2 resultados para metered dose inhaler, nebulizer

em Brock University, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent dose-response sleep restriction studies, in which nightly sleep is curtailed to varying degrees (e.g., 3-, 5-, 7-hours), have found cumulative, dose-dependent changes in sleepiness, mood, and reaction time. However, brain activity has typically not been measured, and attentionbased tests employed tend to be simple (e.g., reaction time). One task addressing the behavioural and electrophysiological aspects of a specific attention mechanism is the Attentional Blink (AB), which shows that the report accuracy of a second target (T2) is impaired when it is presented soon after a first target (Tl). The aim of the present study was to examine behavioural and electrophysioiogical responses to the AB task to elucidate how sleep restriction impacts attentional capacity. Thirty-six young-adults spent four consecutive days and nights in a sleep laboratory where sleep, food, and activity were controlled. Nightly sleep began with a baseline sleep (8 hours), followed by two nights of sleep restriction (3,5 or 8 hours of sleep), and a recovery sleep (8 hours). An AB task was administered each day at 11 am. Results from a basic battery oftests (e.g., sleepiness, mood, reaction time) confirmed the effectiveness of the sleep restriction manipulation. In terms of the AB, baseline performance was typical (Le., T2 accuracy impaired when presented soon after Tl); however, no changes in any AB behavioural measures were observed following sleep restriction for the 3- or 5-hour groups. The only statistically significant electrophysiological result was a decrease in P300 amplitude (for Tl) from baseline to the second sleep restriction night for the 3-hour group. Therefore, following a brief, two night sleep restriction paradigm, brain functioning was impaired for the TI of the AB in the absence of behavioural deficit. Study limitations and future directions are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.