3 resultados para process measurement

em Brock University, Canada


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess the effects of changing a nursing documentation system, developed from King's Conceptual Framework, on the use of the nursing process. The null hypothesis was that there would be no significant increase in the reflection of the use of the nursing process on the nursing care plan or nurses' notes, as a result of using a nursing documentation system developed using King's Conceptual Framework (1981). The design involved the development of a questionnaire that was used to review health records pre and post implementation of a documentation system developed based on King's Conceptual Framework and Theory of Goal Attainment (1981). A Record Completeness Score was obtained from some of the questions. The null hypothesis was rejected. The results of the study have implications for nursing administration and the evaluation of nursing practice. If the use of a documentation system developed from a conceptual framework increases the reflection of the nursing process on the patient's health record, nursing will have the means to measure patient outcomes/goal attainment. All health care organizations and levels of government are focusing on methods to monitor and control the health-care dollar. In order for nursing to clearly determine the costs associated with nursing care, measurement of patient outcomes/goal attainment will need to be possible. In order to measure patient outcomes/goals attainment nurses will need to be able to collect data on their practice. It will be critical that nursing have a documentation system in place which facilitates the reflection of the nursing process within a theoretical framework.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whiplash injuries are common yet enigmatic to substantiate clinically. Trigeminal somatosensory evoked potentials (TSEPs) were posited as an indicator of trigeminal nerve conduction damage resulting from whiplash. Alternating polarity square-wave current stimuli were applied transcutaneously in the facial region. 379 recorded pilot trials from 27 participants (8 male and 19 female) were utilized to develop a non-invasive recording capability for TSEPs. Stimulus intensity and artifact, cortical recording sites, stimulation electrode design and placement were explored. Statistically significant differences in amplitude of TSEP waveform components at 13, 19 and 27 ms between uninjured and whiplashed participants were noted. Increased stimulus intensity in whiplashed participants was observed to increase TSEP amplitude. The present methodology and hardware are discussed and directions for future advancement of the current process are outlined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study has two main objectives. First, the phlebotomy process at the St. Catharines Site of the Niagara Health System is investigated, which starts when an order for a blood test is placed, and ends when the specimen arrives at the lab. The performance measurement is the flow time of the process, which reflects concerns and interests of both the hospital and the patients. Three popular operational methodologies are applied to reduce the flow time and improve the process: DMAIC from Six Sigma, lean principles and simulation modeling. Potential suggestions are provided for the St. Catharines Site, which could result in an average of seven minutes reduction in the flow time. The second objective addresses the fact that these three methodologies have not been combined before in a process improvement effort. A structured framework combining them is developed to benefit future study of phlebotomy and other hospital processes.