1 resultado para secuencias de inserción
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The rehabilitation with mandibular distal extension removable partial dentures (DERPD) is complex and the use of implants has been improving the functioning of this approach. The insertion bony level around of the last support tooth is an aggravating factor, since it can harm the longevity of the treatment. Thus, the aim of this research was to evaluate the displacement tendency of a mandibular DERPD associated to an implant, with different insertion bony levels and different connections between the RPD and the support tooth, by finite element analysis. Eight models were made: MA - DERPD, incisal rest, no bony loss; MB - DERPD, distal plate, no bony loss; MC - DERPD, incisal rest, no bony loss, with implant and ERA system; MD - DERPD, distal plate, no bony loss, with implant and ERA system; ME - DERPD, incisal rest, bony loss; MF - DERPD, distal plate, bony loss; MG - DERPD, incisal rest, bony loss, with implant and ERA system; MH - DERPD, distal plate, bony loss, with implant and ERA system. Loads of 50 N in each peak were applied. Displacement maps were obtained and showed that implant favors this association and the bony loss harms the prognostic of the prosthesis. It is concluded that: the introduction of the implant with ERA system reduced the displacement tendency of the tooth and supporting structures; introduction of distal plate reduced the movement tendency of the support tooth; the decrease of the periodontal support didn't influence significantly the displacement tendency of the models with distal plate distal, but it influenced the models with distal incisal rest.