73 resultados para Sensitivity and Specificity

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We assessed ten trophodynamic indicators of ecosystem status for their sensitivity and specificity to fishing management using a size-resolved multispecies fish community model. The responses of indicators to fishing depended on effort and the size selectivity (sigmoid or Gaussian) of fishing mortality. The highest specificity against sigmoid (trawl-like) size selection was seen from inverse fishing pressure and the large fish indicator, but for Gaussian size selection, the large species indicator was most specific. Biomass, mean trophic level of the community and of the catch, and fishing in balance had the lowest specificity against both size selectivities. Length-based indicators weighted by biomass, rather than abundance, were more sensitive and specific to fishing pressure. Most indicators showed a greater response to sigmoid than Gaussian size selection. Indicators were generally more sensitive at low levels of effort because of nonlinear sensitivity in trophic cascades to fishing mortality. No single indicator emerged as superior in all respects, so given available data, multiple complementary indicators are recommended for community monitoring in the ecosystem approach to fisheries management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Predictive validity of the Stanford-Binet Intelligence Scale Fourth Edition (S-B IV) from age 3 years to ages 4-5 years was evaluated with biologically "at risk" children without major sensory or motor impairments (n = 236). Using the standard scoring, children with full scale IQ <or = 84 on the Wechsler Preschool and Primary Scale of Intelligence at age 4-5 years were poorly identified (sensitivity 54%) from the composite S-B IV score at age 3. However, sensitivity improved greatly to 78% by including as a predictor the number of subtests the child was actually able to perform at age 3 years. Measures from the Home Screening Questionnaire and ratings of mother-child interaction further improved sensitivity to 83%. The standard method for calculating the composite score on the S-B IV excludes subtests with a raw score of 0, which overestimates cognitive functioning in young biologically high risk children. Accuracy of early identification was improved significantly by considering the number of subtests the child did not perform at age 3 years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A biochip based on surface plasmon resonance was fabricated to detect prostate specific antigen-a1-antichymotrypsin (PSA-ACT complex) in both HBS buffer and human serum. To reduce non-specific binding and steric hindrance effect, the chemical surface of the sensor chips was constructed by using various oligo(ethylene glycol) mixtures of different molar ratios of HS(CH2)11(OCH2CH2)6OCH2COOH and HS(CH2)11(OCH2CH2)3OH. The self-assembled monolayers were biotinylated to facilitate the immobilization of streptavidin. Using the chip surfaces, PSA-ACT complex in HBS buffer and human serum was detected at 20.7 and 47.5 ng/ml by primary immunoresponse, respectively. However, the limit of detection could be simply enhanced by a sandwich strategy to improve the sensitivity and specificity of the immunoassay. An intact PSA polyclonal antibody was used as an amplifying agent in the strategy. As a result, PSA-ACT complex concentrations as low as 10.2 and 18.1 ng/ml were found in the HBS buffer and human serum sample, respectively. The result indicates that this approach could satisfy our goal without modifying the secondary interactant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Okadaic acid (OA) and structurally related toxins dinophysistoxin-1 (DTX-1), and DTX-2, are lipophilic marine biotoxins. The current reference method for the analysis of these toxins is the mouse bioassay (MBA). This method is under increasing criticism both from an ethical point of view and because of its limited sensitivity and specificity. Alternative replacement methods must be rapid, robust, cost effective, specific and sensitive. Although published immuno-based detection techniques have good sensitivities, they are restricted in their use because of their inability to: (i) detect all of the OA toxins that contribute to contamination; and (ii) factor in the relative toxicities of each contaminant. Monoclonal antibodies (MAbs) were produced to OA and an automated biosensor screening assay developed and compared with ELISA techniques. The screening assay was designed to increase the probability of identifying a MAb capable of detecting all OA toxins. The result was the generation of a unique MAb which not only cross-reacted with both DTX-1 and DTX-2 but had a cross-reactivity profile in buffer that reflected exactly the intrinsic toxic potency of the OA group of toxins. Preliminary matrix studies reflected these results. This antibody is an excellent candidate for the development of a range of functional immunochemical-based detection assays for this group of toxins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to introduce specificity for Mycobacterium avium subsp. paratuberculosis prior to a phage amplification assay, various magnetic-separation approaches, involving either antibodies or peptides, were evaluated in terms of the efficiency of capture (expressed as a percentage) of M. avium subsp. paratuberculosis cells and the percentage of nonspecific binding by other Mycobacterium spp. A 50:50 mixture of MyOne Tosylactivated Dynabeads coated with the chemically synthesized M. avium subsp. paratuberculosis-specific peptides biotinylated aMp3 and biotinylated aMptD (i.e., peptide-mediated magnetic separation [PMS]) proved to be the best magnetic-separation approach for achieving 85 to 100% capture of M. avium subsp. paratuberculosis and minimal (<1%) nonspecific recovery of other Mycobacterium spp. (particularly if beads were blocked with 1% skim milk before use) from broth samples containing 103 to 104 CFU/ml. When PMS was coupled with a recently optimized phage amplification assay and used to detect M. avium subsp. paratuberculosis in 50-ml volumes of spiked milk, the mean 50% limit of detection (LOD50) was 14.4 PFU/50 ml of milk (equivalent to 0.3 PFU/ml). This PMS-phage assay represents a novel, rapid method for the detection and enumeration of viable M. avium subsp. paratuberculosis organisms in milk, and potentially other sample matrices, with results available within 48 h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to validate the application of a commercially available multiplex reverse transcription polymerase chain reaction (RT-PCR) assay [He-mavision-7 System] for the seven most common leukemia translocations for routine molecular diagnostic hematopathology practice. A total of 98 samples, comprising four groups, were evaluated: Group 1, 16 diagnostic samples molecularly positive by our existing laboratory-developed assays for PML-RARalpha/t (15; 17) or BCR-ABL/t (9;22); Group 2, 51 diagnostic samples negative by our laboratory-developed assays for PML-RARalpha/t (15;17) or BCR-ABL/t (9;22); Group 3, 21 prospectively analyzed diagnostic cases, without prior molecular studies; and Group 4, 10 minimal residual disease (MRD) samples. Analysis of the two previously studied cohorts (Groups 1 and 2) confirmed the diagnostic sensitivity and specificity of the multiplex assay with regard to these two translocations. Additionally, however, in the

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ionic liquids have been used in combination with ball milling on a range of chlorophosphoramidite reagents to phosphitylate nucleosides and 2-deoxynucleosides. The enhanced stability offered by the ionic liquid mediated processes combined with efficient mass transfer induced by ball milling has enabled excellent yields to be obtained even when using small dialkyl amino groups as well as the more commonly used diisopropylamino protection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan™ and minor groove binder (MGB™) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probebased real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. Methods/design: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. Dissemination: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two families of membrane enzymes catalyze the initiation of the synthesis of O-antigen lipopolysaccharide. The Salmonella enterica Typhimurium WbaP is a prototypic member of one of these families. We report here the purification and biochemical characterization of the WbaP C-terminal (WbaP(CT)) domain harboring one putative transmembrane helix and a large cytoplasmic tail. An N-terminal thioredoxin fusion greatly improved solubility and stability of WbaP(CT) allowing us to obtain highly purified protein. We demonstrate that WbaP(CT) is sufficient to catalyze the in vitro transfer of galactose (Gal)-1-phosphate from uridine monophosphate (UDP)-Gal to the lipid carrier undecaprenyl monophosphate (Und-P). We optimized the in vitro assay to determine steady-state kinetic parameters with the substrates UDP-Gal and Und-P. Using various purified polyisoprenyl phosphates of increasing length and variable saturation of the isoprene units, we also demonstrate that the purified enzyme functions highly efficiently with Und-P, suggesting that the WbaP(CT) domain contains all the essential motifs to catalyze the synthesis of the Und-P-P-Gal molecule that primes the biosynthesis of bacterial surface glycans.