249 resultados para age-related macular degeneration


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose:To determine the optimal role of OCT in diagnosing and monitoring nAMD (detecting disease activity and the need for further anti-VEGF treatment).
Methods:Systematic review. Major electronic databases and websites were searched. Studies were included if they reported the diagnostic performance of time domain or spectral domain OCT (or selected other tests) against a reference standard of ophthalmologist-interpreted fluorescein angiography in people with newly suspected or previously diagnosed nAMD. Risk of bias was assessed by two independent investigators using QUADAS-2. Summary receiver operating characteristic (SROC) curves were produced for each test given sufficient data.
Results:3700 titles/abstracts were screened, and 120 (3.2%) were selected for full-text assessment. A total of 22 studies were included (17 on diagnosis, 7 monitoring, and 3 both). From 15 studies reporting OCT data, sensitivity and specificity ranged from 59% to 100% and 27% to 100%, respectively.
Conclusions:The reported diagnostic performance of OCT showed large variability. The methodological quality of most studies was sub-optimal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) is the leading cause of blindness among white caucasians over the age of 50 years with a prevalence rate expected to increase markedly with an anticipated increase in the life span of the world population. To further expand our knowledge of the genetic architecture of the disease, we pursued a candidate gene approach assessing 25 genes and a total of 109 variants. Of these, synonymous single nucleotide polymorphism (SNP) rs17810398 located in death-associated protein-like 1 (DAPL1) was found to be associated with AMD in a joint analysis of 3,229 cases and 2,835 controls from five studies [combined P ADJ = 1.15 × 10(-6), OR 1.332 (1.187-1.496)]. This association was characterized by a highly significant sex difference (P diff = 0.0032) in that it was clearly confined to females with genome-wide significance [P ADJ = 2.62 × 10(-8), OR 1.541 (1.324-1.796); males: P ADJ = 0.382, OR 1.084 (0.905-1.298)]. By targeted resequencing of risk and non-risk associated haplotypes in the DAPL1 locus, we identified additional potentially functional risk variants, namely a common 897-bp deletion and a SNP predicted to affect a putative binding site of an exonic splicing enhancer. We show that the risk haplotype correlates with a reduced retinal transcript level of two, less frequent, non-canonical DAPL1 isoforms. DAPL1 plays a role in epithelial differentiation and may be involved in apoptotic processes thereby suggesting a possible novel pathway in AMSaveD pathogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The purpose of this systematic review was to identify the frequency and type of patient-reported outcome measures (PROMs) used in recent randomised controlled trials (RCTs) for age-related macular degeneration (AMD).

METHODS: The authors conducted a systematic search between January 2010 and November 2013 in MEDLINE, EMBASE, Scopus, Cochrane Library (Central) and the clinical trials registries (http://www.controlled-trials.com and http://www.ClinicalTrials.gov) according to defined inclusion criteria (RCTs on AMD in English). Two independent reviewers evaluated studies for inclusion. One reviewer extracted data of included studies, and a second masked reviewer assessed 10% to confirm accuracy in data collection. Reference lists of included papers and appendices of relevant Cochrane systematic reviews were scanned to identify other relevant RCTs. Information collected on extracted outcomes was analysed using descriptive statistics.

RESULTS: Literature and registry search yielded 3816 abstracts of journal articles and 493 records from trial registries. A total of 177 RCTs were deemed to have met inclusion criteria. Of the 858 outcomes reported, 38 outcomes were identified as PROMs (4.4%). Of the 177 RCTs examined, PROMs were used in 25 trials (14.1%). The National Eye Institute Visual Function Questionnaire-25 was the most frequently used PROM instrument (64% of RCTs with PROMs included).

CONCLUSIONS: This review highlights that a small proportion of AMD RCTs included PROMs as outcome measures and that there was a variety in the instruments used.