55 resultados para Sewer reactor

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effect of mass transfer limitations in the three-phase oxidation of cinnamyl alcohol carried out in toluene and an ionic liquid (1-butyl-3-methyl-imidazolium bis(trifluoromethylsulphonyl)imide), studies have been performed in a rotating disc reactor and compared with those carried out in a stirred tank reactor where mass transfer effects are considered negligible. High catalyst efficiencies are found in the stirred tank reactor with the use of both ionic liquid and toluene, although there is a decrease in rate for the ionic liquid reactions. In contrast, internal pore diffusion limits the reaction in both solvents in the rotating disc reactor. This mass transfer resistance reduces the problem of overoxidation of the metal surface when the reaction is carried out in toluene, leading to significantly higher rates of reaction than expected, although at the cost of decreased selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin-zone TAP reactor is presented as a basis of the new state-by-state transient screening approach which has been proposed by the authors for non-steady-state kinetic characterization of industrial catalysts. The general thin-zone TAP reactor model is described, and its mathematical status is justified analytically. It is shown that this model provides high enough accuracy to be applicable in the wide conversion interval (up to 90%), which is an important advantage of this approach compared with the traditional differential reactor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dielectric barrier discharge (DBD) generated by flowing helium between the parallel-plate electrodes of an open air reactor has been characterized using time resolved optical and electrical measurements. A sinusoidal voltage of up to 5 kV (peak to peak) of frequencies from 3 to 50 kHz has been applied to the discharge electrodes. The helium flow rate is varied up to 10 litre min(-1). The adjustment of flow rate allows the creation of uniform DBDs with optimized input power equal to 120 +/- 10 mW cm(-3). At flow rates from 4 to 6 litre min(-1) a uniform DBD is obtained. The maxima in the line intensities of N-2(+) and helium at 391.4 nm and 706.5 nm, respectively, 2 under those conditions indicate the importance of helium metastables and He-2(+) in sustaining such a discharge. The power efficiency and discharge 2 current show maxima when the DBD In He/air is uniform. The gas temperature during the discharge has been measured as 360 +/- 20 K.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on time-dependent population distributions of excited rotational states of hydrogen in a capacitively coupled RF discharge. The common model to obtain the gas temperature from the rotational distribution is not applicable at all times during the discharge cycle due to the time dependence of the EEDF. The apparent temperature within a cycle assumes values between 350 K and 450 K for the discharge parameters of this experiment. We discuss the optimum time window within the discharge cycle that yields the best approximation to the actual temperature. Erroneous results can be obtained, in principle, with time-integrated measurements; we find, however, that in the present case the systematic error amounts to only approximately 20 K. This is due to the fact that the dominant contribution to the average intensity arises during that time window for which the assumptions underlying the analysis are best fulfilled. A similar analysis can be performed for N+2 rotational bands with a small amount of nitrogen added to the discharge gas. These populations do not exhibit the time variations found in the case of H2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dilute acid hydrolysis of grass and cellulose with phosphoric acid was undertaken in a microwave reactor system. The experimental data and reaction kinetic analysis indicate that this is a potential process for cellulose and hemi-cellulose hydrolysis, due to a rapid hydrolysis reaction at moderate temperatures. The optimum conditions for grass hydrolysis were found to be 2.5% phosphoric acid at a temperature of 175 degrees C. It was found that sugar degradation occurred at acid concentrations greater than 2.5% (v/v) and temperatures greater than 175 degrees C. In a further series of experiments, the kinetics of dilute acid hydrolysis of cellulose was investigated varying phosphoric acid concentration and reaction temperatures. The experimental data indicate that the use of microwave technology can successfully facilitate dilute acid hydrolysis of cellulose allowing high yields of glucose in short reaction times. The optimum conditions gave a yield of 90% glucose. A pseudo-homogeneous consecutive first order reaction was assumed and the reaction rate constants were calculated as: k(1) = 0.0813 s(-1); k(2) = 0.0075 s(-1), which compare favourably with reaction rate constants found in conventional non-microwave reaction systems. The kinetic analysis would indicate that the primary advantages of employing microwave heating were to: achieve a high rate constant at moderate temperatures: and to prevent 'hot spot' formation within the reactor, which would have cause localised degradation of glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The H+NO2 titration scheme for the determination of atomic hydrogen densities within a microwave excited flow tube reactor has been investigated by laser-induced fluorescence spectroscopy in the vacuum UV. Absolute hydrogen densities are determined on the basis of calibration by Rayleigh scattering from argon. The measurement is performed at a gas mixture containing 0.5% of D2 added to the main gas H2. The ground state density of the hydrogen atoms generated in the flow tube reactor was inferred from the fluorescence radiation of the spectrally shifted optically thin D-Lyman-a transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a review of applicable sewer rehabilitation options using trenchless technology in Malaysia. The typical problems faced in wastewater collection systems are analysed and factors that determine the selection method are outlined. This study also highlights the necessary steps to be taken prior to the rehabilitation work. The trenchless technology reviewed here comprises repair, renovation and replacement options. The cost-effectiveness of different rehabilitation methods was identified to assess the economic viability of various options in the Malaysian context. This study reveals that not all the trenchless technologies available in the market are suitable for use in Malaysia, mainly due to incompatibility of the rehabilitation materials used. Furthermore, as trenchless rehabilitation generally involves higher capital outlay than open-cut methods, the choice of rehabilitation method has to be made on a case-to-case basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After assuming control of Malaysia's sewer systems, Indah Water Konsortium Sdn. Bhd. commissioned a study into the available sewer rehabilitation techniques in the markety with the intention of finding suitable methods to rehabilitate sewers in and around Malaysia. This report outlines the key findings of the study, focusing on the applicable sewer rehabilitation techniques which use Trenchless Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary medical science is reliant upon the rational selection and utilization of devices, and therefore, an increasing need has developed for in vitro systems aimed at replicating the conditions to which urological devices will be subjected to during their use in vivo. We report the development and validation of a novel continuous flow encrustation model based on the commercially available CDC biofilm reactor. Proteus mirabilis-induced encrustation formation on test biomaterial sections under varying experimental parameters was analyzed by X-ray diffraction, infrared- and Raman spectroscopy and by scanning electron microscopy. The model system produced encrusted deposits similar to those observed in archived clinical samples. Results obtained for the system are highly reproducible with encrustation being rapidly deposited on test biomaterial sections. This model will have utility in the rapid screening of encrustation behavior of biomaterials for use in urological applications. (C) 2010 Wiley Periodicals. Inc. J Biomed Mater Res Part B: Appl Biomater 93B: 128-140, 2010