40 resultados para high-performance liquid chromatographic methods

em CentAUR: Central Archive University of Reading - UK


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbarnyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 mu m ODS (C-18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min(-1) and the column temperature was maintained at 30 degrees C Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32 +/- 1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15 +/- 0.1 cm(2). The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1 % v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 mu g ml(-1). The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) < 12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <=-5.60 and <=-8.00, respectively. Using this assay, it was found that GL-HCI permeates through human skin with a flux 1.497 +/- 0.42 mu g cm(-2) h(-1), a permeability coefficient of 5.66 +/- 1.6 x 10(-6) cm h(-1) and with a lag time of 10.9 +/- 4.6 h. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: Quinolone antibiotics are the agents of choice for treating systemic Salmonella infections. Resistance to quinolones is usually mediated by mutations in the DNA gyrase gene gyrA. Here we report the evaluation of standard HPLC equipment for the detection of mutations (single nucleotide polymorphisms; SNPs) in gyrA, gyrB, parC and parE by denaturing high performance liquid chromatography (DHPLC). Methods: A panel of Salmonella strains was assembled which comprised those with known different mutations in gyrA (n = 8) and fluoroquinolone-susceptible and -resistant strains (n = 50) that had not been tested for mutations in gyrA. Additionally, antibiotic-susceptible strains of serotypes other than Salmonella enterica serovar Typhimurium strains were examined for serotype-specific mutations in gyrB (n = 4), parC (n = 6) and parE (n = 1). Wild-type (WT) control DNA was prepared from Salmonella Typhimurium NCTC 74. The DNA of respective strains was amplified by PCR using Optimase (R) proofreading DNA polymerase. Duplex DNA samples were analysed using an Agilent A1100 HPLC system with a Varian Helix (TM) DNA column. Sequencing was used to validate mutations detected by DHPLC in the strains with unknown mutations. Results: Using this HPLC system, mutations in gyrA, gyrB, parC and parE were readily detected by comparison with control chromatograms. Sequencing confirmed the gyrA predicted mutations as detected by DHPLC in the unknown strains and also confirmed serotype-associated sequence changes in non-Typhimurium serotypes. Conclusions: The results demonstrated that a non-specialist standard HPLC machine fitted with a generally available column can be used to detect SNPs in gyrA, gyrB, parC and parE genes by DHPLC. Wider applications should be possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Examination by high temperature GC (HTGC) of the methyl esters of the so-called 'ARN' naphthenic acids from crude oils of North Sea UK, Norwegian Sea and West African oilfields revealed the distributions of resolved 4-8 ring C-80 tetra acids and trace amounts of other acids. Whilst all three oils contained apparently the same the proportions of each differed, possibly reflecting the growth tempe acids, ratures of the archaebacteria from which the acids are assumed to have originated. The structures of the 4, 5, 7 and 8 ring acids are tentatively assigned by comparison with the known 6 ring acid and related natural products and an HPLC method for the isolation of the individual acids is described. ESI-MS of individual acids isolated by preparative HPLC established the elution order of the 4-8 ring acids on the HPLC and HTGC systems and revealed the presence of previously unreported acids tentatively identified as C-81 and C-82 7 and 8 ring analogues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymer-stabilised liquid crystals are systems in which a small amount of monomer is dissolved within a liquid crystalline host, and then polymerised in situ to produce a network. The progress of the polymerisation, performed within electro-optic cells, was studied by establishing an analytical method novel to these systems. Samples were prepared by photopolymerisation of the monomer under well-defined reaction conditions; subsequent immersion in acetone caused the host and any unreacted monomer to dissolve. High performance liquid chromatography was used to separate and detect the various solutes in the resulting solutions, enabling the amount of unreacted monomer for a given set of conditions to be quantified. Longer irradiations cause a decrease in the proportion of unreacted monomer since more network is formed, while a more uniform LC director alignment (achieved by decreasing the sample thickness) or a higher level of order (achieved by decreasing the polymerisation temperature) promotes faster reactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Denaturing high-performance liquid chromatography (DHPLC) was evaluated as a rapid screening and identification method for DNA sequence variation detection in the quinolone resistance-determining region of gyrA from Salmonella serovars. A total of 203 isolates of Salmonella were screened using this method. DHPLC analysis of 14 isolates representing each type of novel or multiple mutations and the wild type were compared with LightCycler-based PCR-gyrA hybridization mutation assay (GAMA) and single-strand conformational polymorphism (SSCP) analyses. The 14 isolates gave seven different SSCP patterns, and LightCycler detected four different mutations. DHPLC detected 11 DNA sequence variants at eight different codons, including those detected by LightCycler or SSCP. One of these mutations was silent. Five isolates contained multiple mutations, and four of these could be distinguished from the composite sequence variants by their DHPLC profile. Seven novel mutations were identified at five different loci not previously described in quinolone-resistant salmonella. DHPLC analysis proved advantageous for the detection of novel and multiple mutations. DHPLC also provides a rapid, high-throughput alternative to LightCycler and SSCP for screening frequently occurring mutations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) offers the analyst a number of key advantages for the analysis of the components of foods. CE offers better resolution than, say, high-performance liquid chromatography (HPLC), and is more adept at the simultaneous separation of a number of components of different chemistries within a single matrix. In addition, CE requires less rigorous sample cleanup procedures than HPLC, while offering the same degree of automation. However, despite these advantages, CE remains under-utilized by food analysts. Therefore, this review consolidates and discusses the currently reported applications of CE that are relevant to the analysis of foods. Some discussion is also devoted to the development of these reported methods and to the advantages/disadvantages compared with the more usual methods for each particular analysis. It is the aim of this review to give practicing food analysts an overview of the current scope of CE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The High Resolution Dynamics Limb Sounder is described, with particular reference to the atmospheric measurements to be made and the rationale behind the measurement strategy. The demands this strategy places on the filters to be used in the instrument and the designs to which this leads to are described. A second set of filters at an intermediate image plane to reduce "Ghost Imaging" is discussed together with their required spectral properties. A method of combining the spectral characteristics of the primary and secondary filters in each channel are combined together with the spectral response of the detectors and other optical elements to obtain the system spectral response weighted appropriately for the Planck function and atmospheric limb absorption. This method is used to demonstrate whether the out-of-band spectral blocking requirement for a channel is being met and an example calculation is demonstrated showing how the blocking is built up for a representative channel. Finally, the techniques used to produce filters of the necessary sub-millimetre sizes together with the testing methods and procedures used to assess the environmental durability and establish space flight quality are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was undertaken to explore gel permeation chromatography (GPC) for estimating molecular weights of proanthocyanidin fractions isolated from sainfoin (Onobrychis viciifolia). The results were compared with data obtained by thiolytic degradation of the same fractions. Polystyrene, polyethylene glycol and polymethyl methacrylate standards were not suitable for estimating the molecular weights of underivatized proanthocyanidins. Therefore, a novel HPLC-GPC method was developed based on two serially connected PolarGel-L columns using DMF that contained 5% water, 1% acetic acid and 0.15 M LiBr at 0.7 ml/min and 50 degrees C. This yielded a single calibration curve for galloyl glucoses (trigalloyl glucose, pentagalloyl glucose), ellagitannins (pedunculagin, vescalagin, punicalagin, oenothein B, gemin A), proanthocyanidins (procyanidin B2, cinnamtannin B1), and several other polyphenols (catechin, epicatechin gallate, epicallocatechin gallate, amentoflavone). These GPC predicted molecular weights represented a considerable advance over previously reported HPLC-GPC methods for underivatized proanthocyanidins. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Crystallization must occur in honey in order to produce set or creamed honey; however, the process must occur in a controlled manner in order to obtain an acceptable product. As a consequence, reliable methods are needed to measure the crystal content of honey (φ expressed as kg crystal per kg honey), which can also be implemented with relative ease in industrial production facilities. Unfortunately, suitable methods do not currently exist. This article reports on the development of 2 independent offline methods to measure the crystal content in honey based on differential scanning calorimetry and high-performance liquid chromatography. The 2 methods gave highly consistent results on the basis of paired t-test involving 143 experimental points (P > 0.05, r**2 = 0.99). The crystal content also correlated with the relative viscosity, defined as the ratio of the viscosity of crystal containing honey to that of the same honey when all crystals are dissolved, giving the following correlation: μr = 1 + 1398.8∅**2.318. This correlation can be used to estimate the crystal content of honey in industrial production facilities. The crystal growth rate at a temperature of 14 ◦C—the normal crystallization temperature used in practice—was linear, and the growth rate also increased with the total glucose content in the honey.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The feasibility to synthesize, in large quantity, pure and non-toxic tetrahedrite compounds using high-energy mechanical-alloying from only elemental precursors is reported in the present paper for the first time. Our processing technique allows a better control of the final product composition and leads to high thermoelectric performances (ZT of 0.75 at 700 K), comparable to that reported on sealed tube synthesis samples. Combined with spark plasma sintering, the production of highly pure and dense samples is achieved in a very short time, at least 8 times shorter than in conventional liquid-solid-vapor synthesis process. The process described in this paper is a promising way to produce high performance tetrahedrite materials for cost-effective and large-scale thermoelectric applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sources of ordinate error in FTIR spectrometers are reviewed with reference to measuring small out-of-band features in the spectra of bandpass filters. Procedures for identifying instrumental artefacts are described. It is shown that features well below 0.01%T can be measured reliably.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A set of filters based on the sequence of semiconductor edges is described which offers continuity of short-wave infrared blocking. The rejection throughout the stop region is greater than 103 for each filter and the transmission better than 70% through one octave with a square cutoff. The cutoff points are located at intervals of about two-thirds of an octave. Filters at 2.6 ,µm, 5.5 µm, and 12 µm which use a low-passing multilayer in combination with a semiconductor absorption edge are described in detail. The design of multilayers for optimum performance is discussed by analogy with the synthesis of electric circuit filters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study objectives: There is a possibility that lower air, moisture and light protection could impact on physico-chemical stability of medicines inside multi-compartment compliance aids (MCCAs), although this has not yet been proved. The objectives of the study were to examine the physico-chemical stability of atenolol tablets stored in a compliance aid at room temperature, and at elevated temperature and humidity to simulate practice conditions. Methods: Atenolol 100 mg tablets in 28-chamber, plastic compliance aids with transparent lids were stored for four weeks at room temperature and at 40°C with 75% relative humidity. Tablets were also stored at room temperature in original packaging and Petri dishes. Physical tests were conducted to standards as laid down in the British Pharmacopoeia 2005, and dissolution to those of the United States Pharmacopoeia volume 24. Chemical stability was assessed by a validated high-performance liquid chromatography (HPLC) method. Results: Tablets at room temperature in original packaging, in compliance aids and Petri dishes remained the same in appearance and passed physico-chemical tests. Tablets exposed to 40°C with 75% relative humidity in compliance aids passed tests for uniformity of weight, friability and chemical stability but became pale and moist, softer (82 newtons ± 4; p< 0.0001) than tablets in the original packaging (118 newtons ± 6), more friable (0.14% loss of mass) compared with other tablets (0.005%), and failed the tests for disintegration (>15 minutes) and dissolution (only 15% atenolol released at 30 minutes). Conclusion: Although chemical stability was unaffected, storage in compliance aids at 40°C with 75% relative humidity softened atenolol tablets, prolonged disintegration time and hindered dissolution which could significantly reduce bioavailability. This formulation could be suitable for storage in compliance aids at 25°C, but not in hotter, humid weather.