEG-coated NPs in the cytosol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stereology is an essential method for quantitative analysis of lung structure. Adequate fixation is a prerequisite for stereological analysis to avoid bias in pulmonary tissue, dimensions and structural details. We present a technique for in situ fixation of large animal lungs for stereological analysis, based on closed loop perfusion fixation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract We hypothesise that inflammatory response and morphological characteristics of lung parenchyma differ after exposure to short or long multi-walled carbon nanotubes (MWCNT). Mice were subjected to a single dose of vehicle, short or long MWCNT by pharyngeal aspiration. Bronchoalveolar lavage fluid (BALF) obtained at 24 h was analysed for inflammatory reaction and lung tissue was analysed for morphological alterations using stereology. Short MWCNT had stronger potential to induce polymorphonuclear cells whereas long MWCNT increased interleukin-6 levels in BALF. Alveolar septal fibrosis was only observed with short MWCNT. Type II pneumocyte hypertrophy was only detected with long MWCNT. There was no reduction in total alveolar surface area and no sign of type II cell hyperplasia. We observed mild inflammatory and pathological responses to short and long MWCNT in the lung parenchyma depending on the size of the applied MWCNT.