55 resultados para Mass spectrometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Time of flight (ToF) mass spectrometer suitable in terms of sensitivity, detector response and time resolution, for application in fast transient Temporal Analysis of Products (TAP) kinetic catalyst characterization is reported. Technical difficulties associated with such application as well as the solutions implemented in terms of adaptations of the ToF apparatus are discussed. The performance of the ToF was validated and the full linearity of the specific detector over the full dynamic range was explored in order to ensure its applicability for the TAP application. The reported TAP-ToF setup is the first system that achieves the high level of sensitivity allowing monitoring of the full 0-200 AMU range simultaneously with sub-millisecond time resolution. In this new setup, the high sensitivity allows the use of low intensity pulses ensuring that transport through the reactor occurs in the Knudsen diffusion regime and that the data can, therefore, be fully analysed using the reported theoretical TAP models and data processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential use of negative electrospray ionisation mass spectrometry (ESI-MS) in the characterisation of the three polyacetylenes common in carrots (Daucus carota) has been assessed. The MS scans have demonstrated that the polyacetylenes undergo a modest degree of in-source decomposition in the negative ionisation mode while the positive ionisation mode has shown predominantly sodiated ions and no [M+H](+) ions. Tandem mass spectrometric (MS/MS) studies have shown that the polyacetylenes follow two distinct fragmentation pathways: one that involves cleavage of the C3-C4 bond and the other with cleavage of the C7-C8 bond. The cleavage of the C7-C8 bond generated product ions m/z 105.0 for falcarinol, m/z 105/107.0 for falcarindiol, m/z 147.0/149.1 for falcarindiol-3-acetate. In addition to these product ions, the transitions m/z 243.2 -> 187.1 (falcarinol), m/z 259.2 -> 203.1 (falcarindiol), m/z 301.2 -> 255.2/203.1 (falcarindiol-3-acetate), mostly from the C3-C4 bond cleavage, can form the basis of multiple reaction monitoring (MRM)-quantitative methods which are poorly represented in the literature. The 'MS3' experimental data confirmed a less pronounced homolytic cleavage site between the C11-C12 bond in the falcarinol-type polacetylenes. The optimised liquid chromatography (LC)/MS conditions have achieved a baseline chromatographic separation of the three polyacetylenes investigated within 40 min total run-time. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within the framework of a European Union (EU) research project entitled

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, new method permitting the simultaneous determination and confirmation of trace residues of 24 different growth promoters and metabolites using liquid chromatography-mass spectrometry was developed and validated. The compounds were extracted from bovine tissue using acetonitrile; sodium sulphate was also added at this stage to aid with purification. The resulting mixture was then evaporated to approximately 1 ml and subsequently centrifuged at high speed and an aliquot injected onto the LC-MS/MS system. The calculated CC values ranged between 0.11 and 0.46 mu g kg-1; calculated CC were in the range 0.19-0.79 mu g kg-1. Accuracy, measurement of uncertainty, repeatability and linearity were also determined for each analyte. The analytical method was applied to a number of bovine tissue samples imported into Ireland from third countries. Levels of progesterone were found in a number of samples at concentrations ranging between 0.28 and 30.30 mu g kg-1. Levels of alpha- and beta-testosterone were also found in a number of samples at concentrations ranging between 0.22 and 8.63 mu g kg-1 and between 0.16 and 2.08 mu g kg-1 respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mass spectrometry (MS)-based metabolomics is emerging as an important field of research in many scientific areas, including chemical safety of food. A particular strength of this approach is its potential to reveal some physiological effects induced by complex mixtures of chemicals present at trace concentrations. The limitations of other analytical approaches currently employed to detect low-dose and mixture effects of chemicals make detection very problematic. Besides this basic technical challenge, numerous analytical choices have to be made at each step of a metabolomics study, and each step can have a direct impact on the final results obtained and their interpretation (i.e. sample preparation, sample introduction, ionization, signal acquisition, data processing, and data analysis). As the application of metabolomics to chemical analysis of food is still in its infancy, no consensus has yet been reached on defining many of these important parameters. In this context, the aim of the present study is to review all these aspects of MS-based approaches to metabolomics, and to give a comprehensive, critical overview of the current state of the art, possible pitfalls, and future challenges and trends linked to this emerging field. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An LC/MS/MS method was developed and validated for the simultaneous identification, confirmation, and quantification of 12 glucocorticoids in bovine milk. The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC. The developed method can detect and confirm the presence of dexamethasone, betamethasone, prednisolone, flumethasone, 6 alpha-methylprednisolone, fluorometholone, triamcinolone acetonide, prednisone, cortisone, hydrocortisone, clobetasol propionate, and clobetasol butyrate in bovine milk. Milk samples are extracted with acetonitrile; sodium chloride is subsequently added to aid partition of the milk and acetonitrile mixture. The acetonitrile extract is then subjected to liquid-liquid purification by the addition of hexane. The purified extract is evaporated to dryness and reconstituted in a water acetonitrile mixture, and determination is carried out by LC/MS/MS. The method permits analysis of up to 30 samples in 1 day.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous identification, confirmation and quantitation of seven licensed anti-inflammatory drugs (AIDS) in bovine milk. The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC. Two classes of AIDS were investigated, corticosteroids and non-steroidal anti-inflammatory drugs (NSAIDs). The developed method is capable of detecting and confirming dexamethasone (DXM), betamethasone (BTM), prednisolone (FRED), tolfenamic acid (TV), 5-hydroxy flunixin (5-OH-FLU). meloxicam (MLX) and 4-methyl amino antipyrine (4-MAA) at their associated maximum residue limits (MRLs). These compounds represent all the corticosteroids and NSAIDs licensed for use in bovine animals producing milk for human consumption. These compounds have never been analysed before in the same method and also 4-methyl amino antipyrine has never been analysed with the other licensed NSAIDs. The method can be considered rapid as permits the analysis of up to 30 samples in one day. Milk samples are extracted with acetonitrile; sodium chloride is added to aid partition of the milk and acetonitrile mixture. The acetonitrile extract is then subjected to liquid-liquid purification by the addition of hexane. The purified extract is finally evaporated to dryness and reconstituted in a water/acetonitrile mixture and determination is carried out by LC-MS/MS. Decision limit (CC alpha) values and detection capability (CC beta) values have been established for each compound. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A confirmatory method has been developed and validated that allows for the simultaneous detection of medroxyprogesterone acetate (MPA), megestrol acetate (MGA), melengestrol acetate (MLA), chlormadinone acetate (CMA) and delmadinone acetate (DMA) in animal kidney fat using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The compounds were extracted from kidney fat using acetonitrile, defatted using a hexane wash and subsequent saponification. Extracts were then purified on Isolute CN solid-phase extraction cartridges and analysed by LC-MS/MS. The method was validated in animal kidney fat in accordance with the criteria defined in Commission Decision 2002/657/EC. The decision limit (CC) was calculated to be 0.12, 0.48, 0.40, 0.63 and 0.54 g kg-1, respectively, for MPA, MGA, MLA, DMA and CMA, with respective detection capability (CC) values of 0.20, 0.81, 0.68, 1.07 and 0.92 g kg-1. The measurement uncertainty of the method was estimated at 16, 16, 19, 27 and 26% for MPA, MGA, MLA, DMA and CMA, respectively. Fortifying kidney fat samples (n = 18) in three separate assays showed the accuracy of the method to be between 98 and 100%. The precision of the method, expressed as % RSD, for within-laboratory reproducibility at three levels of fortification (1, 1.5 and 2 g kg-1 for MPA, 5, 7.5 and 10 g kg-1 for MGA, MLA, DMA and CMA) was less than 5% for all analytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is described for the quantitative confirmation of halofuginone (HFG) residues in chicken liver and eggs. This method is based on LC coupled to positive ion electrospray MS-MS of the tissue extracts, prepared by trypsin digestion of the tissues followed by liquid-liquid extraction and final clean-up using Solid Phase Extraction (SPE). The [M+H](+) ion at m/z 416 is monitored along with four transitions at m/z 398, 138, 120 and 100. The method has been validated according to the draft EU criteria for the analysis of veterinary drug residues at 15, 30 and 45 mug kg (-1) in liver and 5, 15 and 50 mug kg (-1) in eggs. The new analytical limits, CCalpha and CCbeta were calculated for liver and were 35.4 and 43.6 mug kg (-1), respectively. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gas chromatographic/mass spectrometric method is described for the detection of clenbuterol residues in liver, muscle, urine and retina. Tissue samples are first digested using protease and any clenbuterol present is extracted using a simple liquid/liquid extraction procedure. The dried extracts are then derivatized using methylboronic acid and the derivatives are subjected to gas chromatography/mass spectrometry on a magnetic sector instrument. The detection limit of the assay is 0.05 ng g-1 clenbuterol in liver, muscle or urine using a 10 g sample size, and 4 ng g-1 in retina using a 0.5 g sample size. The assay is made very specific by using selected ion monitoring of three ions at a resolution of 3500 and by ion ratio measurements. The precision and reproducibility of the assay are enhanced by the use of a deuterated internal standard, with a typical coefficient of variation of 3%.