48 resultados para methodology


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pairwise meta-analysis is an established statistical tool for synthesizing evidence from multiple trials, but it is informative only about the relative efficacy of two specific interventions. The usefulness of pairwise meta-analysis is thus limited in real-life medical practice, where many competing interventions may be available for a certain condition and studies informing some of the pairwise comparisons may be lacking. This commonly encountered scenario has led to the development of network meta-analysis (NMA). In the last decade, several applications, methodological developments, and empirical studies in NMA have been published, and the area is thriving as its relevance to public health is increasingly recognized. This article presents a review of the relevant literature on NMA methodology aiming to pinpoint the developments that have appeared in the field. Copyright © 2016 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the ratio of heterophils and lymphocytes (H/L) in response to different stressors is a standard tool for assessing long-term stress in laying hens but detailed information on the reliability of measurements, measurement techniques and methods, and absolute cell counts is often lacking. Laying hens offered different sites of the nest boxes at different ages were compared in a two-treatment crossover experiment to provide detailed information on the procedure for measuring and the difficulties in the interpretation of H/L ratios in commercial conditions. H/L ratios were pen-specific and depended on the age and aviary system. There was no effect for the position of the nest. Heterophiles and lymphocytes were not correlated within individuals. Absolute cell counts differed in the number of heterophiles and lymphocytes and H/L ratios, whereas absolute leucocyte counts between individuals were similar. The reliability of the method using relative cell counts was good, yielding a correlation coefficient between double counts of r > 0.9. It was concluded that population-based reference values may not be sensitive enough to detect individual stress reactions and that the H/L ratio as an indicator of stress under commercial conditions may not be useful because of confounding factors and that other, non-invasive, measurements should be adopted.