4 resultados para Bovine, Bone histomorphometry, Mechanical stability, Endochondral ossification

em AMS Tesi di Dottorato - Alm@DL - Università di Bologna


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Akt (also called PKB) is a 63 kDa serine/threonine kinase involved in promotion of cell survival, proliferation a nd metabolic responses downstream the phosphoinositide-3-kinase (PI 3-kinase) signaling pathway. In resting cells, Akt is a predominantly cytosolic enzyme; however generation of PI 3-kinase lipid products recruits Akt to the plasma membrane, resulting in a conformational change which confers full enzymatic activity through the phosphorylation of the membrane-bound protein at two residues, Thr308, and Ser473. Activated Akt redistributes to cytoplasm and nucleus, where phosphorylation of specific substrates occurs. Both the presence and the activity of Akt in the nucleus have been described. An interesting mechanism that mediates nuclear translocation of Akt has been described in human mature T-cell leukemia: the product of TCL1 gene, Tcl1, interacts with the PH domain of phosphorylated Akt, thus driving Akt to the nucleus. In this context, Tcl1 may act as a direct transporter of Akt or may contribute to the formation of a complex that promotes the transport of active Akt to the nucleus, where it can phosphorylate nuclear substrates. A well described nuclear substrate if Foxo. IGF-1 triggers phosphorylation of Foxo by Akt inside the nucleus, where phospho-Foxo associates to 14.3.3 proteins that, in turn, promote its export to the cytoplasm where it is sequestered. Remarkably, Foxo phosphorylation by Akt has been shown to be a crucial event in Akt-dependent myogenesis. However, most Akt nuclear substrates have so far remained elusive, as well as nuclear Akt functions. This lack of information prompted us to undertake a search of substrates of Akt in the nucleus, by the combined use of 2D-separation/mass spectrometry and anti-Akt-phosphosubstrate antibody. This study presents evidence of A-type lamins as novel nuclear substrates of Akt. Lamins are type V intermediate filaments proteins found in the nucleus of higher eukaryotes where, together with lamin-binding proteins, they form the lamina at the nuclear envelope, providing mechanical stability for the nuclear membrane. By coimmunoprecipitation, it is demonstrated here that endogenous lamin A and Akt interact, and that A-type lamins are phosphorylated by Akt both in vitro and in vivo. Moreover, by phosphoaminoacid analysis and mutagenesis, it is further demonstrated that Akt phosphorylates lamin A at Ser404, and, more importantly, that while lamin A/C phosphorylation is stable throughout the cell cycle, phosphorylation of the precursor prelamin A becomes detectable as cells enter the G2 phase, picking at G2/M. This study also shows that lamin phosphorylation by Akt creates a binding site for 14.3.3 adaptors which, in turn, promote prelamin A degradation. While this mechanism is in agreement with a general role of Akt in the regulation of a subset of its substrates, opposite to what has been described, degradation is not mediated through a ubiquitination and proteasomal mechanism but through a lysosomal pathway, as indicated by the reverting action of the lysosomal inhibitor cloroquine. Phosphorylation is a key event in the mitotic breakdown of the nuclear lamina. However, the kinases and the precise sites of phosphorylation are scarcely known. Therefore, these results represent an important breakthrough in this very significant but understudied area. The phosphorylation of the precursor protein prelamin A and its subsequent degradation at G2/M, when both the nuclear envelop and the nuclear lamina disassemble, can be view as part of a mechanism to dispose off the precursor that is not needed in this precise context. The recently reported finding that patients affected by Emery-Dreifuss muscular dystrophy carry a mutation at Arg 401, in the Akt phosphorylation motif, open new perspective that warrant further investigation in this very important field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lo scopo di questa tesi è stato la produzione di un elettrolizzatore ad ossidi solidi (SOEC) mediante tecniche economiche e facilmente industrializzabili. Fondamentale a questo scopo è stata la realizzazione di una semicella costituita da un anodo poroso a base di La0.8Sr0.2MnO3-Ce0.8Gd0.2O2-δ (LSM-GDC) ed un elettrolita denso a base di Ce0.8Gd0.2O2-δ (GDC). Le tecniche utilizzate per la produzione di questo sistema sono state il colaggio su nastro e la serigrafia. Anche se generalmente, le celle SOEC vengono prodotte catodo supportate, in questo studio, l’elemento supportante scelto è stato l’anodo poiché questo garantisce una migliore stabilità meccanica all’intera cella. Tale substrato è stato ottenuto mediante colaggio su nastro accoppiato con un metodo innovativo di sinterizzazione denominato sinterizzazione reattiva, processo che prevede la formazione della fase di interesse durante un unico trattamento termico di eliminazione degli additivi organici e consolidamento del manufatto finale. La membrana elettrolitica per l’ottenimento del bilayer anodo-elettrolita, è stata prodotta mediante sia serigrafia che colaggio su nastro. L’accurato studio dell’evoluzione di fase della polvere anodica, l’ottimizzazione della sospensione per colaggio su nastro e dei trattamenti termici hanno permesso l’ottenimento di anodi (fino a dimensioni di 10x10 cm2). Lo studio dei profili di sinterizzazione delle polveri anodica ed elettrolitica e dell’influenza della tecnica di formatura sulla sinterabilità dei layer elettrolitici prodotti hanno inoltre permesso l’ottenimento di una semicella planare costituita da un elettrodo poroso ed una membrana elettrolitica densa adatte per applicazioni SOEC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present thesis illustrates the research carried out during the PhD studies in Bioengineering. The research was aimed to characterise the human bone tissue, with particular regard to the differences between cortical and trabecular bone. The bone tissue characteristics that affect its mechanical properties were verified or identified, using an experimental approach, to corroborate or refute hypotheses based on the state of the art in bone tissue biomechanics. The studies presented in the present PhD thesis were designed to investigate aspects of bone tissue biomechanics, which were in need of a more in-depth examination since the data found in the literature was contradictory or scarce. In particular, the work was focalised on the characterisation of the basic structure of the bone tissue (groups of lamellae), its composition, its spatial organisation (trabecular bone microarchitecture) and their influence on the mechanical properties. In conclusion, the present thesis integrates eight different studies on the characterisation of bone tissue. A more in-depth examination of some of the aspects of bone tissue biomechanics where the data found in the literature was contradictory or scarce was performed. Bone tissue was investigated at several scales, from its composition up to its spatial organization, to determine which parameters influence the mechanical behaviour of the tissue. It was found that although the composition and real density of bone tissue are similar, the differences in structure at different levels cause differences between the two types of bone tissue (cortical and trabecular) in mechanical properties. However, the apparent density can still be considered a good predictor of the mechanical properties of both cortical and trabecular bone. Finally, it was found that the bone tissue characteristics might change when a pathology is present, as demonstrated for OA.