21 resultados para CFD

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a computational fluid dynamics (CFD) application about the axial fan design used in an agricultural spraying system with a theoretical and experimental analysis of comparative results between the characteristic curves of a fan for several rotations and numerical results for the influence of blade attack angle variation and optimization of the spraying system, both for a same rotation. Flow was considered three-dimensional, turbulent, isothermal, viscous and non-compressible in a steady state, disregarding any influence of the gravity field. The average turbulent field was obtained from the application of time average where the turbulence model required for closing the set of equations was the k-E model. Resolution of all connected phenomena was achieved with the help of a fluid dynamics computer, CFX, which uses the finite volumes technique as a numerical method. In order to validate the theoretical analysis, an experiment was conducted in a circular section of a horizontal wind tunnel, using a Pitot tube for pressure readings. The main results demonstrate that the methodology used, based on CFD techniques, is able to reproduce the phenomenological behavior of an axial fan in a spraying system because results were very reliable and similar to experimentally measured ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of nicosulfuron on morphological, yield and growth characteristics and the histological modifications in the leaf blade were evaluated for eight corn cultivars: landrace popcorn, ESALQ-popcorn, Piranao, DSCC-Architecture, ESALQ VF7, ESALQ VD8, JAB 01F and JAB 02D. The experimental de sign was a randomized complete block with three replications in a factorial arrangement. Plots were four rows wide and 6.00m long with 0.90m spacing between rows and 0.20m between plants. Nicosulfuron was applied at the dose of 160 g a.i.ha(-1), when the plants was 25 cm high and has 5-6 expanded leaves. Nicosulfuron significantly reduced plant height at silking and the Final plant stand. There was also a significant reduction for plant height at 47 clays after sowing, for number of leaves, ear position. ear height, grain yield, ear weight and total number of ears due to nicosulfuron. The cultivars JAB 01 and JAB 02 were the least affected by the herbicide with similar yields to those of the control group, showing good tolerance to nicosulfuron. The leaves injury symptoms for all the studied cultivars consisted of chlorosis and puckering of the blades from the expanding central leaves of the plant at 7 days after application. Anatomical alterations in the epidermis due to the herbicide consisted of an increase in number and size of the bulliform cells and in the suppression of the epidermal cells in the epidermis and in the nearby of the vascular bundles. Some parenchymatic cells became voluminous and devoid of chloroplasts. SEM examination revealed a loss of bilateral symmetry of the stomata and disappearance of the subsidiary cells from the stomata near the midrib at the adaxial surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC). The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics) to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm(3).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The temperature and velocity distributions of the air inside the cabinet of domestic refrigerators affect the quality of food products. If the consumer knows the location of warm and cold zones in the refrigerator, the products can be placed in the right zone. In addition, the knowledge of the thickness of thermal and hydrodynamic boundary layers near the evaporator and the other walls is also important. If the product is too close to the evaporator wall, freezing can occur, and if it is too close to warm walls, the products can be deteriorated. The aim of the present work is to develop a steady state computational fluid dynamics (CFD) model for domestic refrigerators working on natural convection regime. The Finite Volume Methodology is chosen as numerical procedure for discretizing the governing equations. The SIMPLE-Semi-Implicit Method for Pressure-Linked Equations algorithm applied to a staggered mesh was used for solving the pressure-velocity coupling problem. The Power-Law scheme is employed as interpolation function for the convective-diffusive terms, and the TDMA-Tri-Diagonal Matrix Algorithm is used to solve the systems of algebraic equations. The model is applied to a commercial static refrigerator, where the cabinet is considered an empty three-dimensional rectangular cavity with one drawer at the bottom of the cabinet, but without shelves. In order to analyze the velocity and temperature fields of the air flow inside the cabinet the evaporator temperature, Te, was varied from -20 degrees C to 0 degrees C, and nine different evaporator positions are evaluated for evaporator temperature of -15 degrees C. The cooling capacity of the evaporator for the steady state regime is also computed for each case. One can conclude that the vertical positioning of the evaporator inside the cabinet plays an important role on the temperature distribution inside the cabinet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A green ceramic tape micro heat exchanger was developed using LTCC technology. The device was designed by using a CAD software and 2D and 3D simulations using a CFD package (COMSOL Multiphysics) to evaluate the fluid behavior in the microchannels. The micro heat exchanger is composed of five thermal exchange plates in cross flow arrangement and two connecting plates; heat exchanger dimensions are 26 × 26 × 6 mm3. Preliminary tests were carried out to characterize the device both in atmospheric pressure and in vacuum. The same techniques used in vacuum technology were applied to check the rotameters and to prevent device leakages. Thermal performance of the micro heat exchanger was experimentally tested. © 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to develop procedures for assessing reading comprehension of words and phrases and characterize the performance of students of 2nd year of elementary school in this procedure. It was divided into two phases: 1) preparation of evaluation tests of reading comprehension, consisting of three events: comprehension of written word (CWW), sentences (CWS) and sentences through pictures (CSP) and 2) application of the elaborated evaluation in 120 students distributed in the following groups: GI, 60 students from a public (municipal) school and GII, 60 students from a private school. The CWW test obtained the highest average of score, followed by CSP and CWS for both groups, since the picture contributes to the comprehension of the meaning either of the word and sentences. The procedure was effective to assess initial skills of reading comprehension once it identified inherent difficulties related to the literacy process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)