8 resultados para cataract surgery

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS: Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bifocal diffractive IOL AT LISA 801 (Carl Zeiss Meditec, Jena, Germany), and the trifocal group, including eyes implanted with the trifocal diffractive IOL AT LISA tri 839 MP (Carl Zeiss Meditec). Analysis of visual and refractive outcomes, contrast sensitivity, ocular aberrations (OPD-Scan III; Nidek, Inc., Gagamori, Japan), and defocus curve were performed during a 3-month follow-up period. RESULTS: No statistically significant differences between groups were found in 3-month postoperative uncorrected and corrected distance visual acuity (P > .21). However, uncorrected, corrected, and distance-corrected near and intermediate visual acuities were significantly better in the trifocal group (P < .01). No significant differences between groups were found in postoperative spherical equivalent (P = .22). In the binocular defocus curve, the visual acuity was significantly better for defocus of -0.50 to -1.50 diopters in the trifocal group (P < .04) and -3.50 to -4.00 diopters in the bifocal group (P < .03). No statistically significant differences were found between groups in most of the postoperative corneal, internal, and ocular aberrations (P > .31), and in contrast sensitivity for most frequencies analyzed (P > .15). CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision over bifocal IOLs, with equivalent postoperative levels of visual and ocular optical quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To define the financial and management conditions required to introduce a femtosecond laser system for cataract surgery in a clinic using a fuzzy logic approach. METHODS: In the simulation performed in the current study, the costs associated to the acquisition and use of a commercially available femtosecond laser platform for cataract surgery (VICTUS, TECHNOLAS Perfect Vision GmbH, Bausch & Lomb, Munich, Germany) during a period of 5y were considered. A sensitivity analysis was performed considering such costs and the countable amortization of the system during this 5y period. Furthermore, a fuzzy logic analysis was used to obtain an estimation of the money income associated to each femtosecond laser-assisted cataract surgery (G). RESULTS: According to the sensitivity analysis, the femtosecond laser system under evaluation can be profitable if 1400 cataract surgeries are performed per year and if each surgery can be invoiced more than $500. In contrast, the fuzzy logic analysis confirmed that the patient had to pay more per surgery, between $661.8 and $667.4 per surgery, without considering the cost of the intraocular lens (IOL). CONCLUSION: A profitability of femtosecond laser systems for cataract surgery can be obtained after a detailed financial analysis, especially in those centers with large volumes of patients. The cost of the surgery for patients should be adapted to the real flow of patients with the ability of paying a reasonable range of cost.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To examine a single-optic accommodating intraocular lens (IOL) visual performance by correlating IOL implanted eyes’ defocus curve with the intraocular aberrometric profile and the impact on the quality of life (QOL). Methods: Prospective consecutive case series study including a total of 25 eyes of 14 patients with ages ranging between 52 and 79 years old. All cases underwent cataract surgery with implantation of the single-optic accommodating IOL Crystalens HD (Bausch & Lomb). Distance and near visual acuity outcomes, intraocular aberrations, the defocus curve and QOL (NEI VFQ-25) were evaluated 3 months after surgery. Results: A significant improvement in distance visual acuity was found postoperatively (p = 0.02). Mean postoperative LogMAR uncorrected near visual acuity was 0.44 ± 0.23 (20/30). 60% of eyes had a postoperative addition between 0 and 1.5 diopters (D). The defocus curve showed an area of maximum visual acuity for the levels of defocus corresponding to distance and intermediate vision (−1 to +0.5 D). Postoperative intermediate visual acuity correlated significantly some QOL indices (r ≥ 0.51, p ≤ 0.03; difficulty in going down steps or seeing how people react to things that patient says) as well as with J0 component of manifest cylinder. Postoperative distance-corrected near visual acuity correlated significantly with age (r = 0.65, p < 0.01). Conclusions: This accommodating IOL seems to be able to restore the distance visual function as well as to provide an improvement in intermediate and near vision with a significant impact on patient's QOL, although limited by age and astigmatism. Future studies with larger sample sizes should confirm all these trends.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL. Methods Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). Results A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. Conclusions The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the visual, refractive, contrast-sensitivity, and aberrometric outcomes during a 1-year follow-up after implantation of a trifocal intraocular lens (IOL). Setting: Premium Clinic, Teplice, Czech Republic. Design: Prospective case series. Methods: This study included eyes of patients having cataract surgery with implantation of the trifocal IOL model AT Lisa tri 839MP. Distance, intermediate (66 and 80 cm), and near (33 and 40 cm) vision; contrast sensitivity; aberrometric outcomes; and the defocus curve were evaluated during a 12-month follow-up. The level of posterior capsule opacification (PCO) was also evaluated. Results: In 120 eyes (60 patients), 1 month postoperatively, an improvement was observed in all visual parameters (P ≤ .03) except corrected near and intermediate visual acuities (both P ≥ .05). From 1 month to 12 months postoperatively, small but statistically significant changes were observed in uncorrected and corrected distance and near visual acuities (all P ≤ .03) and in uncorrected intermediate visual acuity (P = .01). In the defocus curve, no significant differences were found between visual acuities corresponding to defocus levels of −1.0 diopter (D) and −2.0 D (P = .22). The level of ocular spherical aberration decreased statistically significantly at 6 months (P < .001). Ocular and internal higher-order aberrations increased minimally but significantly from 6 to 12 months postoperatively (P < .001). The mean 12-month PCO score was 0.32 ± 0.44 (SD). Four eyes (3.3%) required neodymium:YAG capsulotomy. Conclusion: The trifocal IOL provided complete and stable visual restoration after cataract surgery during a 12-month follow-up, with good levels of visual quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.