4 resultados para Microfluidics

em DRUM (Digital Repository at the University of Maryland)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manipulation of single cells and particles is important to biology and nanotechnology. Our electrokinetic (EK) tweezers manipulate objects in simple microfluidic devices using gentle fluid and electric forces under vision-based feedback control. In this dissertation, I detail a user-friendly implementation of EK tweezers that allows users to select, position, and assemble cells and nanoparticles. This EK system was used to measure attachment forces between living breast cancer cells, trap single quantum dots with 45 nm accuracy, build nanophotonic circuits, and scan optical properties of nanowires. With a novel multi-layer microfluidic device, EK was also used to guide single microspheres along complex 3D trajectories. The schemes, software, and methods developed here can be used in many settings to precisely manipulate most visible objects, assemble objects into useful structures, and improve the function of lab-on-a-chip microfluidic systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid, sensitive and selective detection of chemical hazards and biological pathogens has shown growing importance in the fields of homeland security, public safety and personal health. In the past two decades, efforts have been focusing on performing point-of-care chemical and biological detections using miniaturized biosensors. These sensors convert target molecule binding events into measurable electrical signals for quantifying target molecule concentration. However, the low receptor density and the use of complex surface chemistry in receptors immobilization on transducers are common bottlenecks in the current biosensor development, adding to the cost, complexity and time. This dissertation presents the development of selective macromolecular Tobacco mosaic virus-like particle (TMV VLP) biosensing receptor, and the microsystem integration of VLPs in microfabricated electrochemical biosensors for rapid and performance-enhanced chemical and biological sensing. Two constructs of VLPs carrying different receptor peptides targeting at 2,4,6-trinitrotoluene (TNT) explosive or anti-FLAG antibody are successfully bioengineered. The VLP-based TNT electrochemical sensor utilizes unique diffusion modulation method enabled by biological binding between target TNT and receptor VLP. The method avoids the influence from any interfering species and environmental background signals, making it extremely suitable for directly quantifying the TNT level in a sample. It is also a rapid method that does not need any sensor surface functionalization process. For antibody sensing, the VLPs carrying both antibody binding peptides and cysteine residues are assembled onto the gold electrodes of an impedance microsensor. With two-phase immunoassays, the VLP-based impedance sensor is able to quantify antibody concentrations down to 9.1 ng/mL. A capillary microfluidics and impedance sensor integrated microsystem is developed to further accelerate the process of VLP assembly on sensors and improve the sensitivity. Open channel capillary micropumps and stop-valves facilitate localized and evaporation-assisted VLP assembly on sensor electrodes within 6 minutes. The VLP-functionalized impedance sensor is capable of label-free sensing of antibodies with the detection limit of 8.8 ng/mL within 5 minutes after sensor functionalization, demonstrating great potential of VLP-based sensors for rapid and on-demand chemical and biological sensing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microfluidic technologies have great potential to help create automated, cost-effective, portable devices for rapid point of care (POC) diagnostics in diverse patient settings. Unfortunately commercialization is currently constrained by the materials, reagents, and instrumentation required and detection element performance. While most microfluidic studies utilize planar detection elements, this dissertation demonstrates the utility of porous volumetric detection elements to improve detection sensitivity and reduce assay times. Impedemetric immunoassays were performed utilizing silver enhanced gold nanoparticle immunoconjugates (AuIgGs) and porous polymer monolith or silica bead bed detection elements within a thermoplastic microchannel. For a direct assay with 10 µm spaced electrodes the detection limit was 0.13 fM AuIgG with a 3 log dynamic range. The same assay was performed with electrode spacing of 15, 40, and 100 µm with no significant difference between configurations. For a sandwich assay the detection limit was10 ng/mL with a 4 log dynamic range. While most impedemetric assays rely on expensive high resolution electrodes to enhance planar senor performance, this study demonstrates the employment of porous volumetric detection elements to achieve similar performance using lower resolution electrodes and shorter incubation times. Optical immunoassays were performed using porous volumetric capture elements perfused with refractive index matching solutions to limit light scattering and enhance signal. First, fluorescence signal enhancement was demonstrated with a porous polymer monolith within a silica capillary. Next, transmission enhancement of a direct assay was demonstrated by infusing aqueous sucrose solutions through silica bead beds with captured silver enhanced AuIgGs yielding a detection limit of 0.1 ng/mL and a 5 log dynamic range. Finally, ex situ functionalized porous silica monolith segments were integrated into thermoplastic channels for a reflectance based sandwich assay yielding a detection limit of 1 ng/mL and a 5 log dynamic range. The simple techniques for optical signal enhancement and ex situ element integration enable development of sensitive, multiplexed microfluidic sensors. Collectively the demonstrated experiments validate the use of porous volumetric detection elements to enhance impedemetric and optical microfluidic assays. The techniques rely on commercial reagents, materials compatible with manufacturing, and measurement instrumentation adaptable to POC diagnostics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been considerable interest in developing shape-changing soft materials for potential applications in drug delivery, microfluidics and biosensing. These shape- changing materials are inspired by the morphological changes exhibited by plants in nature, such as the Venus flytrap. One specific class of shape-change is that from a flat sheet to a folded structure (e.g., a tube). Such “self-folding” materials are usually composed of polymer hydrogels, and these typically fold in response to external stimuli such as pH and temperature. In order to develop these hydrogels for the previously described applications, it is necessary to expand the range of triggers. The focus of this dissertation is the advancement of shape-changing polymer hydrogels that are sensitive to uncommon cues such as specific biomolecules (enzymes), the substrates for such enzymes, or specific multivalent cations. First, we describe a hybrid gel that responds to the presence of low concentrations of a class of enzymes known as matrix metalloproteinases (MMPs). The hybrid gel was created by utilizing photolithographic techniques to combine two or more gels with distinct chemical composition into the same material. Certain portions of the hybrid gel are composed of a biopolymer derivative with crosslinkable groups. The hybrid gel is flat in water; however, in the presence of MMPs, the regions containing the biopolymer are degraded and the flat sheet folds to form a 3D structure. We demonstrate that hydrogels with different patterns can transform into different 3D structures such as tubes, helices and pancakes. Furthermore, this shape change can be made to occur at physiological concentrations of enzymes. Next, we report a gel with two layers that undergoes a shape change in the presence of glucose. The enzyme glucose oxidase (GOx) is immobilized in one of the layers. GOx catalyzes the conversion of glucose to gluconic acid. The production of gluconic acid decreases the local pH. The decrease in local pH causes one of the layers to swell. As a result, the flat sheet folds to form a tube. The tube unfolds to form a flat sheet when it is transferred to a solution with no glucose present. Therefore, this biomolecule- triggered shape transformation is reversible, meaning the glucose sensing gel is reusable. Furthermore, this shape change only occurs in the presence of glucose and it does not occur in the presence of other small sugars such as fructose. In our final study, we report the shape change of a gel with two layers in the presence of multivalent ions such as Ca2+ and Sr2+. The gel consists of a passive layer and an active layer. The passive layer is composed of dimethylyacrylamide (DMAA), which does not interact with multivalent ions. The active layer consists of DMAA and the biopolymer alginate. In the presence of Ca2+ ions, the alginate chains crosslink and the active layer shrinks. As a result, the gel converts from a flat sheet to a folded tube. What is particularly unusual is the direction of folding. In most cases, when flat rectangular gels fold, they do so about their short-side. However, our gels typically fold about their long-side. We hypothesize that non-homogeneous swelling determines the folding axis.