9 resultados para analytical method validation

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The nitration of tyrosine residues in proteins is associated with nitrosative stress, resulting in the formation of 3-nitrotyrosine (3-NT). 3-NT levels in biological samples have been associated with numerous physiological and pathological conditions. For this reason, several attempts have been made in order to develop methods that accurately quantify 3-NT in biological samples. Regarding chromatographic methods, they seem to be very accurate, showing very good sensibility and specificity. However, accurate quantification of this molecule, which is present at very low concentrations both at physiological and pathological states, is always a complex task and a target of intense research. Objectives: We aimed to develop a simple, rapid, low-cost and sensitive 3-NT quantification method for use in medical laboratories as an additional tool for diagnosis and/or treatment monitoring of a wide range of pathologies. We also aimed to evaluate the performance of the HPLC-based method developed here in a wide range of biological matrices. Material and methods: All experiments were performed on a Hitachi LaChrom Elite® HPLC system and separation was carried out using a Lichrocart® 250-4 Lichrospher 100 RP-18 (5μm) column. The method was further validated according to ICH guidelines. The biological matrices tested were serum, whole blood, urine, B16 F-10 melanoma cell line, growth medium conditioned with the same cell line, bacterial and yeast suspensions. Results: From all the protocols tested, the best results were obtained using 0.5% CH3COOH:MeOH:H2O (15:15:70) as the mobile phase, with detection at wavelengths 215, 276 and 356 nm, at 25ºC, and using a flow rate of 1 mL/min. By using this protocol, it was possible to obtain a linear calibration curve (correlation coefficient = 1), limits of detection and quantification in the order of ng/mL, and a short analysis time (<15 minutes per sample). Additionally, the developed protocol allowed the successful detection and quantification of 3-NT in all biological matrices tested, with detection at 356 nm. Conclusion: The method described in this study, which was successfully developed and validated for 3-NT quantification, is simple, cheap and fast, rendering it suitable for analysis in a wide range of biological matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An analytical method using microwave-assisted extraction (MAE) and liquid chromatography (LC) with fluorescence detection (FD) for the determination of ochratoxin A (OTA) in bread samples is described. A 24 orthogonal composite design coupled with response surface methodology was used to study the influence of MAE parameters (extraction time, temperature, solvent volume, and stirring speed) in order to maximize OTA recovery. The optimized MAE conditions were the following: 25 mL of acetonitrile, 10 min of extraction, at 80 °C, and maximum stirring speed. Validation of the overall methodology was performed by spiking assays at five levels (0.1–3.00 ng/g). The quantification limit was 0.005 ng/g. The established method was then applied to 64 bread samples (wheat, maize, and wheat/maize bread) collected in Oporto region (Northern Portugal). OTAwas detected in 84 % of the samples with a maximum value of 2.87 ng/g below the European maximum limit established for OTA in cereal products of 3 ng/g.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method for the determination of some pesticide residues in must and wine samples was developed using solid-phase microextraction (SPME) and gas chromatography – electron capture detection (GC/ECD). The procedure only needs dilution as sample pre-treatment and is therefore simple, fast and solvent-free. Eight fungicides (vinclozolin, procymidone, iprodione, penconazole, fenarimol, folpet, nuarimol and hexaconazole), one insecticide (chlorpyriphos) and two acaricides (bromopropylate and tetradifon) can be quantified. Good linearity was observed for all the compounds in the range 5–100 µg/L. The reproducibility of the measurements was found acceptable (with RSD’s below 20%). Detection limits of 11 µg/L, on average, are sufficiently below the proposed maximum residue limits (MRL’s) for these compounds in wine. The analytical method was applied to the determination of these compounds in Portuguese must and wine samples from the Demarcated Region of Alentejo, where any residues could be detected.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The interest for environmental fate assessment of chiral pharmaceuticals is increasing and enantioselective analytical methods are mandatory. This study presents an enantioselective analytical method for the quantification of seven pairs of enantiomers of pharmaceuticals and a pair of a metabolite. The selected chiral pharmaceuticals belong to three different therapeutic classes, namely selective serotonin reuptake inhibitors (venlafaxine, fluoxetine and its metabolite norfluoxetine), beta-blockers (alprenolol, bisoprolol, metoprolol, propranolol) and a beta2-adrenergic agonist (salbutamol). The analytical method was based on solid phase extraction followed by liquid chromatography tandem mass spectrometry with a triple quadrupole analyser. Briefly, Oasis® MCX cartridges were used to preconcentrate 250 mL of water samples and the reconstituted extracts were analysed with a Chirobiotic™ V under reversed mode. The effluent of a laboratory-scale aerobic granular sludge sequencing batch reactor (AGS-SBR) was used to validate the method. Linearity (r2 > 0.99), selectivity and sensitivity were achieved in the range of 20–400 ng L−1 for all enantiomers, except for norfluoxetine enantiomers which range covered 30–400 ng L−1. The method detection limits were between 0.65 and 11.5 ng L−1 and the method quantification limits were between 1.98 and 19.7 ng L−1. The identity of all enantiomers was confirmed using two MS/MS transitions and its ion ratios, according to European Commission Decision 2002/657/EC. This method was successfully applied to evaluate effluents of wastewater treatment plants (WWTP) in Portugal. Venlafaxine and fluoxetine were quantified as non-racemic mixtures (enantiomeric fraction ≠ 0.5). The enantioselective validated method was able to monitor chiral pharmaceuticals in WWTP effluents and has potential to assess the enantioselective biodegradation in bioreactors. Further application in environmental matrices as surface and estuarine waters can be exploited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Neem (Azadirachta indica) é uma árvore indiana conhecida pela atividade pesticida e por várias atividades farmacológicas. De entre os vários compostos já isolados e estudados, a Azadiractina (AZA) foi identificada como o principal composto bioativo desta planta. Este composto apresenta uma grande diversidade de localizações nesta planta, porém assume a sua máxima concentração ao nível das sementes, porção que se apresenta também como a principal fonte de obtenção do óleo de Neem. O óleo apresenta-se como a porção menos estudada do Neem, quer ao nível do seu teor em AZA, quer ao nível das suas propriedades, nomeadamente antimicrobianas. Neste sentido, os objetivos primordiais deste estudo foram o doseamento da Azadiractina e a avaliação da atividade antimicrobiana em produtos contendo óleo de Neem. Um método analítico rápido, sensível e seletivo utilizando HPLC-UV foi desenvolvido para a identificação e quantificação da Azadiractina-A (AZA-A) e 3-tigloylazadirachtol (AZA-B) em diferentes amostras de óleo de Neem. O teor de AZA-A, B e A+B determinado nas amostras de óleo de Neem apresentou valores entre 58,53-843,42 mg/kg, 12,52-800,223 mg/kg e 104,20-1642,17 mg/kg, respetivamente. Na generalidade, os valores obtidos foram inferiores aos descritos na literatura. A partir dos resultados obtidos, verificou-se ainda que o teor destes compostos não é similar em todas as amostras, sendo este condicionado pela qualidade das sementes que deram origem ao óleo e pelo processo extrativo utilizado. Para além disso, foi possível inferir que duas das amostras testadas teriam qualidade inferior, dados os teores reduzidos de AZA que apresentavam. As diferentes amostras de óleo de Neem, bem como formulações comerciais contendo óleo de Neem, foram testadas em 14 microrganismos de forma a avaliar o seu potencial antimicrobiano. Após a análise, verificou-se atividade antimicrobiana de todas as amostras sobre todos os microrganismos testados, observando-se atividade tanto em bactérias Gram+ como Gram-. Os resultados alcançados mostraram que o óleo de Neem e as formulações comerciais contendo óleo de Neem têm um potencial antimicrobiano interessante, principalmente sobre bactérias comuns em patologias da pele. Para além disso, foi possível comprovar que, no caso do óleo de Neem, a AZA não será a principal responsável por esta atividade. Por outro lado, verificou-se que a atividade antimicrobiana das formulações comerciais não se deverá exclusivamente à presença do óleo de Neem, Doseamento da Azadiractina e avaliação da atividade antimicrobiana em produtos contendo óleo de Neem X uma vez que os valores dos halos de inibição obtidos com as formulações tenderam a ser superiores aos verificados apenas com o óleo, além de que os valores de inibição mais elevados foram observados para as formulações contendo menor percentagem de óleo de Neem incorporado. Em suma, os resultados alcançados para os diferentes produtos analisados são promissores e, na sua maioria, convergem com o que está descrito na literatura. No entanto, apesar destes resultados serem um grande contributo, mais estudos são necessários e importantes para conhecer melhor os produtos analisados e assim poder tirar o maior proveito deles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Actualmente e cada vez mais, são concebidos e utilizados programas de cálculo automático de Engenharia na realização de projectos de edifícios, que proporcionam aos engenheiros uma possibilidade avançada e rápida de execução, simulação e análise de edifícios para estruturas complexas e de elevada dimensão. Contudo, será necessário que os resultados deverão ser fiáveis de modo a não existirem consequências no comportamento real da estrutura a longo prazo. O presente relatório de estágio, refere-se à verificação aos estados limites de utilização (tensões, fendilhação e deformação) segundo o Eurocódigo 2, de uma estrutura porticada em betão armado, nomeadamente de um pórtico central pertencente a essa mesma estrutura recorrendo ao programa de cálculo automático da Autodesk o Robot Structural Analysis Professional 2014. O objectivo principal do presente trabalho consiste na comparação de resultados referente aos estados limites últimos e de utilização, pelos diferentes módulos de dimensionamento Required e Provided Reinforcement presentes no programa Robot. É destacado no final do relatório, considerando uma disposição de armadura optada analiticamente para o pórtico, uma análise comparativa de resultados referente aos estados limites de utilização entre o comando Typical Reinforcement do módulo Provided Reinforcement e por expressões analíticas. Refere-se contudo que, o procedimento do método analítico teve como base de cálculo uma aplicação desenvolvida para a verificação de elementos de betão armado aos estados limites de utilização segundo o Eurocódigo 2, com o nome de XD-Conserv tendo sido também comparado os resultados finais do mesmo.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.