143 resultados para Diagnostic, methods comparison

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The abundance and activity of the prothrombin activator (pseutarin C) within the venom of the Eastern brown snake (Pseudonaja textilis textilis) is the primary determinant of its coagulation potency. Textilinin-1, also in this venom, is a plasmin inhibitor which is thought to exert its toxic effects through the slowing of fibrinolysis. The aim of this report is to determine if there are differences in the potency of the venom from Eastern brown snakes collected from South Australia (SA) compared to those from Queensland (QLD). A concentration of 0.4 mu g/ml venom protein from six QLD specimens clotted citrated plasma in an average time of 21.4 +/- 3.3 s compared to 68.7 +/- 2.4 s for the same amount of SA venom (averaged for six individuals). The more potent procoagulant activity of the QLD venom was measured between 0.4 and 94 mu g/ml venom protein in plasma. The anti-plasmin activity of textilinin was also greater in the venom of the snakes collected from QLD, causing full inhibition of plasmin at approximately 1.88 mu g/ml of venom protein compared to approximately 7.5 mu g/ml for the SA venoms. It is concluded that geographic differentiation of the Eastern brown snakes results in significant differences venom potency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This paper describes SeqDoC, a simple, web-based tool to carry out direct comparison of ABI sequence chromatograms. This allows the rapid identification of single nucleotide polymorphisms (SNPs) and point mutations without the need to install or learn more complicated analysis software. Results: SeqDoC produces a subtracted trace showing differences between a reference and test chromatogram, and is optimised to emphasise those characteristic of single base changes. It automatically aligns sequences, and produces straightforward graphical output. The use of direct comparison of the sequence chromatograms means that artefacts introduced by automatic base-calling software are avoided. Homozygous and heterozygous substitutions and insertion/deletion events are all readily identified. SeqDoC successfully highlights nucleotide changes missed by the Staden package 'tracediff' program. Conclusion: SeqDoC is ideal for small-scale SNP identification, for identification of changes in random mutagenesis screens, and for verification of PCR amplification fidelity. Differences are highlighted, not interpreted, allowing the investigator to make the ultimate decision on the nature of the change.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the assessment and validation of an NS1 epitope-blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to West Nile virus (WNV) in macaques. Sera from naturally infected Macaca nemestrina were tested by ELISA and plaque reduction neutralization test (PRNT). Results were correlated with hemagglutination inhibition (HAI) data. Our results demonstrate that the blocking ELISA rapidly and specifically detects WNV infection in M. nemestrina. In addition, the diagnostic value of 7 commercially available immunoassays (PanBio immunoglobulin [Ig] M ELISA, PanBio IgG ELISA, PanBio immunofluorescence assay (IFA), InBios IgG ELISA, InBios IgM ELISA, Focus Diagnostics IgG ELISA, and Focus Diagnostics IgM ELISA) in M. nemestrina was evaluated and compared with that of the epitope-blocking ELISA. The PanBio IgG ELISA was found to effectively diagnose WNV exposure in M. nemestrina. Further, PanBio IFA slides are fast and reliable screening tools for diagnosing flaviviral exposure in M. nemestrina.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective To improve the accuracy and completeness of reporting of studies of diagnostic accuracy, to allow readers to assess the potential for bias in a study, and to evaluate a study's generalisability. Methods The Standards for Reporting of Diagnostic Accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a two day consensus meeting, with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. Results The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25 item checklist, by using evidence, whenever available. A prototype of a flow diagram provides information about the method of patient recruitment, the order of test execution, and the numbers of patients undergoing the test under evaluation and the reference standard, or both. Conclusions Evaluation of research depends on complete and accurate reporting. If medical journals adopt the STARD checklist and flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The quality of reporting of studies of diagnostic accuracy is less than optimal. Complete and accurate reporting is necessary to enable readers to assess the potential for bias in the study and to evaluate the generalisability of the results. A group of scientists and editors has developed the STARD (Standards for Reporting of Diagnostic Accuracy) statement to improve the reporting the quality of reporting of studies of diagnostic accuracy. The statement consists of a checklist of 25 items and flow diagram that authors can use to ensure that all relevant information is present. This explanatory document aims to facilitate the use, understanding and dissemination of the checklist. The document contains a clarification of the meaning, rationale and optimal use of each item on the checklist, as well as a short summary of the available evidence on bias and applicability. The STARD statement, checklist, flowchart and this explanation and elaboration document should be useful resources to improve reporting of diagnostic accuracy studies. Complete and informative reporting can only lead to better decisions in healthcare.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recently, a 3D phantom that can provide a comprehensive and accurate measurement of the geometric distortion in MRI has been developed. Using this phantom, a full assessment of the geometric distortion in a number of clinical MRI systems (GE and Siemens) has been carried out and detailed results are presented in this paper. As expected, the main source of geometric distortion in modern superconducting MRI systems arises from the gradient field nonlinearity. Significantly large distortions with maximum absolute geometric errors ranged between 10 and 25 mm within a volume of 240 x 240 x 240 mm(3) were observed when imaging with the new generation of gradient systems that employs shorter coils. By comparison, the geometric distortion was much less in the older-generation gradient systems. With the vendor's correction method, the geometric distortion measured was significantly reduced but only within the plane in which these 2D correction methods were applied. Distortion along the axis normal to the plane was, as expected, virtually unchanged. Two-dimensional correction methods are a convenient approach and in principle they are the only methods that can be applied to correct geometric distortion in a single slice or in multiple noncontiguous slices. However, these methods only provide an incomplete solution to the problem and their value can be significantly reduced if the distortion along the normal of the correction plane is not small. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Videoconferencing has become a routine technique for the post-acute burns care of children in Queensland. We compared the agreement between clinical assessments conducted via videoconference and assessments conducted in the conventional, face-to-face manner (FTF). A total of 35 children with a previous burn injury were studied. Twenty-five children received three consecutive assessments: first FTF by a consultant in the outpatient department, then by a second consultant who reviewed the patient via videoconference, and then by the second consultant in person. The second consultant also reviewed another 10 children twice. At each review, the following variables were measured: scar colour, scar thickening, contractures, range of motion, the patient's level of general activity, any breakdown of the graft site, and adequacy of the consultation. Agreement between the two consultants when seeing patients FTF was moderately high, with an overall concordance of 85%. When videoconferencing was used, the level of agreement was almost the same, at 84%. If one consultant reviewed patients FTF first and then via videoconference, the overall concordance was 98%; if the process was reversed, the overall concordance was 97%. This study confirms that the quality of information collected during a videoconference appointment is comparable to that collected during a traditional, FTF appointment for a follow-up burns consultation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In recent times, PSA screening and a substantial increase in prostate needle biopsies have not only resulted in detection of minute foci of cancer but have also very likely resulted in increased detection of atypical glandular proliferations. Not uncommonly, there are only a limited number of atypical glands in these biopsies, and these require careful evaluation to enable an accurate diagnosis. We describe diagnostic implications, use of immunohistochemistry, and clinical significance of these lesions. Foci of atypical glands, also labeled atypical small acinar proliferation of uncertain significance, have features suspicious for but not diagnostic of cancer. Atypical foci include a broad group of lesions of differing clinical significance. These include benign, small acinar proliferations mimicking prostate cancer and atypical glandular proliferations suspicious for carcinoma. Definite diagnosis requires accurate histopathologic assessment and judicious use of immunohistochemistry. Patients with atypical glands on prostate needle biopsy have a high risk for harboring cancer and therefore have an increased risk for having cancer detected in subsequent biopsies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: Inpatient length of stay (LOS) is an important measure of hospital activity, health care resource consumption, and patient acuity. This research work aims at developing an incremental expectation maximization (EM) based learning approach on mixture of experts (ME) system for on-line prediction of LOS. The use of a batchmode learning process in most existing artificial neural networks to predict LOS is unrealistic, as the data become available over time and their pattern change dynamically. In contrast, an on-line process is capable of providing an output whenever a new datum becomes available. This on-the-spot information is therefore more useful and practical for making decisions, especially when one deals with a tremendous amount of data. Methods and material: The proposed approach is illustrated using a real example of gastroenteritis LOS data. The data set was extracted from a retrospective cohort study on all infants born in 1995-1997 and their subsequent admissions for gastroenteritis. The total number of admissions in this data set was n = 692. Linked hospitalization records of the cohort were retrieved retrospectively to derive the outcome measure, patient demographics, and associated co-morbidities information. A comparative study of the incremental learning and the batch-mode learning algorithms is considered. The performances of the learning algorithms are compared based on the mean absolute difference (MAD) between the predictions and the actual LOS, and the proportion of predictions with MAD < 1 day (Prop(MAD < 1)). The significance of the comparison is assessed through a regression analysis. Results: The incremental learning algorithm provides better on-line prediction of LOS when the system has gained sufficient training from more examples (MAD = 1.77 days and Prop(MAD < 1) = 54.3%), compared to that using the batch-mode learning. The regression analysis indicates a significant decrease of MAD (p-value = 0.063) and a significant (p-value = 0.044) increase of Prop(MAD