88 resultados para dental device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study seeks to develop a comprehensive model of consumer acceptance in the context of Smart Mobile Device (SMDs). This paper proposes an adaptation of the Technology Acceptance Model (TAM) and the Unified Theory of Acceptance and Use of Technology (UTAUT2) model that can be employed to explain and predict the acceptance of SMDs. Also included in the model are a number of external and new moderating variables that can be used to explain user intentions and subsequent usage behaviour. The model holds that Activity-based Usage and Device Characteristics are posited to moderate the impact of the constructs empirically validated in the UTAUT2 model. Through an important cluster of antecedents the proposed model aims to enhance our understanding of consumer motivations for using SMDs and aid efforts to promote the adoption and diffusion of these devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existing haptic and non-haptic dental simulators do not eliminate the problem of hand instability while using the haptic devices for training purpose. This paper reports an audio-haptic dental training platform, which uses a Hand Stability System to reduce the effect of nervousness and hand instability for trainee dental students. Maintaining the ease of implementation, application customizability and the cost factor, the proposed platform increases the training efficiency by enhancing the immersive haptic experience with hand stability. This haptic platform includes multiple angle viewing techniques, audio feedback and session recording for after action review. Trials using this preliminary platform reduced the effect of human nervousness and hand instability due to the customized design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This OXADM are located in the nodes, which have more than two switching directions in ring networks. The function of OXADM is to flexibility switch the wavelengths among the different input and output ports. Because of the OXADM's imperfect performance, the insertion loss and crosstalk are induced in the system. Analytical modeling method is using to analyze the OXADM structure in crosstalk or power leakage that lead to the power penalty. To overcome this problem, power penalty is needed to be supplied. The insertion of this power penalty depends on few parameters. The parameters that we going to investigate here will be in term of number of operating wavelengths and number of input/output ports as well as the Q factor. The variation of this parameters will affects the amount of the desired power penalty. Simulation results in higher crosstalk or higher power penalty needed as the number of OXADM increases. As the sum of the wavelength and the number of input/output for each OXADM increases, the power penalty will increased as well. Investigation on the maximum Q factors is 6 to get the minimum power penalty at the lowest BER for most of the combination of the sum of the wavelength and the number of input/output for each OXADM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple sample DNA amplification was done by using a novel rotary-linear motion polymerase chain reaction (PCR) device. A simple compact disc was used to create the stationary sample chambers which are individually temperature controlled. The PCR was performed by shuttling the samples to different temperature zones by using a combined rotary-linear movement of the disc. The device was successfully used to amplify up to 12 samples in less than 30 min with a sample volume of 5 μl. A simple spring loaded heater mechanism was introduced to enable good thermal contact between the samples and the heaters. Each of the heater temperatures are controlled by using a simple proportional–integral–derivative pulse width modulation control system. The results show a good improvement in the amplification rate and duration of the samples. The reagent volume used was reduced to nearly 25% of that used in conventional method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective
The authors undertook an updated systematic review of the relationship between body mass index and dental caries in children and adolescents.
Method
The authors searched Medline, ISI, Cochrane, Scopus, Global Health and CINAHL databases and conducted lateral searches from reference lists for papers published from 2004 to 2011, inclusive. All empirical papers that tested associations between body mass index and dental caries in child and adolescent populations (aged 0 to 18 years) were included.
Results
Dental caries is associated with both high and low body mass index.
Conclusion
A non-linear association between body mass index and dental caries may account for inconsistent findings in previous research. We recommend future research investigate the nature of the association between body mass index and dental caries in samples that include a full range of body mass index scores, and explore how factors such as socioeconomic status mediate the association between body mass index and dental caries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is now time for teachers as well as colleges to make a place for mobile learning within the classroom setting. Teachers should be encouraged to integrate mobile phones for teaching and learning within the classroom, as they can be seen as an effective learning tool for students of all ages. We believe that mobile phone bans in colleges should be reviewed and reconsidered. This paper draws on some important aspects which mobile phones can bring into the classroom; it illustrates how mobile phones can fit seamlessly in a normal classroom environment; and the advantages that they provide. A possible integration method which encourages collaboration among students and teacher will be discussed and proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A circular planar inverted-F antenna (PIFA) is designed and simulated at the industrial, scientific, and medical (ISM) band of 915 MHz for energy harvesting in a head-mountable deep brain stimulation device. Moreover, a rectifier is designed, and also the interaction of the PIFA with a rat head model is investigated. In the proposed PIFA, the top radiating layer is meandered, and a substrate of FR-4 is used. The radius and the height of the antenna are 10 mm and 1.8 mm, respectively. The bottom conductive layer works as a ground plate, and a superstrate of polyethylene reduces the electromagnetic penetration into the rat head. The resonance frequency of the designed antenna is 915 MHz with a bandwidth of 18 MHz at the return loss of -10 dB in free space. The antenna parameters (e.g. reflection coefficient, gain, radiation efficiency), electric field distribution, and SAR value are evaluated within a seven-layer rat head model by using the finite difference time domain EM simulation software XFdtd. The interactions of the antenna and the rat head model are studied in both functional and biological aspects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an Electrowetting-on-Dielectric (EWOD) device with optimized insulating layers operated by low actuation voltage. The device consists of an electrode array on a silicon substrate, covered by a dielectric layer and a hydrophobic layer. To characterize the performance of the device, simulations are performed for the dielectric layer of Sio2 and the hydrophobic layer of Sio2, Su-8 and Parylene C at different voltages. The volume finite difference approach of the Coventorware software was used to carry out the simulations. Two different molar of di-ionized water droplet were considered in the simulations. It was observed that the device having the Sio2 dielectric layer and the Parylene C hydrophobic layer moved the 1M KCL (potassium chloride) droplet at the actuation voltage of 25V.