96 resultados para fracture

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed to obtain quantitative information about grain size and shape from fractured surfaces of ceramic materials. One elaborated a routine to split intergranular and transgranular grains facets of ceramic fracture surfaces by digital image processing. A commercial ceramic (ALCOA A-16, Al2O3-1.5% of CrO) was used to test the proposed method. Microstructural measurements of grain shape and size taken from fracture surfaces have been compared through descriptive statistics of distributions, with the corresponding measurements from polished and etched surfaces. The agreement between results, with the expected bias on grain size values from fractures, obtained for both types of surfaces allowed to infer that this new technique can be used to extract the relevant microstructural information from fractured surfaces, thus minimising the time consuming steps of sample preparation. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatigue, corrosion and wear resistance are important parameters in aircraft components development as landing gear. High strength/weight ratio and effective corrosion resistance make of titanium alloys an alternative choice to replace steel and aluminum alloys. However, titanium alloys have poor tribological properties, which reduce devices performance under friction. PVD coatings tribological systems has been increased due to their attractive mechanical properties as low environmental impact, low friction coefficient, low wear rate and hardness up to 2000 HV.In this study the influence of TiN deposited by PVD on the fatigue strength of Ti-6Al-4V alloy was evaluated. Comparison of fatigue strength of coated specimens and base material shows also a decrease when parts are coated. It was observed that the influence is more significant in high cycle fatigue tests. Scanning electron microscopy technique (SEM) was used to observe crack origin sites and fracture features. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. The postoperative acute renal failure (ARF) incidence in different kinds of surgery has rarely been studied. Age, cardiac dysfunction, previous renal dysfunction, intraoperative hypoperfusion, and use of nephrotoxic medications are mentioned as risk factors for ARF at the postoperative period. The postoperative ARF definition was based on the creatinine increase by the RIFLE classification (R = risk, I = injury, F = failure, L = loss, E = end stage), which corresponds to a 1.5 creatinine increase, two to three times, respectively, above the basal value. This study aimed to evaluate the postoperative ARF incidence in elderly patients who underwent femur fracture surgery under subarachnoid anesthesia and stratify it by the RIFLE criteria. Methods. Ninety patients older than 65 years under spinal anesthesia with fixed dosage of 15 mg of 0.5% isobaric bupivacaine associated with morphine 50 g were studied. Immediate postoperative creatinine was considered basal and compared with maximal creatinine evaluated at 24, 48, and 72 postoperative hours. Results. The mean age of the patients was 80.27 years. ARF incidence was 24.44% and stratified this way: R = 21.11% and I = 3.33%. Conclusions. In conclusion, the postoperative ARF incidence after femur fracture surgery in patients over 65 years was 24.44%. By analyzing the stratification based on the RIFLE classification, the incidence was categorized as Risk (R) = 21.11% and Injury (I) = 3.33%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A boa constrictor was presented with a short oblique compound fracture of the rostral third of the right maxilla. The fracture was reduced and biomaterial was placed around the fracture. A computed tomography scan at 1.5 mo post-surgery showed that the fracture had healed with slight displacement of the bone fragments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was m adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through 1 bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increased incidence of traumatic injuries to anterior teeth is a consequence of leisure activities, where the most common injuries are crown fractures. Treatment of the dental trauma is complex and requires a comprehensive and accurate diagnostic and treatment plan. It is also important to consider the biological, functional, esthetic and economic aspects, as well as the patient's desire. The purpose of this article is to report a case that shows the multidisciplinary approach required to successfully manage the rehabilitation of a maxillary central incisor with a complex crown fracture and a maxillary lateral incisor, that at first presented an oblique crown-root fracture, and after the orthodontic extrusion, suffered a more apical new crown-root fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic injuries treatment of the fronto-naso-orbito-ethmoidal region has been one of the most challenging treatments within maxillofacial surgery, particularly of extensive orbital defects, very common in this type of pathologic condition. A 48-year-old man involved in a car collision presented an extensive bilateral fracture of the orbit medial wall, nasal bones, the nasal septum, and the frontal anterior table. The clinical and tomographic findings concluded the diagnosis of a maxilla and fronto-naso-orbito-ethmoidal fracture. Among the variety of biomaterials, the titanium mesh was elected because of the extension and magnitude of the bone defect, obtaining this way esthetic and functional results with better prognosis.