44 resultados para PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enterovirus 71 (EV71) is one of the main causative agents of hand, foot and mouth disease (HFMD) in young children. Infections caused by EV71 could lead to many complications, ranging from brainstem encephalitis to pulmonary oedema, resulting in high mortality. Thus, rapid detection of the virus is required to enable measures to be implemented in preventing widespread transmission. Based on primers and probes targeting at the VP1 region, a real-time reverse-transcriptase polymerase chain reaction (RT-PCR) hybridization probe assay was developed for specific detection of EV71 from clinical specimens. Quantitative analysis showed that the assay was able to detect as low as 5 EV71 viral copies and EV71 was detected from 46 of the 55 clinical specimens obtained from pediatric patients suffering from HFMD during the period from 2000 to 2003 in Singapore. This study showed that the single tube real-time RT-PCR assay developed in this study can be applied as a rapid and sensitive method for specific detection of EV71 directly from clinical specimens. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent emergence of a decreased susceptibility of Neisseria gonorrhoeae strains to penicillin in New Caledonia has lead clinicians to operate a change in the treatment strategy. In addition, this important health issue has emphasized the need for a rapid means of detecting penicillin resistance in N. gonorrhoeae in order to select an effective treatment and limit the spread of resistant strains. In recent years, the use of fluorescence resonance energy transfer on the LightCycler has proven to be a valuable tool for the screening of mutations occurring in the genome of various microorganisms. In this study, we developed a real-time PCR assay coupled with a fluorometric hybridization probes system to detect a penicillin resistance-associated mutation on the N. gonorrhoeae ponA gene. Following an extensive evaluation involving 136 isolates, melting curve analysis correctly evidenced a 5 degrees C T-m shift in all N. gonorrhoeae strains possessing this mutation, as determined by conventional sequencing analysis. Moreover, the mutation profiles obtained with the real-time PCR showed good correlation with the pattern of penicillin susceptibility generated with classical antibiograms. Overall, our molecular assay allowed an accurate and reproducible determination of the susceptibility to penicillin corresponding to a mutation present in all chromosomally mediated resistant strains of N. gonorrhoeae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 36 tonsil swab samples were collected from healthy swine prior to slaughter at the abattoirs in Can tho and Tien giang provinces of Southern Vietnam, The presence of Pasteurella multocida in these samples was detected by the combination of direct cultivation and isolation, mouse inoculation and the polymerase chain reaction (PM-PCR). P. multocida was detected in 16 samples by PCR, with 17 strains ultimately isolated. All samples were negative for serogroup B by HSB-PCR and conventional serotyping, with isolates identified as A:3, D:1 or D:3. In addition, all samples were determined to be negative for the P. multocida toxin (PMT). Characterisation of isolated P, multocida by REP-PCR and biotyping revealed nine distinct REP profiles and seven biotypes among the 17 isolates. Some correlation was seen with P. multocida isolated from a previous Australian outbreak of acute swine pasteurellosis, and those isolated from fowl cholera outbreaks in Vietnamese poultry. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador: