4 resultados para Sampling Time Deviation

em WestminsterResearch - UK


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The cortisol awakening response (CAR) is typically measured in the domestic setting. Moderate sample timing inaccuracy has been shown to result in erroneous CAR estimates and such inaccuracy has been shown partially to explain inconsistency in the CAR literature. The need for more reliable measurement of the CAR has recently been highlighted in expert consensus guidelines where it was pointed out that less than 6% of published studies provided electronic-monitoring of saliva sampling time in the post-awakening period. Analyses of a merged data-set of published studies from our laboratory are presented. To qualify for selection, both time of awakening and collection of the first sample must have been verified by electronic-monitoring and sampling commenced within 15 min of awakening. Participants (n = 128) were young (median age of 20 years) and healthy. Cortisol values were determined in the 45 min post-awakening period on 215 sampling days. On 127 days, delay between verified awakening and collection of the first sample was less than 3 min (‘no delay’ group); on 45 days there was a delay of 4–6 min (‘short delay’ group); on 43 days the delay was 7–15 min (‘moderate delay’ group). Cortisol values for verified sampling times accurately mapped on to the typical post-awakening cortisol growth curve, regardless of whether sampling deviated from desired protocol timings. This provides support for incorporating rather than excluding delayed data (up to 15 min) in CAR analyses. For this population the fitted cortisol growth curve equation predicted a mean cortisol awakening level of 6 nmols/l (±1 for 95% CI) and a mean CAR rise of 6 nmols/l (±2 for 95% CI). We also modelled the relationship between real delay and CAR magnitude, when the CAR is calculated erroneously by incorrectly assuming adherence to protocol time. Findings supported a curvilinear hypothesis in relation to effects of sample delay on the CAR. Short delays of 4–6 min between awakening and commencement of saliva sampling resulted an overestimated CAR. Moderate delays of 7–15 min were associated with an underestimated CAR. Findings emphasize the need to employ electronic-monitoring of sampling accuracy when measuring the CAR in the domestic setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Next generation Global Navigation Satellite System (GNSS) receivers will operate in multiple navigation bands. An efficient way to achieve this with lower power and cost is to employ BandPass Sampling (BPS); nevertheless, the sampling operation injects large amounts of jitter noise, which degrades the performance of the receiver. Continuous–Time (CT) Delta–Sigma (ΔΣ) modulators are capable of suppressing this noise but the impact of clock jitter at the output of the Digital– to–Analog Converter (DAC) in the feedback path of the modulator should be taken into account. This paper presents an analytical approach for describing clock jitter in GNSS receivers when a CT–ΔΣ modulator is utilized for Analog–to–Digital Conversion (ADC). The validity of the presented approach is verified through time–domain simulations using a behavioural model of the fourth–order CT–ΔΣ modulator with 1–bit NRZ DAC feedback pulse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sediment is a major sink for heavy metals in river, and poses significant risks not only to river quality but also to aquatic and benthic organisms. At present in the UK, there are no mandatory sediment quality standards. This is partly due to insufficient toxicity data but also due to problems with identification of appropriate sediment monitoring and analytical techniques. The aim of this research was to examine the sampling different river sediment compartments in order to monitor compliance with any future UK sediment environmental quality standards (EQS). The significance of sediment physical and chemical characteristics on sampling and analysis was also determined. The Ravensbourne River, a tributary of the River Thames located in the highly urbanised South Eastern area of London was used for this study. Sediment was collected from the bed using the Van Veer grab, the bank using hand trowel, and from the water column (suspended sediment) using the time integrated suspended tube sampler between the period of July 2010 and December, 2011. The result for the total metal extraction carried out using aqua regia found that there were no significant differences in the metal concentrations retained in the different compartments by the <63μm sediment fraction but there were differences between the 63μm-2mm fractions of the bed and bank. The metal concentration in the bed, bank and suspended sediment exceeded the draft UK sediment quality guidelines. Sequential extraction was also carried out to determine metal speciation in each sediment compartment using the Maiz et al. (1997) and Tessier et al. (1979) methods. The Maiz et al. (1997) found over 80% of the metals in each sediment compartment were not bioavailable, while Tessier et al. (1979) method found most of the metals to be associated with the Fe/Mn and the residual phase. The bed sediment compartment and the <2mm (<63μm + 63μm-2mm) fraction appears to be the most suitable sediment sample for sediment monitoring from this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces a novel method of estimating theFourier transform of deterministic continuous-time signals from a finite number N of their nonuniformly spaced measurements. These samples, located at a mixture of deterministic and random time instants, are collected at sub-Nyquist rates since no constraints are imposed on either the bandwidth or the spectral support of the processed signal. It is shown that the proposed estimation approach converges uniformly for all frequencies at the rate N^−5 or faster. This implies that it significantly outperforms its alias-free-sampling-based predecessors, namely stratified and antithetical stratified estimates, which are shown to uniformly convergence at a rate of N^−1. Simulations are presented to demonstrate the superior performance and low complexity of the introduced technique.