16 resultados para distributed system

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the early 20th century, many researchers have attempted to determine how fungi are able to emit light. The first successful experiment was obtained using the classical luciferin-luciferase test that consists of mixing under controlled conditions hot (substrate/luciferin) and cold (enzyme/luciferase) water extracts prepared from bioluminescent fungi. Failures by other researchers to reproduce those experiments using different species of fungi lead to the hypothesis of a non-enzymatic luminescent pathway. Only recently, the involvement of a luciferase in this system was proven, thus confirming its enzymatic nature. Of the 100 000 described species in Kingdom Fungi, only 71 species are known to be luminescent and they are distributed unevenly amongst four distantly related lineages. The question we address is whether the mechanism of bioluminescence is the same in all four evolutionary lineages suggesting a single origin of luminescence in the Fungi, or whether each lineage has a unique mechanism for light emission implying independent origins. We prepared hot and cold extracts of numerous species representing the four bioluminescent fungal lineages and performed cross-reactions (luciferin x luciferase) in all possible combinations using closely related non-luminescent species as controls. All cross-reactions with extracts from luminescent species yielded positive results, independent of lineage, whereas no light was emitted in cross-reactions with extracts from non-luminescent species. These results support the hypothesis that all four lineages of luminescent fungi share the same type of luciferin and luciferase, that there is a single luminescent mechanism in the Fungi, and that fungal luciferin is not a ubiquitous molecule in fungal metabolism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The installation of induction distributed generators should be preceded by a careful study in order to determine if the point of common coupling is suitable for transmission of the generated power, keeping acceptable power quality and system stability. In this sense, this paper presents a simple analytical formulation that allows a fast and comprehensive evaluation of the maximum power delivered by the induction generator, without losing voltage stability. Moreover, this formulation can be used to identify voltage stability issues that limit the generator output power. All the formulation is developed by using the equivalent circuit of squirrel-cage induction machine. Simulation results are used to validate the method, which enables the approach to be used as a guide to reduce the simulation efforts necessary to assess the maximum output power and voltage stability of induction generators. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Failure detection is at the core of most fault tolerance strategies, but it often depends on reliable communication. We present new algorithms for failure detectors which are appropriate as components of a fault tolerance system that can be deployed in situations of adverse network conditions (such as loosely connected and administered computing grids). It packs redundancy into heartbeat messages, thereby improving on the robustness of the traditional protocols. Results from experimental tests conducted in a simulated environment with adverse network conditions show significant improvement over existing solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current scientific applications have been producing large amounts of data. The processing, handling and analysis of such data require large-scale computing infrastructures such as clusters and grids. In this area, studies aim at improving the performance of data-intensive applications by optimizing data accesses. In order to achieve this goal, distributed storage systems have been considering techniques of data replication, migration, distribution, and access parallelism. However, the main drawback of those studies is that they do not take into account application behavior to perform data access optimization. This limitation motivated this paper which applies strategies to support the online prediction of application behavior in order to optimize data access operations on distributed systems, without requiring any information on past executions. In order to accomplish such a goal, this approach organizes application behaviors as time series and, then, analyzes and classifies those series according to their properties. By knowing properties, the approach selects modeling techniques to represent series and perform predictions, which are, later on, used to optimize data access operations. This new approach was implemented and evaluated using the OptorSim simulator, sponsored by the LHC-CERN project and widely employed by the scientific community. Experiments confirm this new approach reduces application execution time in about 50 percent, specially when handling large amounts of data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synchronous distributed generators are prone to operate islanded after contingencies, which is usually not allowed due to safety and power-quality issues. Thus, there are several anti-islanding techniques; however, most of them present technical limitations so that they are likely to fail in certain situations. Therefore, it is important to quantify and determine whether the scheme under study is adequate or not. In this context, this paper proposes an index to evaluate the effectiveness of anti-islanding frequency-based relays commonly used to protect synchronous distributed generators. The method is based on the calculation of a numerical index that indicates the time period that the system is unprotected against islanding considering the global period of analysis. Although this index can precisely be calculated based on several electromagnetic transient simulations, a practical method is also proposed to calculate it directly from simple analytical formulas or lookup tables. The results have shown that the proposed approach can assist distribution engineers to assess and set anti-islanding protection schemes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Purified water for pharmaceutical purposes must be free of microbial contamination and pyrogens. Even with the additional sanitary and disinfecting treatments applied to the system (sequential operational stages), Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were isolated and identified from a thirteen-stage purification system. To evaluate the efficacy of the chemical agents used in the disinfecting process along with those used to adjust chemical characteristics of the system, over the identified bacteria, the kinetic parameter of killing time (D-value) necessary to inactivate 90% of the initial bioburden (decimal reduction time) was experimentally determined. Methods Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were called in house (wild) bacteria. Pseudomonas diminuta ATCC 11568, Pseudomonas alcaligenes INCQS , Pseudomonas aeruginosa ATCC 15442, Pseudomonas fluorescens ATCC 3178, Pseudomonas picketti ATCC 5031, Bacillus subtilis ATCC 937 and Escherichia coli ATCC 25922 were used as 'standard' bacteria to evaluate resistance at 25°C against either 0.5% citric acid, 0.5% hydrochloric acid, 70% ethanol, 0.5% sodium bisulfite, 0.4% sodium hydroxide, 0.5% sodium hypochlorite, or a mixture of 2.2% hydrogen peroxide (H2O2) and 0.45% peracetic acid. Results The efficacy of the sanitizers varied with concentration and contact time to reduce decimal logarithmic (log10) population (n cycles). To kill 90% of the initial population (or one log10 cycle), the necessary time (D-value) was for P. aeruginosa into: (i) 0.5% citric acid, D = 3.8 min; (ii) 0.5% hydrochloric acid, D = 6.9 min; (iii) 70% ethanol, D = 9.7 min; (iv) 0.5% sodium bisulfite, D = 5.3 min; (v) 0.4% sodium hydroxide, D = 14.2 min; (vi) 0.5% sodium hypochlorite, D = 7.9 min; (vii) mixture of hydrogen peroxide (2.2%) plus peracetic acid (0.45%), D = 5.5 min. Conclusion The contact time of 180 min of the system with the mixture of H2O2+ peracetic acid, a total theoretical reduction of 6 log10 cycles was attained in the water purified storage tank and distribution loop. The contact time between the water purification system (WPS) and the sanitary agents should be reviewed to reach sufficient bioburden reduction (over 6 log10).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background The public health system of Brazil is structured by a network of increasing complexity, but the low resolution of emergency care at pre-hospital units and the lack of organization of patient flow overloaded the hospitals, mainly the ones of higher complexity. The knowledge of this phenomenon induced Ribeirão Preto to implement the Medical Regulation Office and the Mobile Emergency Attendance System. The objective of this study was to analyze the impact of these services on the gravity profile of non-traumatic afflictions in a University Hospital. Methods The study conducted a retrospective analysis of the medical records of 906 patients older than 13 years of age who entered the Emergency Care Unit of the Hospital of the University of São Paulo School of Medicine at Ribeirão Preto. All presented acute non-traumatic afflictions and were admitted to the Internal Medicine, Surgery or Neurology Departments during two study periods: May 1996 (prior to) and May 2001 (after the implementation of the Medical Regulation Office and Mobile Emergency Attendance System). Demographics and mortality risk levels calculated by Acute Physiology and Chronic Health Evaluation II (APACHE II) were determined. Results From 1996 to 2001, the mean age increased from 49 ± 0.9 to 52 ± 0.9 (P = 0.021), as did the percentage of co-morbidities, from 66.6 to 77.0 (P = 0.0001), the number of in-hospital complications from 260 to 284 (P = 0.0001), the mean calculated APACHE II mortality risk increased from 12.0 ± 0.5 to 14.8 ± 0.6 (P = 0.0008) and mortality rate from 6.1 to 12.2 (P = 0.002). The differences were more significant for patients admitted to the Internal Medicine Department. Conclusion The implementation of the Medical Regulation and Mobile Emergency Attendance System contributed to directing patients with higher gravity scores to the Emergency Care Unit, demonstrating the potential of these services for hierarchical structuring of pre-hospital networks and referrals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. Methods The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Results Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). Conclusions An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Public health strategies to reduce cardiovascular morbidity and mortality should focus on global cardiometabolic risk reduction. The efficacy of lifestyle changes to prevent type 2 diabetes have been demonstrated, but low-cost interventions to reduce cardiometabolic risk in Latin-America have been rarely reported. Our group developed 2 programs to promote health of high-risk individuals attending a primary care center in Brazil. This study compared the effects of two 9-month lifestyle interventions, one based on medical consultations (traditional) and another with 13 multi-professional group sessions in addition to the medical consultations (intensive) on cardiometabolic parameters. Adults were eligible if they had pre-diabetes (according to the American Diabetes Association) and/or metabolic syndrome (International Diabetes Federation criteria for Latin-America). Data were expressed as means and standard deviations or percentages and compared between groups or testing visits. A p-value < 0.05 was considered significant. Results: 180 individuals agreed to participate (35.0% men, mean age 54.7 ± 12.3 years, 86.1% overweight or obese). 83 were allocated to the traditional and 97 to the intensive program. Both interventions reduced body mass index, waist circumference and tumor necrosis factor-α. Only intensive program reduced 2-hour plasma glucose and blood pressure and increased adiponectin values, but HDL-cholesterol increased only in the traditional. Also, responses to programs were better in intensive compared to traditional program in terms of blood pressure and adiponectin improvements. No new case of diabetes in intensive but 3 cases and one myocardial infarction in traditional program were detected. Both programs induced metabolic improvement in the short-term, but if better results in the intensive are due to higher awareness about risk and self-motivation deserves further investigation. In conclusion, these low-cost interventions are able to minimize cardiometabolic risk factors involved in the progression to type 2 diabetes and/or cardiovascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Introduction Pelvicalyceal cysts are common findings in autopsies and can manifest with a variety of patterns. These cystic lesions are usually a benign entity with no clinical significance unless they enlarge enough to cause compression of the adjacent collecting system and consequently obstructive uropathy. Few cases of the spontaneous rupture of pelvicalyceal renal cysts have been published and to the best of our knowledge there is no report of a combined rupture to collector system and retroperitoneal space documented during a multiphase computed tomography. Case presentation We report a case of a ‘real-time’ spontaneous rupture of a pelvicalyceal cyst into the collecting system with fistulization into the retroperitoneum. The patient was a 78-year-old Caucasian man with a previous history of renal stones and a large pelvicalyceal renal cyst who was admitted to our Emergency department with acute right flank pain. A multiphase computed tomography was performed and the pre-contrast images demonstrated a right pelvicalyceal renal cyst measuring 12.0 × 6.1cm in the lower pole causing moderate dilation of the upper right renal collection system. In addition, a partially obstructive stone on the left distal ureter with mild left hydronephrosis was noted. The nephrographic phase did not add any new information. The excretory phase (10-minute delay) demonstrated a spontaneous rupture of the cyst into the pelvicalyceal system with posterior fistulization into the retroperitoneal space. Conclusion In this case study we present time-related changes of a rare pelvicalyceal cyst complication, which to the best of our knowledge has fortunately not been previously documented. Analysis of the sequential images and comparison with an earlier scan allowed us to better understand the physiopathological process of the rupture, the clinical presentation and to elaborate hypotheses for its etiopathogenesis.