50 resultados para comparative study


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The bacterial colonization of the oral mucosa was evaluated in patients with asymptomatic oral lichen planus (OLP) and compared to the microbiologic status in mucosally healthy subjects. Methods: Bacteria from patients with clinically and histopathologically diagnosed OLP from the Stomatology Service, Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, were collected with a non-invasive swab system. Samples were taken from OLP lesions on the gingiva and from non-affected sites on the contralateral side of the mouth. The control population did not have OLP and was recruited from the student clinic. All samples were processed with the checkerboard DNA-DNA hybridization method using well-defined bacterial species for the analysis. Results: Significantly higher bacterial counts of Bacteroides ureolyticus (P = 0.001), Dialister species (sp.) (P = 0.006), Staphylococcus haemolyticus (P = 0.007), and Streptococcus agalactiae (P = 0.006) were found in samples taken from OLP lesions compared to sites with no clinical evidence of OLP. Significantly higher bacterial counts were found for Capnocytophaga sputigena, Eikenella corrodens, Lactobacillus crispatus, Mobiluncus curtisii, Neisseria mucosa, Prevotella bivia, Prevotella intermedia, and S. agalactiae at sites with lesions in subjects with OLP compared to sites in control subjects (P <0.001). Conclusions: Microbiologic differences were found between sites with OLP and sites in subjects without a diagnosis of OLP. Specifically, higher counts of staphylococci and S. agalactiae were found in OLP lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three biphasic calcium phosphate (BCP) bone substitute materials with hydroxyapatite (HA)/tricalcium phosphate (TCP) ratios of 20/80, 60/40, and 80/20 were compared to coagulum, particulated autogenous bone, and deproteinized bovine bone mineral (DBBM) in membrane-protected bone defects. The defects were prepared in the mandibles of 24 minipigs that were divided into four groups of six with healing times of 4, 13, 26, and 52 weeks, respectively. The histologic and histomorphometric evaluation focused on differences in amount and pattern of bone formation, filler degradation, and the interface between bone and filler. Collapse of the expanded polytetrafluoroethylene barrier membrane into the coagulum defects underlined the necessity of a filler material to maintain the augmented volume. Quantitatively, BCP 20/80 showed bone formation and degradation of the filler material similar to autografts, whereas BCP 60/40 and BCP 80/20 rather equaled DBBM. Among the three BCP's, the amount of bone formation and degradation of filler material seemed to be inversely proportional to the HA/TCP ratio. The fraction of filler surface covered with bone was highest for autografts at all time points and was higher for DBBM than BCP 80/20 and 60/40 at the early healing phase. TRAP-positive multinucleated cells were identified on BCP and DBBM surfaces without showing typical signs of resorption lacunae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. METHODS: Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10,000 insertion-separation cycles. RESULTS: Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. CONCLUSIONS: Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To show the relationship between the neuropeptide-Y pelvic sympathetic nerves and neoangiogenesis in the development of endometriosis DESIGN: Prospective study. SETTING: Academic community teaching hospital. PATIENTS: Fifteen consecutive women with unilateral endometriotic infiltration of the sacrouterine ligaments. INTERVENTIONS: A laparoscopic excision/biopsy of involved and noninvolved parts of the sacrouterine ligaments were taken. The sections were incubated with the neuronal marker rabbit polyclonal anti-protein gene product 9.5 and rabbit polyclonal anti-neuropeptide-Y. We made a comparative study on the distribution of nerve fibers and their relationship to the vessels on intact and endometriotic involved tissue. MEASUREMENTS AND MAIN RESULTS: The results show that a large amount of nerves are present around the blood vessels in the endometriosis samples, and a large number of these nerves are neuropeptide-Y sympathetic nerves. Adrenergic fibers are also present in the intact control subjects, however, in significantly smaller amounts. CONCLUSION: This finding shows a strong relationship between the neuropeptide-Y sympathetic pelvic nerves and the neoangiogenesis required for the development of endometriosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to assess the clinical relevance of a slice-to-volume registration algorithm, this technique was compared to manual registration. Reformatted images obtained from a diagnostic CT examination of the lower abdomen were reviewed and manually registered by 41 individuals. The results were refined by the algorithm. Furthermore, a fully automatic registration of the single slices to the whole CT examination, without manual initialization, was also performed. The manual registration error for rotation and translation was found to be 2.7+/-2.8 degrees and 4.0+/-2.5 mm. The automated registration algorithm significantly reduced the registration error to 1.6+/-2.6 degrees and 1.3+/-1.6 mm (p = 0.01). In 3 of 41 (7.3%) registration cases, the automated registration algorithm failed completely. On average, the time required for manual registration was 213+/-197 s; automatic registration took 82+/-15 s. Registration was also performed without any human interaction. The resulting registration error of the algorithm without manual pre-registration was found to be 2.9+/-2.9 degrees and 1.1+/-0.2 mm. Here, a registration took 91+/-6 s, on average. Overall, the automated registration algorithm improved the accuracy of manual registration by 59% in rotation and 325% in translation. The absolute values are well within a clinically relevant range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comparison between an unconstrained and a partially constrained system for in vitro biomechanical testing of the L5-S1 spinal unit was conducted. The objective was to compare the compliance and the coupling of the L5-S1 unit measured with an unconstrained and a partially constrained test for the three major physiological motions of the human spine. Very few studies have compared unconstrained and partially constrained testing systems using the same cadaveric functional spinal units (FSUs). Seven human L5-S1 units were therefore tested on both a pneumatic, unconstrained, and a servohydraulic, partially constrained system. Each FSU was tested along three motions: flexion-extension (FE), lateral bending (LB) and axial rotation (AR). The obtained kinematics on both systems is not equivalent, except for the FE case, where both motions are similar. The directions of coupled motions were similar for both tests, but their magnitudes were smaller in the partially constrained configuration. The use of a partially constrained system to characterize LB and AR of the lumbosacral FSU decreased significantly the measured stiffness of the segment. The unconstrained system is today's "gold standard" for the characterization of FSUs. The selected partially constrained method seems also to be an appropriate way to characterize FSUs for specific applications. Care should be taken using the latter method when the coupled motions are important.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent reports indicate that cytotoxic T cells are critically involved in contact hypersensitivity reactions in animals. In this study we sought to investigate the in vivo expression of cytotoxic granule proteins in the elicitation phase of allergic contact dermatitis in humans. Skin biopsy specimens were obtained from patients with allergic contact dermatitis (n = 8) and psoriasis (n = 6) and from controls with normal skin (n = 6). Expression of perforin and granzyme B was investigated by in situ hybridization and immunohistochemistry. In contrast to normal skin and psoriasis, a significant enhancement of perforin and granzyme B gene expression and immunoreactivity was observed in the mononuclear cell infiltrate of allergic contact dermatitis. Immunoreactivity for perforin and granzyme B was mainly found in the cytoplasm of lymphocytic cells, which were located in the dense perivascular infiltrate as well as at sites of marked spongiosis in the epidermis. Double immunostaining revealed that both CD4+ and CD8+ T cells are capable of expressing perforin and granzyme B. In conclusion, our data suggest that T-cell-mediated mechanisms involving cytotoxic granule proteins may elicit epidermal cell injury in vivo and thereby strongly contribute to the development of allergic contact dermatitis in humans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this retrospective study was to compare patterns of vertebral fractures and luxations in 42 cats and 47 dogs, and to evaluate the impact of species-related differences on clinical outcome. Data regarding aetiology, neurological status, radiographic appearance and follow-up were compared between the groups. The thoracolumbar (Th3-L3) area was the most commonly affected location in both cats (49%) and dogs (58%). No lesions were observed in the cervical vertebral segments in cats, and none of the cats showed any signs of a Schiff-Sherrington syndrome. Vertebral luxations were significantly more frequent in dogs (20%) than in cats (6%), whereas combined fracture-luxations occurred significantly more often in cats (65%) than in dogs (37%). Caudal vertebral segment displacement was mostly dorsal in cats and ventral in dogs, with a significant difference in direction between cats and large dogs. The clinical outcome did not differ significantly between the two populations, and was poor in most cases (cats: 61%; dogs: 56%). The degree of dislocation and axis deviation were both significantly associated with a worse outcome in dogs, but not in cats. Although several differences in vertebral fractures and luxation patterns exist between cats and dogs, these generally do not seem to affect outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Thermal Nd:YAG laser energy is well known for the purpose of blood coagulation. However, little is known about the bleeding frequency following laser-assisted oral surgery in patients on coumarin drugs. Therefore, the purpose of this study was to compare retrospectively the frequency of bleeding complications following Nd:YAG laserassisted versus conventional local coagulation of blood in oral surgery. METHOD AND MATERIALS In October 2002, minor oral surgical interventions were found to be indicated in a total of 45 cardiac risk patients. In Group 1, blood coagulation was yielded in 24 patients with a Nd:YAG laser system, whereas in Group 2, treatment was performed in 21 patients with conventional means of local hemostasis. All therapies were performed continuing anticoagulant therapy between November 2002 and March 2003. Clinical data were recorded retrospectively from patient charts in May 2007. RESULTS In both Groups 1 and 2, a total of two bleeding complications were recorded. However, local re-interventions were sufficient for local hemostasis. CONCLUSION These results indicate that Nd:YAG laser-assisted local hemostasis was not able to prevent bleeding complications completely. Within the limitations of this retrospective study it was concluded that in patients with anticoagulant treatment undergoing minor oral surgery, Nd:YAG laser-assisted local hemostasis is not superior to conventional methods of blood coagulation with respect to the frequency of bleeding complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Robotic exoskeletons can be used to study and treat patients with neurological impairments. They can guide and support the human limb over a large range of motion, which requires that the movement trajectory of the exoskeleton coincide with the one of the human arm. This is straightforward to achieve for rather simple joints like the elbow, but very challenging for complex joints like the human shoulder, which is comprised by several bones and can exhibit a movement with multiple rotational and translational degrees of freedom. Thus, several research groups have developed different shoulder actuation mechanism. However, there are no experimental studies that directly compare the comfort of two different shoulder actuation mechanisms. In this study, the comfort and the naturalness of the new shoulder actuation mechanism of the ARMin III exoskeleton are compared to a ball-and-socket-type shoulder actuation. The study was conducted in 20 healthy subjects using questionnaires and 3D-motion records to assess comfort and naturalness. The results indicate that the new shoulder actuation is slightly better than a ball-and-socket-type actuation. However, the differences are small, and under the tested conditions, the comfort and the naturalness of the two tested shoulder actuations do not differ a lot.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The practice of information systems (IS) outsourcing is widely established among organizations. Nonetheless, evidence suggests that organizations differ considerably in the extent to which they deploy IS outsourcing. This variation has motivated research into the determinants of the IS outsourcing decision. Most of this research is based on the assumption that a decision on the outsourcing of a particular IS function is made independently of other IS functions. This modular view ignores the systemic nature of the IS function, which posits that IS effectiveness depends on how the various IS functions work together effectively. This study proposes that systemic influences are important criteria in evaluating the outsourcing option. It further proposes that the recognition of systemic influences in outsourcing decisions is culturally sensitive. Specifically, we provide evidence that systemic effects are factored into the IS outsourcing decision differently in more individualist cultures than in collectivist ones. Our results of a survey of United States and German firms indicate that perceived in-house advantages in the systemic impact of an IS function are, indeed, a significant determinant of IS outsourcing in a moderately individualist country (i.e., Germany), whereas insignificant in a strongly individualist country (i.e., the United States). The country differences are even stronger with regard to perceived in-house advantages in the systemic view of IS professionals. In fact, the direction of this impact is reversed in the United States sample. Other IS outsourcing determinants that were included as controls, such as cost efficiency, did not show significant country differences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine besnoitiosis is considered an emerging chronic and debilitating disease in Europe. Many infections remain subclinical, and the only sign of disease is the presence of parasitic cysts in the sclera and conjunctiva. Serological tests are useful for detecting asymptomatic cattle/sub-clinical infections for control purposes, as there are no effective drugs or vaccines. For this purpose, diagnostic tools need to be further standardized. Thus, the aim of this study was to compare the serological tests available in Europe in a multi-centred study. A coded panel of 241 well-characterized sera from infected and non-infected bovines was provided by all participants (SALUVET-Madrid, FLI-Wusterhausen, ENV-Toulouse, IPB-Berne). The tests evaluated were as follows: an in-house ELISA, three commercial ELISAs (INGEZIM BES 12.BES.K1 INGENASA, PrioCHECK Besnoitia Ab V2.0, ID Screen Besnoitia indirect IDVET), two IFATs and seven Western blot tests (tachyzoite and bradyzoite extracts under reducing and non-reducing conditions). Two different definitions of a gold standard were used: (i) the result of the majority of tests ('Majority of tests') and (ii) the majority of test results plus pre-test information based on clinical signs ('Majority of tests plus pre-test info'). Relative to the gold standard 'Majority of tests', almost 100% sensitivity (Se) and specificity (Sp) were obtained with SALUVET-Madrid and FLI-Wusterhausen tachyzoite- and bradyzoite-based Western blot tests under non-reducing conditions. On the ELISAs, PrioCHECK Besnoitia Ab V2.0 showed 100% Se and 98.8% Sp, whereas ID Screen Besnoitia indirect IDVET showed 97.2% Se and 100% Sp. The in-house ELISA and INGEZIM BES 12.BES.K1 INGENASA showed 97.3% and 97.2% Se; and 94.6% and 93.0% Sp, respectively. IFAT FLI-Wusterhausen performed better than IFAT SALUVET-Madrid, with 100% Se and 95.4% Sp. Relative to the gold standard 'Majority of test plus pre-test info', Sp significantly decreased; this result was expected because of the existence of seronegative animals with clinical signs. All ELISAs performed very well and could be used in epidemiological studies; however, Western blot tests performed better and could be employed as a posteriori tests for control purposes in the case of uncertain results from valuable samples.