5 resultados para Drug screening

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel and precise assay that facilitates high-throughput screening of fibrinolytic agents was developed based on the automated assessment of the euglobulin clot lysis time in microtitre plates. Euglobulin fractions from fresh plasma samples were assessed over 28 days to determine the inter-assay and intra-assay precision. The intra-assay (coefficient of variation range, 0.7-2.6%) and inter-assay precision (coefficient of variation range, 6.8-12.1%) was found to be well within limits required by the Food and Drug Administration. On day 1 and day 28, the results of the microtitre plate euglobulin clot lysis time method were compared with tissue plasminogen activator activity, plasminogen activator inhibitor activity and results produced on fibrin plates. All comparisons were found to correlate significantly. The validity of this method for assaying fibrinolytic agents was assessed by comparing dose-response curves for streptokinase produced using fibrin plates and this method. The critical influence of ambient temperature on the inter-assay reproducibility of this method was established by testing samples over a range of temperatures between 20degreesC and 40degreesC. (C) 2004 Lippincott Williams Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is a significant clinical need to identify novel ligands with high selectivity and potency for GABA(A), GABA(C) and glycine receptor Cl- channels. Two recently developed, yellow fluorescent protein variants (YFP-I152L and YFP-V163S) are highly sensitive to quench by small anions and are thus suited to reporting anionic influx into cells. The aim of this study was to establish the optimal conditions for using these constructs for high-throughput screening of GABA(A), GABA(C) and glycine receptors transiently expressed in HEK293 cells. We found that a 70% fluorescence reduction was achieved by quenching YFP-I152L with a 10 s influx of I- ions, driven by an extemal I- concentration of at least 50 mM. The fluorescence quench was rapid, with a mean time constant of 3 s. These responses were similar for all anion receptor types studied. We also show the assay is sufficiently sensitive to measure agonist and antagonist concentration-responses using either imaging- or photomultiplier-based detection systems. The robustness, sensitivity and low cost of this assay render it suited for high-throughput screening of transiently expressed anionic ligand-gated channels. (c) 2005 Elsevier Ireland Ltd. All rights reserved.