185 resultados para DOSE REQUIREMENTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the clinical implications of a variable relative biological effectiveness (RBE) on proton dose fractionation. Using acute exposures, the current clinical adoption of a generic, constant cell killing RBE has been shown to underestimate the effect of the sharp increase in linear energy transfer (LET) in the distal regions of the spread-out Bragg peak (SOBP). However, experimental data for the impact of dose fractionation in such scenarios are still limited.

Methods and Materials: Human fibroblasts (AG01522) at 4 key depth positions on a clinical SOBP of maximum energy 219.65 MeV were subjected to various fractionation regimens with an interfraction period of 24 hours at Proton Therapy Center in Prague, Czech Republic. Cell killing RBE variations were measured using standard clonogenic assays and were further validated using Monte Carlo simulations and parameterized using a linear quadratic formalism.

Results: Significant variations in the cell killing RBE for fractionated exposures along the proton dose profile were observed. RBE increased sharply toward the distal position, corresponding to a reduction in cell sparing effectiveness of fractionated proton exposures at higher LET. The effect was more pronounced at smaller doses per fraction. Experimental survival fractions were adequately predicted using a linear quadratic formalism assuming full repair between fractions. Data were also used to validate a parameterized variable RBE model based on linear α parameter response with LET that showed considerable deviations from clinically predicted isoeffective fractionation regimens.

Conclusions: The RBE-weighted absorbed dose calculated using the clinically adopted generic RBE of 1.1 significantly underestimates the biological effective dose from variable RBE, particularly in fractionation regimens with low doses per fraction. Coupled with an increase in effective range in fractionated exposures, our study provides an RBE dataset that can be used by the modeling community for the optimization of fractionated proton therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Individuals who began taking low-dose aspirin before they were diagnosed with colorectal cancer were reported to have longer survival times than patients who did not take this drug. We investigated survival times of patients who begin taking low-dose aspirin after a diagnosis of colorectal cancer in a large population-based cohort study.

METHODS: We performed a nested case-control analysis using a cohort of 4794 patients diagnosed with colorectal cancer from 1998 through 2007, identified from the UK Clinical Practice Research Datalink and confirmed by cancer registries. There were 1559 colorectal cancer-specific deaths, recorded by the Office of National Statistics; these were each matched with up to 5 risk-set controls. Conditional logistic regression was used to calculate odds ratios (OR) and 95% confidence intervals (CI), based on practitioner-recorded aspirin usage.

RESULTS: Overall, low-dose aspirin use after a diagnosis of colorectal cancer was not associated with colorectal cancer-specific mortality (adjusted OR = 1.06; 95% CI: 0.92-1.24) or all-cause mortality (adjusted OR = 1.06; 95% CI: 0.94-1.19). A dose-response association was not apparent; for example, low-dose aspirin use for more than 1 year after diagnosis was not associated with colorectal cancer-specific mortality (adjusted OR = 0.98; 95% CI: 0.82-1.19). There was also no association between low-dose aspirin usage and colon cancer-specific mortality (adjusted OR = 1.02; 95% CI: 0.83-1.25) or rectal cancer-specific mortality (adjusted OR = 1.10; 95% CI: 0.88-1.38).

CONCLUSIONS: In a large population-based cohort, low-dose aspirin usage after diagnosis of colorectal cancer did not increase survival time.