257 resultados para ASSEMBLY LINES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we propose a technique for dual-band Class-E power amplifier design using composite right/left-handed transmission lines, CRLH TLs. Design equations are presented and design procedures are elaborated. Because of the nonlinear phase dispersion characteristic of CRLH TLs, the single previous attempt at applying this method to dual bond Class-E amplifier design was not sufficient to simultaneously satisfy, the minimum requirement of Class-E impedances at both the fundamental and the second harmonic frequencies. This article rectifies this situation. A design example illustrating the synthesis procedure for a 0.5W-5V dual band Class-E amplifier circuit simultaneously operated at 900 MHz and 2.4 GHz is given and compared with ADS simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New fully relativistic calculations of radiative rates and electron impact excitation cross-sections for Fe XVI are used to determine theoretical emission-line ratios applicable to the 251-361 and 32-77 angstrom portions of the extreme-ultraviolet (EUV) and soft X-ray spectral regions, respectively. A comparison of the EUV results with observations from the Solar Extreme-Ultraviolet Research Telescope and Spectrograph (SERTS) reveals excellent agreement between theory and experiment. However, for emission lines in the 32-49 angstrom portion of the soft X-ray spectral region, there are large discrepancies between theory and measurement for both a solar flare spectrum obtained with the X-Ray Spectrometer/Spectrograph Telescope (XSST) and for observations of Capella from the Low- Energy Transmission Grating Spectrometer (LETGS) on the Chandra X-ray Observatory. These are probably due to blending in the solar flare and Capella data from both first-order lines and from shorter wavelength transitions detected in second and third order. By contrast, there is very good agreement between our theoretical results and the XSST and LETGS observations in the 50-77 angstrom wavelength range, contrary to previous results. In particular, there is no evidence that the Fe XVI emission from the XSST flare arises from plasma at a much higher temperature than that expected for Fe XVI in ionization equilibrium, as suggested by earlier work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fully relativistic calculations of radiative rates and electron impact excitation cross-sections for Fe X are used to derive theoretical emission-line ratios involving transitions in the 174-366 angstrom wavelength range. A comparison of these with solar active region observations obtained during the 1989 and 1995 flights of the Solar Extreme-ultraviolet Research Telescope and Spectrograph (SERTS) reveals generally very good agreement between theory and experiment. Several Fe X emission features are detected for the first time in SERTS spectra, while the 3s(2)3p(5) P-2(3/2)-3s(2)3p(4)(S-1)3d D-2(3/2) transition at 195.32 angstrom is identified for the first time (to our knowledge) in an astronomical source. The most useful Fe X electron density (N-e) diagnostic line ratios are assessed to be 175.27/174.53 and 175.27/177.24, which both involve lines close in wavelength and free from blends, vary by factors of 13 between N-e = 10(8) and 10(11) cm(-3), and yet show little temperature sensitivity. Should these lines not be available, then the 257.25/345.74 ratio may be employed to determine N-e, although this requires an accurate evaluation of the instrument intensity calibration over a relatively large wavelength range. However, if the weak 324.73 angstrom line of Fe X is reliably detected, the use of 324.73/345.74 or 257.25/324.73 is recommended over 257.25/345.74. Electron densities deduced from 175.27/174.53 and 175.27/177.24 for the stars Procyon and alpha Cen, using observations from the Extreme-Ultraviolet Explorer (EUVE) satellite, are found to be consistent and in agreement with the values of N-e determined from other diagnostic ratios in the EUVE spectra. A comparison of several theoretical extreme-ultraviolet Fe X line ratios with experimental values for a theta-pinch, for which the plasma parameters have been independently determined, reveals reasonable agreement between theory and observation, providing some independent support for the accuracy of the adopted atomic data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous reports have shown that DNA methylation profiles within primary human malignant tissues are altered when these cells are transformed into cancer cell lines. However, it is unclear if similar differences in DNA methylation profiles exist between DNA derived from peripheral blood leukocytes (PBLs) and corresponding Epstein-Barr Virus transformed lymphoblastoid cell lines (LCLs). To assess the utility of LCLs as a resource for methylation studies we have compared DNA methylation profiles in promoter and 5' regions of 318 genes in PBL and LCL sample pairs from patients with type 1 diabetes with or without nephropathy. We identified a total of 27 (similar to 8%) genes that revealed different DNA methylation profiles in PBL compared with LCL-derived DNA samples. In conclusion, although the profiles for most promoter regions were similar between PBL-LCL pairs, our results indicate that LCL-derived DNA may not be suitable for DNA methylation studies at least in diabetic nephropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel open-ended waveguide cavity resonator for the microwave curing of bumps, underfills and encapsulants is described. The open oven has the potential to provide fast alignment of devices during flip-chip assembly, direct chip attach, surface mount assembly or wafer-scale level packaging. The prototype microwave oven was designed to operate at X-band for ease of testing, although a higher frequency version is planned. The device described in the paper takes the form of a waveguide cavity resonator. It is approximately square in cross-section and is filled with a low-loss dielectric with a relative permittivity of 6. It is excited by end-fed probes in order to couple power preferentially into the TM3,3,k mode with the object of forming nine 'hot-spots' in the open end. Low power tests using heat sensitive film demonstrate clearly that selective heating in multiple locations in the open end of the oven is achievable.