17 resultados para Ultrasound

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to establish longitudinal reference ranges for fetal ultrasound biometry measurements and growth parameters in twin pregnancies. METHOD: A total of 200 uncomplicated twin pregnancies before 21 weeks of gestation were recruited for this prospective, longitudinal study. Women who abandoned follow-up, pregnancies with unknown outcomes or pregnancies with complications were excluded. Ultrasound scans were performed every three weeks, and biparietal and occipitofrontal diameters, head and abdominal circumferences, and femur diaphysis length measurements were obtained for each fetus at each visit. Estimated fetal weight, biparietal/occipitofrontal diameter, head circumference/abdominal circumference, and femur diaphysis length/abdominal circumference ratios were also calculated. Multilevel regression analysis was performed on normalized data. RESULTS: A total of 807 ultrasound examinations were performed in 125 twin pregnancies between 14 and 38 weeks of gestation (6.5 +/- 1.4 scans/pregnancy). Regression analysis demonstrated significant correlations for all variables with gestational age, namely log of the biparietal diameter (r = 0.98), log of the occipitofrontal diameter (r = 0.98), log of the head circumference (r = 0.99), log of the abdominal circumference (r = 0.98), square root of the femur length (r = 0.99), log of the estimated fetal weight (r = 0.99), biparietal/occipitofrontal ratio (r = -0.11), head/abdomen circumference ratio (r = -0.56), and log of the femur length/abdominal circumference ratio (r = 0.61). Values corresponding to the 10th, 50th, and 90th percentiles for estimated fetal weight at 28, 32, and 36 weeks, respectively, were as follows: 937, 1,096, 1,284 g; 1,462, 1,720, 2,025 g; and 2,020, 2,399, 2,849 g. CONCLUSION: In twin pregnancies, fetal ultrasound biometry measurements and growth parameters show a significant correlation with gestational age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the important role of leptin in metabolism, we looked for a possible association of leptin and leptin receptor polymorphisms with carcass and growth traits in Nellore cattle. We examined associations of leptin and leptin receptor SNPs with ultrasound carcass (longissimus dorsi muscle area (ribeye area), backfat thickness and rump fat thickness and growth traits (weaning weight adjusted to 210 days of age, yearling weight adjusted to 550 days of age, weight gain of weaning to yearling and scrotal circumference adjusted to 550 days of age) of 2162 Bos primigenius indicus (Nellore) animals. Allele and genotypic frequencies were calculated for each marker. Allele substitution, additive and dominance effects of the polymorphisms were also evaluated. Some alleles of the molecular markers had low frequencies, lower than 1%, in the sample analyzed, although the same polymorphisms described for B. p. taurus cattle were found. Due to very low allelic frequencies, the E2JW, A59V and UASMS2 markers were not included in the analysis, because they were almost fixed. E2FB was found to be significantly associated with weight gain, ribeye area and backfat thickness. The promoter region markers, C963T and UASMS1, were also found to be significantly associated with ribeye area. T945M was significantly associated with weight gain. We conclude that the leptin and receptor gene markers would be useful for marker-assisted selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the diagnostic quality of first-trimester ultrasound images transmitted in realtime using low-cost telecommunications. A prospective sample of fetal ultrasound images from 11 weeks to 13 weeks and six days of pregnancy was obtained from pregnant women over 18 years old. The examinations were transmitted in realtime to three independent examiners who carried out a qualitative assessment based on parameters established by the Fetal Medicine Foundation. All fetal structures could be viewed and the quality of images received by the examiners was considered normal. There were significant differences for crown-rump length and nuchal translucency in the transmitted images but the loss in definition was acceptable. Thus the quality of images transmitted via the Internet through the use of low-cost software appeared suitable for screening for chromosomal abnormalities in the first trimester of pregnancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to develop equations to predict retail product and fat trim (weights and percentages) for Nellore (Bos indicus) cattle. Live ultrasound measurements of the longissimus muscle area, backfat thickness at the 12th rib and rump fat depth and shrunk body weight were obtained from 218 Nellore steers to predict weights and percentages of carcass retail product, pistola retail product and fat trimmings. After slaughter, carcasses were deboned and weighed and percentages of retail cuts were obtained directly. Measurements taken directly in the carcasses explained 97% and 36% of variation in carcass retail product weight and percentage, and 94% and 36% of variation in pistola retail weight and percentage, respectively. Live measurements explained 93% of carcass retail product weight and 39% of carcass retail product percentage. Lower accuracies were observed for pistola retail product weight (R-2=0.87) and percentage (R-2=0.33). Accuracies for fat trimmings weight and percentage were 79% and 55%, respectively. Ultrasound rump fat thickness showed greater correlations with retail product and fat trimmings (weights and percentages) when compared with ultrasound backfat thickness. The weight and percentage of retail products and of trimmable fat can be estimated in Nellore steers from live animal measurements, with similar accuracy to equations developed based on carcass measurements obtained at slaughter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the thickness of the femoral quadriceps and biceps brachii and brachialis muscles bilaterally and the adjacent subcutaneous fat in patients undergoing gastric bypass Roux-en-Y before and after surgery, using ultrasound as the diagnostic method of choice. We studied 12 patients undergoing this surgical method preoperatively and during the first, third, and sixth postoperative months. During these periods, patients were evaluated by ultrasound to determine the thickness of subcutaneous adipose tissue and muscle of the upper and lower limbs. Postoperatively, these patients showed a reduction in the thickness of the upper and lower extremities muscle and adipose tissue as compared to their preoperative values. There was a significant difference in the loss of muscle thickness in all postoperative months and in the thickness of fatty tissue in the sixth month after surgery, compared to the preoperative muscle and fatty tissue thickness. Ultrasound can be considered as the diagnostic method of choice when assessment of the fat and lean body mass is required in morbidly obese patients before and after bariatric surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the perinatal outcomes in hydropic fetuses with congenital microcystic pulmonary lesions that underwent percutaneous, invasive, laser therapy. Method This retrospective study reviews the literature and our experience between 2004 and 2010. Characteristics of the cystic lung lesions, liquor volume (presence of polyhydramnios or not), localization of ablation (vascular vs interstitial) and gestational age at which the procedure was performed were related to outcome (survival). Results In total, 16 fetuses with congenital lung lesions underwent invasive percutaneous laser ablation, seven performed in our center and nine published cases. Survival rate was higher in fetuses with a subsequent postnatal diagnosis of bronchopulmonary sequestration (87.5%) compared with congenital adenomatoid malformation (28.6%; p?=?0.04). The technique of vascular ablation was more successful (100%) than interstitial ablation (25.0%, p?<?0.01). Conclusion Percutaneous vascular laser ablation seems to be effective for bronchopulmonary sequestration in hydropic fetuses. Outcomes were worst following interstitial ablation for microcystic congenital adenomatoid with hydrops. (C) 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to determine ultrasound (US) arthrography diagnostic accuracy in patients with recurrent shoulder dislocation by comparing US arthrography and magnetic resonance arthrography (MRA) with intraoperative findings. Fifty-six consecutive patients with diagnosis of chronic anterior instability of the shoulder were evaluated for assessment of bone and soft tissue lesions by three radiologists. Twenty-five cases were confirmed by surgery. Sensitivity, specificity, inter-and intraobserver agreement were calculated. Ultrasound sensitivity ranged from 20% to 100% and specificity from 25% to 90%. MRA sensitivity ranged from 80% to 100% and specificity from 50% to 100%. Interobserver agreement was good for MRA (0.54-0.70) and fair for US arthrography (0.19-0.40). Despite a higher interobserver variability for US arthrography than for MRA, our results indicate that US is capable of demonstrating bone and soft tissue lesions related to chronic instability of the shoulder in the presence of intra-articular fluid. (E-mail: marcelo_simao@hotmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: this study investigated the feelings of women regarding end-of-life decision making after ultrasound diagnosis of a lethal fetal malformation. The aim of this study was to present the decision making process of women that chose for pregnancy termination and to present selected speeches of women about their feelings. Design: open psychological interviews conducted by a psychologist immediately after the diagnosis of fetal malformation by ultrasound. Analysis of the results was performed through a content analysis technique. Setting: the study was carried out at a public university hospital in Brazil. Participants: 249 pregnant women who had received the diagnosis of a severe lethal fetal malformation. Findings: fetal anencephaly was the most frequent anomaly detected in 135 cases (54.3%). Termination of pregnancy was decided by 172 (69.1%) patients and legally authorised by the judiciary (66%). The reason for asking for termination was to reduce suffering in all of them. In the 77 women who chose not to terminate pregnancy (30.9%), the reasons were related to feelings of guilt (74%). Key conclusions: the results support the importance of psychological counselling for couples when lethal fetal malformation is diagnosed. The act of reviewing moral and cultural values and elements of the unconscious provides assurance in the decision-making process and mitigates the risk of emotional trauma and guilt that can continue long after the pregnancy is terminated. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The use of external sources of energy may accelerate the setting rate of glass ionomer cements (GICs) allowing better initial mechanical properties. Aim. To investigate the influence of ultrasound and halogen light on the microleakage and hardness of enamel adjacent to GIC restorations, after artificial caries challenge. Design. Cavities were prepared in 60 primary canines, restored with GIC, and randomly distributed into three groups: control group (CG), light group (LG) - irradiation with a halogen lightcuring unit for 60 s, and ultrasonic group (UG) application of ultrasonic scaler device for 15 s. All specimens were then submitted to a cariogenic challenge in a pH cycling model. Half of sample in each group were immersed in methylene blue for 4 h and sectioned for dye penetration analysis. The remaining specimens were submitted to Knoop cross-sectional microhardness assessments, and mineral changes were calculated for adjacent enamel. Results. Data were compared using Kruskal-Wallis test and two- way ANOVA with 5% significance. Higher dye penetration was observed for the UG (P < 0.01). No significant mineral changes were observed between groups (P = 0.844). Conclusion. The use of halogen light- curing unit does not seem to interfere with the properties of GICs, whereas the use of ultrasound can affect its marginal sealing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the ultrasound-assisted synthesis of saturated aliphatic esters from synthetic aliphatic acids and either methanol or ethanol. The products were isolated in good yields after short reaction times under mild conditions. (C) 2011 Elsevier BM. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left-sided and 26 right-sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver-up), lung-to-head ratio (LHR) and observed/expected LHR (o/e-LHR), observed/expected contralateral and total fetal lung volume (o/e-ContFLV and o/e-TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US-FLW), observed/expected contralateral and main pulmonary artery diameter (o/e-ContPA and o/eMPA) ratios and the contralateral vascularization index (Cont-VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH). Results Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/eLHR, liver-up, o/e-ContFLV, o/e-TotFLV, US-FLW, o/eContPA, o/e-MPA and Cont-VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver-operating characteristics curves indicated that measuring total lung volumes (o/e-TotFLV and US-FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e-LHR and o/e-ContFLV; P < 0.05), and Cont-VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001). Conclusions Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont-VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white-to-white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add-on intraocular lenses (IOLs). SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Case series. METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross-sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus-to-sulcus (STS), angle-to-angle (ATA), and sclera-to-sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes. RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217). CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE), in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men) who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training) and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58). There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85), aortic regurgitation (kappa = 0.89), and tricuspid regurgitation (Kappa = 0.74). A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.