6 resultados para urine

em Cochin University of Science


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current study is an attempt to find a means of lowering oxalate concentration in individuals susceptible to recurrent calcium oxalate stone disease.The formation of renal stone composed of calcium oxalate is a complex process that remains poorly understood and treatment of idiopathic recurrent stone formers is quite difficult and this area has attracted lots of research workers. The main objective of this work are to study the effect of certain mono and dicarboxylic acids on calcium oxalate crystal growth in vitro, isolation and characterization of oxalate degrading bacteria, study the biochemical effect of sodium glycollate and dicarboxylic acids on oxalate metabolism in experimental stone forming rats and To investigate the effect of dicarboxylic acids on oxalate metabolism in experimental hyperoxaluric rats. Oxalic acid is one of the most highly oxidized organic compound widely distributed in the diets of man and animals, and ingestion of plants that contain high concentration of oxalate may lead to intoxication. Excessive ingestion of dietary oxalate may lead to hyperoxaluria and calcium oxalate stone disease.The formation of calcium oxalate stone in the urine is dependent on the saturation level of both calcium and oxalate. Thus the management of one or both of these ions in individuals susceptible to urolithiasis appears to be important. The control of endogenous oxalate synthesis from its precursors in hyperoxaluric situation is likely to yield beneficial results and can be a useful approach in the medical management of urinary stones. A variety of compounds have been investigated to curtain endogenous oxalate synthesis which is a crucial factor, most of these compounds have not proved to be effective in the in vivo situation and some of them are not free from the toxic effect. The non-operative management of stone disease has been practiced in ancient India in the three famous indigenous systems of medicine, Ayurveda, Unani and Siddha, and proved to be effective.However the efficiency of most of these substances is still questionable and demands further study. Man as well as other mammals cannot metabolize oxalic acid. Excessive ingestion of oxalic acid can arise from oxalate rich food and from its major metabolic precursors, glycollate, glyoxylate and ascorbic acid can lead to an acute oxalate toxicity. Increasedlevels of circulating oxalate, which can result in a variety of diseases including renal failure and oxalate lithiasis. The ability to enzymatically degrade oxalate to less noxious Isubstances, formate and CO2, could benefit a great number of individuals including those afflicted with hyperoxaluria and calcium oxalate stone disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A metalloporphyrin incorporated carbon paste sensor has been developed for the determination of metronidazole benzoate (MTZB). Zn(II) complex of 5,10,15,20-tetrakis (3-methoxy-4-hydroxy phenyl) porphyrin (TMHPP) was used as the active material. The MTZB gave a well-defined reduction peak at - 0.713V in 0.1 mol l -1 phosphate buffer solution of pH around 7. Compared with bare carbon paste electrode (CPE), the TMHPP Zn(II) modified electrode significantly enhanced the reduction peak current of MTZB as well as lowered its reduction potential. Under optimum conditions the reduction peak current was proportional to MTZB concentration over the range 1×10-3 mol1-1 to 1×10-5mol1-1. The detection limit was found to be 4.36×10-6mol1-1 . This sensor has been successfully applied for the determination of MTZB in pharmaceutical formulations and urine samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quality of a drug is determined after establishing its authenticity by testing its purity and quality of the pure substance in the drug and its formulations.Ion selective sensors have become one of the most effective and powerful means for analytical scientists in the determination of drug substances and are playing an increasing role in pharmaceutical analysis.ISEs are cost effective,easy to prepare and can be rapidly manipulated . Potentiometric ion selective sensors have been developed for six drugs namely trimethoprim, ketoconazole, lamivudine, domperidon, nimesulide and Lomefloxacin. The sensors fabricated include both PVC membrane sensor as well as carbon paste sensor. A total of sixteen different sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied to the determination of the drugs in pharmaceutical formulations and also in real samples like urine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Potentiometric chemical sensors,an important class of electro-chemical sensors are widely used in pharmaceutical analysis because of its inherent advantages.The present study was aimed at fabrication of potentiometric sensors for the drugs mebendazole,pefloxacin,ambroxol,sildenafil citrate,dextro-methorphan and tetracycline.A total of 18 sensors have been developed for the determination of theses drugs.The major step in the fabrication of the sensor was the preparation of the ion association.Two types of sensors viz:PVC membrane sensor and carbon paste electode (CPE) were fabricated.The response characteristics of the different sensors fabricated were studied.Various response parameters studied include response time,selectivity and the effect of pH.The developed sensors were also employed for the determination of the drugs in pharmaceutical formulations and also for the recovery of the drug from urine samples.The selectivity studies reveal that the developed sensors are highly selective to the drug even in prescence of foreign ions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fabrication and electrochemical response characteristics of two novel potentiometric sensors for the selective determination of domperidone (DOM) are described. The two fabricated sensors incorporate DOM–PTA (phosphotungstic acid) ion pair as the electroactive material. The sensors include a PVC membrane sensor and a carbon paste sensor. The sensors showed a linear, stable, and near Nernstian slope of 56.5 and 57.8 mV/decade for PVC membrane and carbon paste sensors, respectively over a relatively wide range of DOM concentration (1.0 9 10-1–1.0 9 10-5 and 1.0 9 10-1–3.55 9 10-6 M). The response time of DOM–PTA membrane sensor was less than 25 s and that in the case of carbon paste sensor was less than 20 s.Auseful pH range of 4–6 was obtained for both types of sensors. A detection limit of 7.36 9 10-5 M was obtained for PVC membrane sensor and 1.0 9 10-6 M was obtained for carbon paste sensor. The proposed sensors showed very good selectivity toDOMin the presence of a large number of other interfering ions. The analytical application of the developed sensors in the determination of the drug in pharmaceutical formulations such as tablets was investigated. The results obtained are in good agreement with the values obtained by the standard method. The sensors were also applied for the determination ofDOMin real samples such as urine by the standard addition method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A differential pulse voltammetric sensor for the determination of tamsulosin hydrochloride (TAM) using multiwalled carbon nanotubes (MWNTs)–Nafion-modified glassy carbon electrode (GCE) has been developed. MWNTs were dispersed in water with the help of Nafion and were used to modify the surface of GCE via solvent evaporation. At MWNT-modified electrode, TAM gave a well-defined oxidation peak at a potential of 1084 mV in 0.1 M acetate buffer solution of pH 5. Compared to the bare electrode, the peak current of TAM showed a marked increase and the peak potential showed a negative deviation. The determination conditions, such as the amount of MWNT–Nafion suspension, pH of the supporting electrolyte and scan rate, were optimised. Under optimum conditions, the oxidation peak current was proportional to the concentration of TAM in the range 1 × 1023 M–3 × 1027 M with a detection limit of 9.8 × 1028 M. The developed sensor showed good stability, selectivity and was successfully used for the determination of TAM in pharmaceutical formulations and urine samples