111 resultados para Pcr polymerase chaim reaction

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The bacterium Coxiella burnetii, which has a wide host range, causes Q fever. Infection with C burnetii can cause abortions, stillbirth, and the delivery of weak offspring in ruminants. Coxiella burnetii infection is zoonotic, and in human beings it can cause chronic, potentially fatal disease. Real-time polymerase chain reaction (PCR) is increasingly being used to detect the organism and to aid in diagnosis both in human and animal cases. Many different real-time PCR methods, which target different genes, have been described. To assess the comparability of the C. burnetii real-time PCR assays in use in different European laboratories, a panel of nucleic acid extracts was dispatched to 7 separate testing centers. The testing centers included laboratories from both human and animal health agencies. Each laboratory tested the samples using their in-house real-time PCR methods. The results of this comparison show that the most common target gene for real-time PCR assays is the IS1111 repeat element that is present in multiple copies in the C. burnetii genome. Many laboratories also use additional real-time PCR tests that target single-copy genes. The results of the current study demonstrate that the assays in use in the different laboratories are comparable, with general agreement of results for the panel of samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel assay for the pan-serotypic detection of foot-and-mouth disease virus (FMDV) was designed using a 5' conjugated minor groove binder (MGB) probe real-time RT-PCR system. This assay targets the 3D region of the FMDV genome and is capable of detecting 20 copies of a transcribed RNA standard. The linear range of the test was eight logs from 2 x 10(1) to 2 x 10(8) copies and amplification time was approximately 2 h. Using a panel of 83 RNA samples from representative FMDV isolates, the diagnostic sensitivity of this test was shown to be equivalent to a TaqMan real-time RT-PCR that targets the 5' untranslated region of FMDV. Furthermore, the assay does not detect viruses causing similar clinical diseases in pigs such as swine vesicular disease virus and vesicular stomatitis virus, nor does it detect marine caliciviruses causing vesicular exanthema. The development of this assay provides a useful tool for the differential diagnosis of FMD, potentially for use in statutory or emergency testing programmes, or for detection of FMDV RNA in research applications. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reliable detection of JAK2-V617F is critical for accurate diagnosis of myeloproliferative neoplasms (MPNs); in addition, sensitive mutation-specific assays can be applied to monitor disease response. However, there has been no consistent approach to JAK2-V617F detection, with assays varying markedly in performance, affecting clinical utility. Therefore, we established a network of 12 laboratories from seven countries to systematically evaluate nine different DNA-based quantitative PCR (qPCR) assays, including those in widespread clinical use. Seven quality control rounds involving over 21,500 qPCR reactions were undertaken using centrally distributed cell line dilutions and plasmid controls. The two best-performing assays were tested on normal blood samples (n=100) to evaluate assay specificity, followed by analysis of serial samples from 28 patients transplanted for JAK2-V617F-positive disease. The most sensitive assay, which performed consistently across a range of qPCR platforms, predicted outcome following transplant, with the mutant allele detected a median of 22 weeks (range 6-85 weeks) before relapse. Four of seven patients achieved molecular remission following donor lymphocyte infusion, indicative of a graft vs MPN effect. This study has established a robust, reliable assay for sensitive JAK2-V617F detection, suitable for assessing response in clinical trials, predicting outcome and guiding management of patients undergoing allogeneic transplant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mycoplasma pneumoniae (M. pneumoniae) is a common pathogen in cases of atypical pneumonia. Most individuals with Mycoplasma pneumonia run a benign course, with non-specific symptoms of malaise, fever and non-productive cough that usually resolve with no long-term sequelae. Acute lung injury is not commonly seen in Mycoplasma pneumonia. We report a case of acute respiratory distress syndrome cause by M. pneumoniae diagnosed by quantitative real-time polymerase chain reaction (RT-PCR).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phenotypic identification of Gram-negative bacteria from respiratory specimens of patients with cystic fibrosis carries a high risk of misidentification. Molecular identification techniques that use single-gene targets are also susceptible to error, including cross-reaction issues with other Gram-negative organisms. In this study, we have designed a Pseudomonas aeruginosa duplex real-time polymerase chain reaction (PCR) (PAduplex) assay targeting the ecfX and the gyrB genes. The PAduplex was evaluated against a panel of 91 clinical and environmental isolates that were presumptively identified as P. aeruginosa. The results were compared with those obtained using a commercial biochemical identification kit and several other P. aeruginosa PCR assays. The results showed that the PAduplex assay is highly suitable for routine identification of P. aeruginosa isolates from clinical or environmental samples. The 2-target format provides simultaneous confirmation of P. aeruginosa identity where both the ecfX and gyrB PCR reactions are positive and may also reduce the potential for false negatives caused by sequence variation in primer or probe targets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. 

Objective: Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. 

Design: Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. 

Setting: Critical care departments within NHS hospitals in the north-west of England. 

Participants: Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. 

Main outcome measures: SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. 

Results: Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4–16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. 

Conclusion: SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prevalence of factor V (FV) Leiden among normal populations has primarily been determined using blood donors. This control group is carefully selected and therefore may not accurately reflect the true prevalence within the population. We assessed the prevalence of FV Leiden within the Irish population using Guthrie card samples randomly selected from all newborns. We compared this result with the prevalence of FV Leiden within blood donors. A novel nested polymerase chain reaction (PCR) method for FV Leiden was developed for analysis of the Guthrie card samples. There was no significant difference between the allele frequency within the Guthrie card samples and blood donors (2.07% vs. 2.35%, P = 0.66)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prothrombin G20210A polymorphism is associated with a threefold-increased risk of venous thrombosis. There is considerable variation in the reported prevalence of this polymorphism within normal populations, ranging from 0 to 6.5%. The prevalence within the Irish population has not been determined. A restriction fragment length polymorphism (RFLP)-based assay is commonly used for the detection of the prothrombin 20210A allele. This assay does not include a control restriction digest fragment and, consequently, failure of the enzyme activity or lack of addition of enzyme to the sample cannot be distinguished from wild-type prothrombin. We developed a RFLP-based assay, which incorporates an invariant digest site, resulting in the generation of a control digest fragment. Furthermore, we developed a nested polymerase chain reaction (PCR) method for the amplification and digestion of poor-quality or low-concentration DNA. In the Irish population studied, five of 385 (1.29%) were heterozygous and one patient was homozygous for the prothrombin 20210A polymorphism. This is the first reported data on an Irish or Celtic population and suggests that the allele frequency is similar to Anglo-Saxon populations. The nested PCR method successfully amplified and digested 100/100 (100%) of the archived samples; none of these samples could be analyzed by the standard single-round PCR method. In conclusion, nested PCR should be considered in the analysis of archived samples. Single-round PCR is appropriate for recently collected samples; however, an invariant control digest site should be incorporated in RFLP-based assays to validate the integrity of the digestion enzyme and limit the risk of false-negative results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 12 amino acid sequence from the adenovirus 12 E1B protein is homologous at the protein level with a similar 12-mer derived from the wheat protein A-gliadin. It has been suggested that exposure to Ad 12 could sensitise individuals to gliadins with resultant gluten sensitive enteropathy. In this study, the polymerase chain reaction (PCR) was used to analyse duodenal biopsy tissue from patients with coeliac disease for the presence of Ad 12. The sensitivity of the assay system was at least 1 in 10(5) cells and specificity was confirmed both by probing with an internal oligonucleotide and by direct sequencing. Ad 12 sequences were detected in three of 17 patients with adult coeliac disease and in five of 16 adult controls with normal duodenal biopsies. Since exposure to the virus would be predicted to occur in infancy we also studied patients with childhood coeliac disease diagnosed at less than 1 year of age. Ad 12 was positive in three of 10 childhood coeliac patients and one of seven controls. In addition, we studied a cohort of patients who presented with a diarrhoeal illness and associated anti alpha gliadin antibodies in 1983. These patients had duodenal biopsies performed at this time. One of three patients with abnormal histology had detectable Ad 12 while two of 14 with normal findings were positive for Ad 12. Finally, the potential oncogenic nature of Ad 12 prompted examination of a group of patients with intestinal tumours. Ad 12 DNA was, however, in only two of 19 tumour samples tested. These data indicate that Ad 12 can be successfully detected using PCR on paraffin embedded tissue. Furthermore, Ad 12 was detected at a relatively high level in normal duodenum. The results do not, however, support the hypothesis that prior exposure to Ad 12 is implicated in the pathogenesis of coeliac disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 3-year old child with juvenile chronic myeloid leukaemia received a T cell-depleted BMT from a male unrelated donor. There was early graft failure associated with increasing splenomegaly and hypersplenism. Splenectomy was performed 53 days post-transplant and was followed by autologous marrow recovery with return of leukaemia. A second unrelated donor BMT was performed 9 months later using T cell-replete marrow from a similarly matched female donor. Grade 2 GVHD involving the skin and gut responded to treatment with steroids. Chimaerism was assessed using Y-specific polymerase chain reaction (PCR) and microsatellites. Samples taken at the time of splenectomy showed no donor marrow engraftment but there was significant engraftment in the spleen. Following the second transplant, donor-type haematopoiesis was documented using a panel of microsatellite probes. The patient remains well 6 months after transplant. Splenectomy should be considered prior to transplant in patients with significant splenomegaly and hypersplenism. Partial chimaerism in the spleen, but not bone marrow, post-BMT, has not previously been documented. PCR technology is a useful and highly sensitive way to assess chimaerism post-BMT and is informative in sex-matched cases, whilst the small amount of material required is advantageous in paediatric patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of mixed hematopoietic chimerism (MC) after allogeneic bone marrow transplantation remains unknown. Increasingly sensitive detection methods have shown that MC occurs frequently. We report a highly sensitive novel method to assess MC based on the polymerase chain reaction (PCR). Simple dinucleotide repeat sequences called microsatellites have been found to vary in their repeat number between individuals. We use this variation to type donor-recipient pairs following allogeneic BMT. A panel of seven microsatellites was used to distinguish between donor and recipient cells of 32 transplants. Informative microsatellites were subsequently used to assess MC after BMT in this group of patients. Seventeen of the 32 transplants involved a donor of opposite sex; hence, cytogenetics and Y chromosome-specific PCR were also used as an index of chimerism in these patients. MC was detected in bone marrow aspirates and peripheral blood in 18 of 32 patients (56%) by PCR. In several cases, only stored slide material was available for analysis but PCR of microsatellites or Y chromosomal material could be used successfully to assess the origin of cells in this archival material. Cytogenetic analysis was possible in 17 patients and MC was detected in three patients. Twelve patients received T-cell-depleted marrow and showed a high incidence of MC as revealed by PCR (greater than 80%). Twenty patients received unmanipulated marrow, and while the incidence of MC was lower (44%), this was a high percentage when compared with other studies. Once MC was detected, the percentages of recipient cells tended to increase. However, in patients exhibiting MC who subsequently relapsed, this increase was relatively sudden. The overall level of recipient cells in the group of MC patients who subsequently relapsed was higher than in those who exhibited stable MC. Thus, while the occurrence of MC was not indicative of a poor prognosis per se, sudden increases in the proportions of recipient cells may be a prelude to graft rejection or relapse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a case of acute lymphoblastic leukaemia relapsing after allogeneic bone marrow transplantation in which the polymerase chain reaction (PCR) was used to assess chimeric status. This technique demonstrated the progressive reappearance of host cells prior to clinical relapse. The relapse was of host cell origin as shown by the presence of female (recipient) metaphases containing an abnormal chromosomal marker (iso 9q) which had also been present at initial diagnosis. The emergence of host cells in this case, detected only by PCR techniques but not by cytogenetic methods, appeared to herald overt relapse. PCR analysis provides a sensitive tool for detecting a progressive rise in host cell numbers which may predict clinical relapse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chimaerism was assessed in five recipients following sex mismatched allogeneic bone marrow transplantation. Techniques included karyotyping of bone marrow cells, dot blot DNA analysis of blood and bone marrow suspensions, and in vitro amplification of DNA by the polymerase chain reaction (PCR) using blood and bone marrow suspensions and stored bone marrow slides. Results of karyotypic analysis suggested complete chimaerism in four patients, while in one patient mixed chimaerism was detected. Mixed chimaerism was also detected, however, in a second patient using PCR and confirmed by dot blot analysis on all tissues examined. PCR is a sensitive tool for investigation of chimaerism following bone marrow transplantation. Since this technique does not require radioactivity, it is an attractive method for use in a clinical laboratory. This technique represents a further development in the use of DNA methodologies in the assessment of haematological disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorescence in situ hybridization (FISH) for FOXO1 gene rearrangement and reverse transcription-polymerase chain reaction (PCR) for PAX3/7-FOXO1 fusion transcripts have become routine ancillary tools for the diagnosis of alveolar rhabdomyosarcomas (ARMS). Here we summarize our experience of these adjunct diagnostic modalities at a tertiary center, presenting the largest comparative series of FISH and PCR for suspected or possible ARMS to date. All suspected or possible ARMS tested by FISH or PCR for FOXO1 rearrangement or PAX3/7-FOXO1 fusion transcripts over a 7-year period were included. FISH and PCR results were correlated with clinical and histologic findings. One hundred samples from 95 patients had FISH and/or PCR performed. FISH had higher rates of technical success (96.8 %) compared with PCR (88 %). Where both tests were utilized successfully, there was high concordance rate between them (94.9 %). In 24 histologic ARMS tested for FISH or PCR, 83.3 % were translocation-positive (all for PAX3-FOXO1 by PCR) and included 3 histologic solid variants. In 76 cases where ARMS was excluded, there were 3 potential false-positive cases with FISH but none with PCR. PCR had similar sensitivity (85.7 %) and better specificity (100 %) in aiding the diagnosis of ARMS, compared with FISH (85 and 95.8 %, respectively). All solid variant ARMS harbored FOXO1 gene rearrangements and PAX3-FOXO1 ARMS were detected to the exclusion of PAX7-FOXO1. In comparative analysis, both FISH and PCR are useful in aiding the diagnosis of ARMS and excluding its sarcomatous mimics. FISH is more reliable technically but has less specificity than PCR. In cases where ARMS is in the differential diagnosis, it is optimal to perform both PCR and FISH: both have similar sensitivities for detecting ARMS, but FISH may confirm or exclude cases that are technically unsuccessful with PCR, while PCR can detect specific fusion transcripts that may be useful prognostically.