2 resultados para Capsule polysaccharidique

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a small case series that provides preliminary evidence of the usefulness of a new capsule-anchoring device for the management of subluxated cataracts. Three eyes of 3 patients with traumatic subluxated cataract causing a significant visual loss were enrolled. Phacoemulsification was performed in all cases with implantation of a capsule-anchoring device (AssiAnchor) because partial zonular dehiscence was present. A significant visual improvement was achieved in the 3 cases. The capsular bag was well centered and the anchors firmly attached to the capsulorhexis and sclera at 12 months postoperatively. The capsule-anchoring device was helpful in managing traumatic subluxated cataracts, enabling effective centration of the intraocular lens–capsular bag complex and, consequently, effective visual restoration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the visual, refractive, contrast-sensitivity, and aberrometric outcomes during a 1-year follow-up after implantation of a trifocal intraocular lens (IOL). Setting: Premium Clinic, Teplice, Czech Republic. Design: Prospective case series. Methods: This study included eyes of patients having cataract surgery with implantation of the trifocal IOL model AT Lisa tri 839MP. Distance, intermediate (66 and 80 cm), and near (33 and 40 cm) vision; contrast sensitivity; aberrometric outcomes; and the defocus curve were evaluated during a 12-month follow-up. The level of posterior capsule opacification (PCO) was also evaluated. Results: In 120 eyes (60 patients), 1 month postoperatively, an improvement was observed in all visual parameters (P ≤ .03) except corrected near and intermediate visual acuities (both P ≥ .05). From 1 month to 12 months postoperatively, small but statistically significant changes were observed in uncorrected and corrected distance and near visual acuities (all P ≤ .03) and in uncorrected intermediate visual acuity (P = .01). In the defocus curve, no significant differences were found between visual acuities corresponding to defocus levels of −1.0 diopter (D) and −2.0 D (P = .22). The level of ocular spherical aberration decreased statistically significantly at 6 months (P < .001). Ocular and internal higher-order aberrations increased minimally but significantly from 6 to 12 months postoperatively (P < .001). The mean 12-month PCO score was 0.32 ± 0.44 (SD). Four eyes (3.3%) required neodymium:YAG capsulotomy. Conclusion: The trifocal IOL provided complete and stable visual restoration after cataract surgery during a 12-month follow-up, with good levels of visual quality.