163 resultados para Chemiluminescence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adrenergic amines found in extracts of Citrus aurantium (bitter orange) evoke analytically useful chemiluminescence with acidic potassium permanganate in the presence of polyphosphates. From corrected chemiluminescence spectra, the wavelength of maximum intensity for these reactions was 680 ± 5 nm and, using flow injection analysis methodology, limits of detection for synephrine, octopamine, tyramine and hordenine were found to be between 1 × 10−9 and 1 × 10−8 M. We have applied this method of detection to the rapid determination of synephrine in dietary supplements using monolithic column chromatography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mixtures of silver(I) and citrate that are used to produce silver nanoparticles evoke intense chemiluminescence with tris(2,2'-bipyridyl)ruthenium(II) and cerium(IV), which can be exploited for the determination of citrate ions and other analytes over a wide concentration range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An investigation into the chemiluminescence of fourteen organic acids and tris(2,2′-bipyridyl)ruthenium(II) was undertaken. Particular emphasis was placed upon the method of production of the reagent, tris(2,2′-bipyridyl)ruthenium(III), with cerium(IV) sulfate, potassium permanganate, lead dioxide and electrochemical generation. Analytically useful chemiluminescence was observed when Ce(IV) or potassium permanganate were employed as oxidants. The kinetics of analyte oxidation was related to the intensity of the chemiluminescence emission, which increased by three orders of magnitude for tartaric acid after 40 h of oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel chemiluminescence flow injection procedure for the determination of As(III) in aqueous samples is described. The method involves injection of As(III) samples into a 1% (m/v) sodium hexametaphosphate in 0.02 M H2SO4 carrier stream, which then merges at a Y-piece with a reagent stream consisting of potassium permanganate (5.0 × 10−5 M) made up in the acidic sodium hexametaphosphate carrier solution. The chemiluminescence intensity of the resulting reaction mixture was measured at a photomultiplier tube operated at a voltage of 0.93 kV. Under optimized conditions, the method is characterised by a linear range from 0.5 to 5.0 μg l−1, a detection limit of 0.3 μg l−1 and a sampling frequency of 150 h−1. The effects of common anionic and cationic interferences were investigated, and it was found that the only ions to cause serious interference were those which react with potassium permanganate, namely sulphide, iodide and ferrous.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article Outline
• Introduction
Chemiluminescence of Nitrogen Compounds
• Thermal Energy Analyzer
• Nitrogen-Selective Detector
• Redox Chemiluminescence Detection
Chemiluminescence of Sulfur Compounds
Chemiluminescence of Hydrocarbons
• Other Reactions with Ozone
• Flame Photometric Detector
• Other Reagent Gases
• Molecular Fluorine
• Atomic Fluorine
• Atomic Oxygen
• Active Nitrogen
• Atomic Sodium
• Chlorine Dioxide
• Official Methods
• Further Reading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article Outline
• Introduction
• Acidic Potassium Permanganate
• Acridinium Esters
• Diaryl Oxalates and Oxamides
• Dioxetanes
• Hypohalites
• Luminol and Its Analogs
• Tris(2,2′-bipyridyl)ruthenium(II)
• Practical Considerations
• HPLC and Flow Analysis
• Capillary Electrophoresis
• Enzyme Reaction Products
• Immunoassay and DNA Assays
• Further Reading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article Outline
• Introduction
• Principles
• Reaction Kinetics and the Observed Signal
Chemiluminescence versus Fluorescence Detection
• Selectivity
• Corrected Emission Spectra
• Gas-Phase Reactions
• Liquid-Phase Reactions
• Solid-Phase Reactions
• Acknowledgements
• Further Reading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Further consideration has been given to the reaction pathway of a model peroxyoxalate chemiluminescence system. Again utilising doubly labelled oxalyl chloride and anhydrous hydrogen peroxide, 2D EXSY 13C nuclear magnetic resonance (NMR) spectroscopy experiments allowed for the characterisation of unknown products and key intermediate species on the dark side of the peroxyoxalate chemiluminescence reaction. Exchange spectroscopy afforded elucidation of a scheme comprised of two distinct mechanistic pathways, one of which contributes to chemiluminescence. 13C NMR experiments carried out at varied reagent molar ratios demonstrated that excess amounts of hydrogen peroxide favoured formation of 1,2-dioxetanedione: the intermediate that, upon thermolysis, has been long thought to interact with a fluorophore to produce light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct comparison of the laser-induced photoluminescence of manganese(II) with the chemiluminescence from the reaction between acidic potassium permanganate and sodium borohydride was used to confirm that the characteristic red emission from this widely used chemiluminescence reagent emanates from an electronically excited manganese(II) species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sequential injection analysis procedure with dual-reagent chemiluminescence detection was applied to the screening of street drug seizure samples for the presence of heroin. The chemiluminescence reagents (acidic potassium permanganate and tris(2,2′-bipyridine)ruthenium(III)) were aspirated from either side of a sample aliquot that was sufficiently large to prevent interdispersion of the reagent zones, and therefore two different chemical reactions could be performed simultaneously at either end of the sample zone. The presence of heroin in seizure samples was indicated by a strong response with the tris(2,2′-bipyridine)ruthenium(III) reagent and confirmed by a significant increase in the response with the permanganate reagent when the sample was treated with sodium hydroxide to hydrolyse the heroin to morphine. Nicomorphine (a morphine-derived pharmaceutical) was synthesised and tested under the same conditions. The responses with the permanganate reagent were similar to those for heroin, which supports the proposed chemical basis for the test. However, the responses with tris(2,2′-bipyridine)ruthenium(III) were far lower for nicomorphine than heroin (approximately 5-fold for the samples that had not been hydrolysed).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review with 98 references. The determination of the opium poppy (Papaver somniferum) alkaloids and their semi-synthetic derivatives has important applications in industrial process monitoring, clinical analysis and forensic science. Liquid-phase chemiluminescence reagents such as tris(2,2′-bipyridyl)ruthenium(II) and acidic potassium permanganate exhibit remarkable sensitivity and complementary selectivity for many P. somniferum alkaloids, which has been exploited in the development of a range of analytical procedures using flow analysis, high-performance liquid chromatography, capillary electrophoresis and microfluidic instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although potassium permanganate [Mn(VII)] has been used extensively as a chemiluminescence reagent for many decades, other manganese-based oxidants have only recently been explored for this purpose. There is strong evidence to suggest that, like permanganate, manganese(III) and manganese(IV) oxidants react with many molecules to produce an excited manganese(II) species that emits light. However, these reagents differ markedly in terms of selectivity, and possess characteristics that provide new avenues for detection, such as the immobilisation of solid manganese dioxide, the production of ‘soluble’ manganese(IV) nanoparticles, and the electrochemical generation of manganese(III). In this review we examine the emergence of these alternative manganese oxidants as chemiluminescence reagents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new chemiluminescence detector, with solution channels that have been machined into a Teflon disk and sealed with a sapphire window. The configuration of the flow cell can be conveniently modified by replacing the Teflon disk. A comparison of some existing and novel designs, using the chemiluminescence reaction of morphine with acidic potassium permanganate and the bioluminescence reaction of ATP with the commercially available “BacTiter-Glo” reagent, has revealed that a serpentine channel allows greater quantities of light to be captured than a spiral channel, due to more efficient mixing of the analyte and reagent solutions within the cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have suggested that tris(4,7-diphenyl-1,10-phenanthrolinedisulfonate)ruthenium(II) (Ru(BPS)34−) has great potential as a chemiluminescence reagent in acidic aqueous solution. We have evaluated four different samples of this reagent (two commercially available and two synthesised in our laboratory) in comparison with tris(2,2′-bipyridine)ruthenium(II) (Ru(bipy)32+) and tris(1,10-phenanthroline)ruthenium(II) (Ru(phen)32+), using a range of structurally diverse analytes. In general, Ru(BPS)34− produced more intense chemiluminescence, but the oxidised Ru(BPS)33− species is less stable in aqueous solution than Ru(bipy)33+ and produced a greater blank signal than Ru(bipy)33+ or Ru(phen)33+, which had a detrimental effect on sensitivity. Although the complex is often depicted with the sulfonate groups of the BPS ligand in the para position on the phenyl rings, NMR characterisation revealed that the commercially available BPS material used in this study was predominantly the meta isomer.