161 resultados para Endoscopic Retrograde Cholangiopancreatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stent graft-induced retrograde type A dissection is a life-threatening complication after endovascular treatment of acute aortic type B dissections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this multicentre study was to systematically analyse the strengths and weaknesses in the surgical training for endoscopic sinus surgery (ESS) and identify measures that may improve training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past decades, endoscopic mucosal resection (EMR) has been developed to treat early intramucosal esophageal cancers and dysplastic Barrett's esophagus. The primary drawback of this method is severe postsurgical esophageal stricture formation. The purpose of this preclinical study was to assess strategies for prevention of this major complication by injecting autologous keratinocytes in the EMR mucosal defect in the sheep model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limitations associated with the visual information provided to surgeons during laparoscopic surgery increases the difficulty of procedures and thus, reduces clinical indications and increases training time. This work presents a novel augmented reality visualization approach that aims to improve visual data supplied for the targeting of non visible anatomical structures in laparoscopic visceral surgery. The approach aims to facilitate the localisation of hidden structures with minimal damage to surrounding structures and with minimal training requirements. The proposed augmented reality visualization approach incorporates endoscopic images overlaid with virtual 3D models of underlying critical structures in addition to targeting and depth information pertaining to targeted structures. Image overlay was achieved through the implementation of camera calibration techniques and integration of the optically tracked endoscope into an existing image guidance system for liver surgery. The approach was validated in accuracy, clinical integration and targeting experiments. Accuracy of the overlay was found to have a mean value of 3.5 mm ± 1.9 mm and 92.7% of targets within a liver phantom were successfully located laparoscopically by non trained subjects using the approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pneumatic balloon dilation and surgical myotomy are the most effective treatments for achalasia. While there is controversy which method is best, the aim of the current study was to identify predictors of symptom recurrence after endoscopic or surgical therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whether total extraperitoneal inguinal hernia repair (TEP) is associated with worse outcomes than transabdominal preperitoneal inguinal hernia repair (TAPP) continues to be a matter of debate. The objective of this large cohort study is to compare outcomes between patients undergoing TEP or TAPP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONCLUSION: Endoscopic resection of laryngeal and tracheal lesions using the microdebrider is a safe, accurate and reliable method. OBJECTIVE: The microdebrider is an important tool for endoscopic nasal and sinus surgery and over the last few years a powered blade with a long shaft has been developed for endoscopic laryngeal and tracheal surgery. The aim of this non-randomized prospective study was to determine the advantages and disadvantages of the microdebrider for treating patients with different laryngeal and tracheal pathologies. MATERIAL AND METHODS: The laryngeal microdebrider was used under endoscopic control in 37 patients. In 29 cases a benign laryngeal lesion was removed endoscopically. In four patients debulking of a malignant obstructive endolaryngeal tumor was performed in order to avoid a tracheotomy. In four cases a bulky obstructing endotracheal lesion was removed. RESULTS: All laryngotracheal lesions could be removed, and this was facilitated by the use of angled rigid telescopes and the laryngeal blade. No traumatic lesions to normal laryngeal tissue occurred as a result of use of the microdebrider and no postoperative endolaryngeal bleeding was observed. The histological diagnosis of the biopsies taken with the microdebrider was accurate in every case. In three of the four cases with obstructive laryngeal malignancies, a tracheotomy was avoided until definitive therapy was undertaken. Normal breathing was restored in all patients with endotracheal lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Preoperative chemoradiotherapy is generally recommended for locally advanced esophageal cancer (clinical stage T3 or T4 or nodal positive disease) but not for early cancer (clinical stage T0 to T2, N0). EUS has been described as the most accurate method to distinguish between early and locally advanced stage in several studies. Recently however, the high accuracy of EUS (90% or higher) was questioned by some investigators. This raises the issue whether the results of studies focused on EUS accuracy may be directly translated into daily clinical practice. Aim & Methods: The aim of this retrospective analysis was to assess the accuracy of preoperative EUS to distinguish between early and locally advanced esophageal cancer in daily clinical practice outside a study setting. EUS was performed by several investigators, including trainees in one university hospital. For this purpose, EUS reports and patient files (medical and surgical) including histological reports of 300 consecutive pts with esophageal tumors were reviewed. In pts with adenocarcinoma or squamous cell cancer and surgical resection without previous radio-/chemotherapy, EUS tumor staging was compared with histological diagnosis. Results: Out of the 300 consecutive pts with esophageal tumor and EUS 102 pts had esophageal surgery after EUS-staging without any radio-/chemotherapy. In 93 pts oesophageal cancer was confirmed, whereas 9 had other tumors. The mean age was 65 years (range 27-89), sex ratio female:male was 1:3.2. To distinguish between early and late tumor stage, the accuracy was 85%. The sensitivity and specificity for early cancer was 59%, and 93%, respectively. The diagnostic accuracy for local tumor spread was 90%, 90%, 68%, 69%, 89% for pT0, pT1, pT2, pT3 and pT4 lesions, respectively. The overall accuracy for T-stage was 74%. For pN-positive staging the accuracy of EUS was 73%. Conclusion: In daily clinical practice, the accuracy of EUS in assessing esophageal tumor staging is lower than in specific studies focusing on EUS accuracy. Mainly early esophageal cancer stages were overstaged. Thus, the implementation of recommendations for diagnostic work-up of esophageal cancer patients resulting from highly specific studies should consider the appropriate clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Insertion of percutaneous endoscopic gastrostomies (PEG) in patients on chronic peritoneal dialysis (PD) has been reported to be contraindicated due to an increased risk of morbidity and mortality. However, no systematic survey on this topic has yet been published. DESIGN: Retrospective multicenter study. SETTING: 23 pediatric dialysis units associated with the working group Arbeitsgemeinschaft für Pädiatrische Nephrologie (APN). DATA SOURCE: A structured questionnaire on clinical details of PD patients who had undergone PEG insertion or open gastrostomy (OG) since 1994 was distributed to all pediatric dialysis units of the APN. RESULTS: 27 PD patients (20 males) from 12 centers in whom PEG insertion was performed after Tenckhoff catheter introduction were evaluated. Age at intervention ranged from 0.25 to 10.9 years (median 1.3 years). Most patients were malnourished, with standard deviation score (SDS) for body weight between -4.2 and -0.6 (median -2.2). Major complications were early peritonitis < 7 days after PEG in 10/27 (37%) patients, episodes of fungal peritonitis in 7/27 (26%) patients, 4 cessations of PD and change to hemodialysis, and 2 associated deaths. However, in 14 patients, no such problems were encountered and, in 4 patients, early peritonitis effectively treated with intraperitoneal antibiotics was the only major complication. Thus, in 18/27 (67%) patients, PD was successfully reinitiated shortly after PEG insertion. Among all participating centers, only two OG procedures were reported during the study period, illustrating a clear preference for the PEG over the OG procedure among members of the APN. CONCLUSION: PEG insertion following PD initiation carries a high risk for fungal peritonitis and potential PD failure; however, complication rates in this largest reported series were lower than previously described. Antibiotic and antifungal prophylaxis, withholding PD for 2 - 3 days, and gastrostomy placement by an experienced endoscopy team are suggested precautions for lowering the risk of associated complications. When gastrostomy placement does not occur prior to or at the time of initiating PD, the risks and benefits of percutaneous versus open placement must be carefully weighed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To demonstrate the safety and feasibility of a new concept for CTO recanalization using a controlled antegrade and retrograde subintimal tracking technique (CART technique). BACKGROUND: A successful percutaneous recanalization of chronic coronary occlusions results in improved survival, as well as enhanced left ventricular function, reduction in angina, and improved exercise tolerance. However, successful recanalization of CTOs is still not optimal, and needs further improvements. METHODS: Ten patients with a CTO underwent the CART procedure. This technique combines the simultaneous use of the antegrade and retrograde approaches. A subintimal dissection is created antegradely and retrogradely, which allows the operator to limit the extension of the subintimal dissection in the CTO portion. A retrograde approach means that the occlusion site is approached in a retrograde fashion through the best collateral channel from any other patent coronary artery. RESULTS: The occlusion site was located in the RCA in 9 patients, and in the LAD in 1 patient. CTO duration varied from 7 to 84 months. Vessel recanalization was achieved in all patients. In all cases, the subintimal dissection was limited to the CTO region. No complications occurred in the collateral channel used for the retrograde approach. There were no in-hospital major adverse cardiac events. CONCLUSIONS: The CART technique is feasible, safe, and has a high success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a standardized procedure for examination of the canine abdomen using endoscopic ultrasound and to describe the organs and structures that could be identified transgastrically. The abdomen of four healthy dogs and two cadavers were examined with endoscopic ultrasound. Five anatomic landmarks were used for standardized imaging of the cranial abdomen. These were the portal vein, splenic head and body, duodenum, left kidney, and aorta. High-resolution images of the following organs and structures could be made: distal esophagus, gastric wall from the cardia to the pylorus, liver, caudal vena cava, hepatic lymph nodes, liver hilus, and associated vessels, trifurcation of the celiac artery as well as the path of its branches and the left pancreatic limb and body. Structures that were more difficult to image were the distal duodenum and right pancreatic limb, the entire jejunum, ileum, and cecum as well as the tail of the spleen. Endoscopic ultrasound allowed excellent visualization of the gastric wall and regional structures without interference with gas artefacts. Centrally located organs such as the pancreas could be well examined transgastrically with endoscopic ultrasound without interference by overlying intestinal segments as is common with transabdominal ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Although endoscopic scoring of the tracheal septum thickness is used as a diagnostic tool for evaluation of lower airway disease, its clinical relevance and reliability have never been critically assessed in the horse. OBJECTIVES: To investigate if septum thickness scores (STS) are reliable and serve as a clinically useful indicator of lower airway disease status and/or inflammation. METHODS: The variance of STS attributable to the horse, observer and changes over time was determined. The distribution of STS in a population of clinically normal horses and correlations of STS with age, gender, as well as mucus accumulation and cell differentials of tracheobronchial secretions and bronchoalveolar lavage fluid were investigated. Effects of altered pulmonary ventilation, induced by different drugs, on STS were assessed. Finally, STS of horses affected with recurrent airway obstruction (RAO) were compared to those of clinically normal horses. RESULTS: Recorded STS showed excellent intra- and satisfactory interobserver agreement Established clinical, endoscopic and cytological measures of lower airway inflammation, i.e. mucus accumulation scores and airway neutrophilia, did not correlate with STS. In horses age > or = 10 years, septum scores were significantly higher (P = 0.022) than in younger horses. Septum thickness scores did not differ significantly between clinically normal and RAO-affected horses both in exacerbation and in remission. Horses with markedly increased breathing effort (i.e. with metacholine- or lobeline hydrochloride-challenge), often differed markedly (up to 1.9 scores), but the average of end-inspiratory and end-expiratory STS did not differ from baseline STS. CONCLUSIONS AND CLINICAL RELEVANCE: Endoscopic STS are a reproducible measure, but STS did not correlate with clinical, endoscopic and cytological findings indicative of RAO or inflammatory airway disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soon after its introduction in 1991, MR cholangiopancreatography has become an established diagnostic tool for the evaluation of the pancreaticobiliary ductal system at a field strength of 1.5T. It remains unclear whether MR cholangiopancreatography performed at 3T will benefit from the higher magnetic field strength or whether a field strength of 1.5T should continue to be considered the gold standard for MR cholangiopancreatography. This article reviews the current literature on the benefits and drawbacks of MR cholangiopancreatography at 3T compared with a standard field strength of 1.5T. Field strength-related artifacts that affect MR cholangiopancreatography at 3T also are discussed.