7 resultados para Standarization of the system

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a recent performance work I made using dance and live feed video
processing, 1 + x: mid-range projections, commissioned by the Seoul Contemporary Dance
Company and first performed in Melbourne in July 2005. This work forms a basis for discussing
my interest in creating performance images that reveal 'interiority'. I am interested in how you
embed the 'feel' of the human systematically in an interactive structure, and how that process
can produce a poetic that arises from the detailed and nuanced play between real and virtual
images on the same screen. How do you abstract and play with a performer's movement, play
with it in real and virtual time, so that it gives the work an emotional charge? Its like playing with
the process of 'becoming virtual' - and I'm being deliberately Deleuzian about that - how do you
'become virtual' in the sense of melding performer and image so that the meaning exists
between - in the connection between the two?

This quest to get the energy, the 'lived', 'felt' quality of the movement into the imagery gives rise
to research questions about how 'presence' is perceived in movement. What elements of the
raw movement data do you need to keep and what can you throwaway, and still keep the
personality, the emotion, the 'life' of that movement? How do you make a virtual, interactive
performance system that has its own 'materiality'?

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Children frequently engage in diverse activities that are broadly defined as play, but little research has documented children’s activity levels during play and how they are influenced by social contexts. Assessing potentially modifiable conditions that influence play behavior is needed to design optimal physical activity interventions.

Methods: System for Observing Children’s Activity and Relationships during Play (SOCARP) was developed to simultaneously assess children’s physical activity, social group sizes, activity type, and social behavior during play. One hundred and fourteen children (48 boys, 66 girls; 42% overweight) from 8 elementary schools were observed during recess over 24 days, with 12 days videotaped for reliability purposes. Ninety-nine children wore a uni-axial accelerometer during their observation period.

Results: Estimated energy expenditure rates from SOCARP observations and mean accelerometer counts were significantly correlated (r = .67; P < .01), and interobserver reliabilities (ie, percentage agreement) for activity level (89%), group size (88%), activity type (90%) and interactions (88%) met acceptable criteria. Both physical activity and social interactions were influenced by group size, activity type, and child gender and body weight status.

Conclusions: SOCARP is a valid and reliable observation system for assessing physical activity and play behavior in a recess context.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Deakin Studies Online (DSO) Learning Management System (LMS) forms the fundamental basis for tertiary education at Deakin University. This LMS is founded on Web 1.0 principles, however significant potential exists for engagement in Web 2.0 technologies to support learning and teaching in the design studio. A digitally enhanced design curriculum is discussed starting with html-based reflective folios in 2001, the use of blogs for reflection and resource creation and culminating in a Web 2.0 design studio based on social networking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reaction of tris(2,2’-bipyridyl)ruthenium(III) (Ru(bipy) 33+) with various analytes to generate chemiluminescence has been well documented. This investigation sought to undertake a chemiluminometic study of the reactions of Ru(bipy) 33+ with selected Papaver Somniferum alkaloids and specifically synthesised phenethylamines. The investigation, based on a kinetic study, primarily addressed the effect of varying reaction conditions (pH) on Ru(bipy) 33+ chemiluminescence production. To monitor these reactions, a batch chemiluminometer was specifically designed, fabricated and automated to conduct an extensive study on the selected compounds of interest. The instrumentation incorporated a custom built reaction cell and comprised an ‘on-line’ sample preparation system with which calibration standards could be automatically prepared. The instrumentation provided both time-independent (peak area) and time-dependent (kinetic profile) information. A novel approach to the stabilisation of Ru(bipy) 33+ as a chemiluminescencent reagent was also investigated and a recirculating system was employed with the batch chemiluminometer to provide a stable supply of Ru(bipy) 33+. Codeine, thebaine and 6-methoxy-codeine were the Papaver Somniferum alkaloids selected for this study and several N-methylated and N,N-dimethylated phenethylamines and methoxy-substituted phenetheylamines were also synthesised to investigate the affect of pH on the chemiluminescence emission efficiency. The versatility of the batch chemiluminometer facilitated the kinetic study of numerous analytes over a broad pH range. The exemplary performance of the chemiluminometer as an analytical instrument, was demonstrated by the calibration functions, based on peak area data, which exhibited excellent linearity and sensitivity. The estimated detection limits (3s) for the selected alkaloids were in the range 2 x 10-9 M to 7 x 10-9 at pH 5.0 and above, which compared favourably to detection limits for the same compounds determined using FIA. Relative standard deviations (n=5) for peak areas ranged between 1% to 5% with a mean of 3.1% for all calibration standards above 2.5 x 10-8 M. Correlation between concentration and peak area, irrespective of pH and analyte was excellent, with all but two calibration functions having r-squared values greater than 0.990. The analytical figures of merit exemplified the precision and robustness of the reagent delivery and ‘on-line’ sample preparation, as well as the sensitivity of the system. The employment of the chemiluminometer for the measurement of total chemiluminescence emission (peak area) was in itself a feasible analytical technique, which generated highly reproducible and consistent data. Excellent analytical figures of merit, based on peak area, were similarly achieved for the phenethylamines. The effects of analyte structure on chemiluminescence activity was also investigated for the alkaloids and the phenethylamines. Subtle structural variations between the three alkaloids resulted in either a moderately reduced or enhanced total emission that was two or three fold difference only. A significant difference in reaction kinetics was observed between thebaine and codeine/6-methoxy-codeine, which was dependent upon pH. The time-dependent data, namely the observed rate constants for the initial rise in intensity and for the subsequent decay rate, were obtained by fitting a mathematical function (based on the postulated reaction mechanism) to the raw data. The determination of these rate constants for chemiluminescence reactions highlighted the feasibility for utilising such measurements for quantitative analytical applications. The kinetic data were used to discriminate between analyte responses in order to determine the concentrations of individual analytes in a binary mixture. A preliminary, multi-component investigation performed on a binary mixture of codeine and 6-methoxy-codeine (1:1) successfully determined the concentrations of these individual components using such rate constant measurements. Consequently, variations in kinetics resulted in a significant difference between the relative chemiluminescence response based on peak area measurements and the relative response base on peak height measurements obtained using FIA. With regards to the observed reactivity of secondary amines and tertiary amines, chemiluminescence peak area determinations confirmed the vital role of pH on reaction efficiency, which was governed by structural features and kinetics. The tertiary amines investigated generally produced a greater emission under acidic conditions than the corresponding secondary amines. However, the measured chemiluminescence responses were highly dependent upon pH, with similar peak areas obtained for both amine groups under slightly alkaline conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last 30 to 40 years, many researchers have combined to build the knowledge base of theory and solution techniques that can be applied to the case of differential equations which include the effects of noise. This class of ``noisy'' differential equations is now known as stochastic differential equations (SDEs). Markov diffusion processes are included within the field of SDEs through the drift and diffusion components of the Itô form of an SDE. When these drift and diffusion components are moderately smooth functions, then the processes' transition probability densities satisfy the Fokker-Planck-Kolmogorov (FPK) equation -- an ordinary partial differential equation (PDE). Thus there is a mathematical inter-relationship that allows solutions of SDEs to be determined from the solution of a noise free differential equation which has been extensively studied since the 1920s. The main numerical solution technique employed to solve the FPK equation is the classical Finite Element Method (FEM). The FEM is of particular importance to engineers when used to solve FPK systems that describe noisy oscillators. The FEM is a powerful tool but is limited in that it is cumbersome when applied to multidimensional systems and can lead to large and complex matrix systems with their inherent solution and storage problems. I show in this thesis that the stochastic Taylor series (TS) based time discretisation approach to the solution of SDEs is an efficient and accurate technique that provides transition and steady state solutions to the associated FPK equation. The TS approach to the solution of SDEs has certain advantages over the classical techniques. These advantages include their ability to effectively tackle stiff systems, their simplicity of derivation and their ease of implementation and re-use. Unlike the FEM approach, which is difficult to apply in even only two dimensions, the simplicity of the TS approach is independant of the dimension of the system under investigation. Their main disadvantage, that of requiring a large number of simulations and the associated CPU requirements, is countered by their underlying structure which makes them perfectly suited for use on the now prevalent parallel or distributed processing systems. In summary, l will compare the TS solution of SDEs to the solution of the associated FPK equations using the classical FEM technique. One, two and three dimensional FPK systems that describe noisy oscillators have been chosen for the analysis. As higher dimensional FPK systems are rarely mentioned in the literature, the TS approach will be extended to essentially infinite dimensional systems through the solution of stochastic PDEs. In making these comparisons, the advantages of modern computing tools such as computer algebra systems and simulation software, when used as an adjunct to the solution of SDEs or their associated FPK equations, are demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report results of atomistic molecular dynamics simulations of an industrially-relevant, exemplar triacylglycerol (TAG), namely tristearin (TS), under aqueous conditions, at different temperatures and in the presence of an anionic surfactant, sodium dodecylbenzene sulphonate (SDBS). We predict the TS bilayers to be stable and in a gel phase at temperatures of 350 K and below. At 370 K the lipid bilayer was able to melt, but does not feature a stable liquid-crystalline phase bilayer at this elevated temperature. We also predict the structural characteristics of TS bilayers in the presence of SDBS molecules under aqueous conditions, where surfactant molecules are found to spontaneously insert into the TS bilayers. We model TS bilayers containing different amounts of SDBS, with the presence of SDBS imparting only a moderate effect on the structure of the system. Our study represents the first step in applying atomistic molecular dynamics simulations to the investigation of TAG-aqueous interfaces. Our results suggest that the CHARMM36 force-field appears suitable for the simulation of such systems, although the phase behaviour of the system may be shifted to lower temperatures than is the case for the actual system. Our findings provide a foundation for further simulation studies of the TS-aqueous interface.