OBJECTIVES: To develop a sleep hypoxia (SH) in emphysema (SHE) rat model and to explore whether SHE results in more severe hepatic inflammation than emphysema alone and whether the inflammation changes levels of coagulant/anticoagulant factors synthesized in the liver. METHODS: Seventy-five rats were put into 5 groups: SH control (SHCtrl), treated with sham smoke exposure (16 weeks) and SH exposure (12.5% O(2), 3 h/d, latter 8 weeks); emphysema control (ECtrl), smoke exposure and sham SH exposure (21% O(2)); short SHE (SHEShort), smoke exposure and short SH exposure (1.5 h/d); mild SHE (SHEMild), smoke exposure and mild SH exposure (15% O(2)); standard SHE (SHEStand), smoke exposure and SH exposure. Therefore, ECtrl, SHEShort, SHEMild and SHEStand group were among emphysematous groups. Arterial blood gas (ABG) data was obtained during preliminary tests. After exposure, hepatic inflammation (interleukin -6 [IL-6] mRNA and protein, tumor necrosis factor α [TNFα] mRNA and protein) and liver coagulant/anticoagulant factors (antithrombin [AT], fibrinogen [FIB] and Factor VIII [F VIII]) were evaluated. SPSS 11.5 software was used for statistical analysis. RESULTS: Characteristics of emphysema were obvious in emphysematous groups and ABGs reached SH criteria on hypoxia exposure. Hepatic inflammation parameters and coagulant factors are the lowest in SHCtrl and the highest in SHEStand while AT is the highest in SHCtrl and the lowest in SHEStand. Inflammatory cytokines of liver correlate well with coagulant factors positively and with AT negatively. CONCLUSIONS: When SH is combined with emphysema, hepatic inflammation and coagulability enhance each other synergistically and produce a more significant liver-derivative inflammatory and prothrombotic status.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device. We found the best hemoglobin correlations were when ratios at isosbestic points of oxy- and deoxyhemoglobin were used, specifically 529/500 nm. Baseline subtraction improved correlations, specifically at 520/509 nm. These results demonstrate proof-of-concept for the ability of this noninvasive device to monitor hemoglobin concentration changes due to surgical blood loss. The 529/500 nm ratio also appears to account for variations in probe pressure, as determined from measurements on two volunteers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The myokine irisin is supposed to be cleaved from a transmembrane precursor, FNDC5 (fibronectin type III domain containing 5), and to mediate beneficial effects of exercise on human metabolism. However, evidence for irisin circulating in blood is largely based on commercial ELISA kits which are based on polyclonal antibodies (pAbs) not previously tested for cross-reacting serum proteins. We have analyzed four commercial pAbs by Western blotting, which revealed prominent cross-reactivity with non-specific proteins in human and animal sera. Using recombinant glycosylated and non-glycosylated irisin as positive controls, we found no immune-reactive bands of the expected size in any biological samples. A FNDC5 signature was identified at ~20 kDa by mass spectrometry in human serum but was not detected by the commercial pAbs tested. Our results call into question all previous data obtained with commercial ELISA kits for irisin, and provide evidence against a physiological role for irisin in humans and other species.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

© 2016 International Journal of the Economics of Business.Human blood plasma and its derivative therapies have been used therapeutically for more than 50 years, after first being widely used to treat injuries during World War II. In certain countries, manufacturers of these therapies – known as plasma-derived medicinal products (PDMPs) – compensate plasma donors, raising healthcare and ethical concerns among some parties. In particular, the World Health Organization has taken a strong advocacy position that compensation for blood donations should be eliminated worldwide. This review evaluates the key economic factors underlying the supply and demand for PDMPs and the evidence pointing to the policy options that are most likely to maintain a reliable supply of life-sustaining therapies. It concludes that compensated plasma donation is important for maintaining adequate and consistent supplies of plasma and limits the risk of under-treatment for the foreseeable future.