29 resultados para Molecular Diagnostic Techniques

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Holsback L., Pena H.F.J., Ragozo A., Lopes E. G., Gennari S. M. & Soares R. M. 2012. Serologic and molecular diagnostic and bioassay in mice for detection of Toxoplasma gondii in free range chickens from Pantanal of Mato Grosso do Sul. Pesquisa Veterinaria Brasileira 32(8): 721-726. Setor de Veterinaria e Producao Animal, Universidade Estadual do Norte do Parana, Campus Luiz Meneghel, Rodovia BR 369 Km 54, Bandeirantes, PR 86360-000, Brazil. E-mail: lhsfertonani@uenp.edu.br The aim of this study was to investigate the occurrence of Toxoplasma gondii and compare the results obtained in the Modified Agglutination Test (MAT), Polimerase Chain Reaction (PCR) and bioassay in mice. In order to accomplish this, 40 free-range chickens from eight farms in neighboring areas to the Pantanal in Nhecolandia, Mato Grosso do Sul, were euthanized and blood samples, brain and heart were collected. The occurrence of anti-T. gondii antibodies found in chickens was 67.5% (27 samples), considering as a cutoff point the dilution 1:5. Among the samples analyzed, 7 (25.9%) were positive in the dilution 1: 5, 3 (11.1%) in 1: 10, 2 (7.4%) in 1: 20, 3 (11.1%) in 1: 320, 1 (3.7%) in 1: 640, 3 (11.1%) in 1: 1280, 2 (7.4%) in 1: 2560, 4 (14.8%) in 1: 5120 and 2 (7.4%) in 1: 10.240. From the mixture of tissue samples (brain and heart) from the chickens analyzed, 16 (40%) presented electrophoretic bands compatible with T. gondii by PCR (gene B1). In the comparison of techniques, 59.26% positivity in PCR was revealed among animals that were seropositive in MAT (cutoff 1: 5). From 141 inoculated mice, six (4.44%) died of acute toxoplasmosis between 15 and 23 days after inoculation. Surviving mice were sacrificed at 74 days after inoculation, and a total of 28 cysts were found in the brains of 10 distinct groups. From the seropositive hens, 27 bioassays were performed and 11 (40.7%) isolates were obtained. A greater number of isolations happened in mice that were inoculated with tissues from chickens that had high titers for anti-T. gondii antibodies. Chronic infection in mice was observed in nine groups (33.3%) from five different properties. Among the surviving mice, 25.6% were positive for T. gondii in MAT (1: 25). From mice positive in PCR, 87.5% were also positive in MAT. Among the PCR-negative mice, 5.2% were positive for T. gondii in MAT. It can be concluded through this study that the occurrence of infecton by T. gondii in the rural properties studied was high, that PCR directed to gene B1 does not confirm the viability of the parasite, but it can be used as a screening method for the selection of chickens infected by T. gondii, that the animals with titer greater than 10 must be prioritized for the selection of animals for bioassay, since for them, the chances of isolating the parasite are greater and that seroconversion in experimentally infected mice is not a good indicator for isolating the agent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Adult community-acquired pneumonia (CAP) is a relevant worldwide cause of morbidity and mortality, however the aetiology often remains uncertain and the therapy is empirical. We applied conventional and molecular diagnostics to identify viruses and atypical bacteria associated with CAP in Chile. Methods We used sputum and blood cultures, IgG/IgM serology and molecular diagnostic techniques (PCR, reverse transcriptase PCR) for detection of classical and atypical bacteria (Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella pneumoniae) and respiratory viruses (adenovirus, respiratory syncytial virus (RSV), human metapneumovirus, influenza virus, parainfluenzavirus, rhinovirus, coronavirus) in adults >18 years old presenting with CAP in Santiago from February 2005 to September 2007. Severity was qualified at admission by Fine's pneumonia severity index. Results Overall detection in 356 enrolled adults were 92 (26%) cases of a single bacterial pathogen, 80 (22%) cases of a single viral pathogen, 60 (17%) cases with mixed bacterial and viral infection and 124 (35%) cases with no identified pathogen. Streptococcus pneumoniae and RSV were the most common bacterial and viral pathogens identified. Infectious agent detection by PCR provided greater sensitivity than conventional techniques. To our surprise, no relationship was observed between clinical severity and sole or coinfections. Conclusions The use of molecular diagnostics expanded the detection of viruses and atypical bacteria in adults with CAP, as unique or coinfections. Clinical severity and outcome were independent of the aetiological agents detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micelles composed of amphiphilic copolymers linked to a radioactive element are used in nuclear medicine predominantly as a diagnostic application. A relevant advantage of polymeric micelles in aqueous solution is their resulting particle size, which can vary from 10 to 100 nm in diameter. In this review, polymeric micelles labeled with radioisotopes including technetium (99mTc) and indium (111In), and their clinical applications for several diagnostic techniques, such as single photon emission computed tomography (SPECT), gamma-scintigraphy, and nuclear magnetic resonance (NMR), were discussed. Also, micelle use primarily for the diagnosis of lymphatic ducts and sentinel lymph nodes received special attention. Notably, the employment of these diagnostic techniques can be considered a significant tool for functionally exploring body systems as well as investigating molecular pathways involved in the disease process. The use of molecular modeling methodologies and computer-aided drug design strategies can also yield valuable information for the rational design and development of novel radiopharmaceuticals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 degrees C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p < 0.001). No differences were found between groups 1 and 2 (p > 0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reproductive diseases are a great barrier to dairy production, as they diminish fertility and cause economic loss. In this context, endometritis plays an important role. Different diagnostic techniques exist for endometritis that vary in sensitivity and specificity. This work aimed to evaluate and compare ultrasonographic and histopathological examinations, and combinations thereof, for the diagnosis of endometritis by determining their sensitivity, specificity, and kappa agreement coefficients using endometrial cytology as the gold standard. We developed an adaptive reading score to perform histological examination of the uterus. In this study, 76 Holstein-Friesian cows, 21 to 47 d postpartum, without vaginal catarrh were submitted to gynecological examinations, including ultrasonographic examination, an endometrial cytology examination, and a uterine biopsy. Our results indicate that ultrasonography is a practical and effective diagnostic method, and a combination of the determination of intrauterine fluid and cervical diameter was the most efficient ultrasonographic method, with 50% sensitivity and 88% specificity. Histopathological examination was a useful diagnostic method that provided rich detail on endometrial inflammation, and allowed evaluation of different components of the tissue such as the epithelium, lamina propria, endometrial glands, and blood vessels; this method had 44% sensitivity and 92% specificity for diagnosis of endometritis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report on a boy presenting submucous cleft palate, hydronephrosis, ventriculoseptal defect, aniridia, and developmental delay. Additional material on 11p13 was cytogenetically visible and array analyses identified a duplicated segment on 15q25-26 chromosome region; further, array analyses revealed a small deletion (49?kb) at 11p13 region involving the ELP4 gene and a duplication at 8p23.1. Results were confirmed with both molecular and molecular cytogenetics techniques. Possibilities for etiological basis of clinical phenotype are discussed. (c) 2012 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Spatial linear models have been applied in numerous fields such as agriculture, geoscience and environmental sciences, among many others. Spatial dependence structure modelling, using a geostatistical approach, is an indispensable tool to estimate the parameters that define this structure. However, this estimation may be greatly affected by the presence of atypical observations in the sampled data. The purpose of this paper is to use diagnostic techniques to assess the sensitivity of the maximum-likelihood estimators, covariance functions and linear predictor to small perturbations in the data and/or the spatial linear model assumptions. The methodology is illustrated with two real data sets. The results allowed us to conclude that the presence of atypical values in the sample data have a strong influence on thematic maps, changing the spatial dependence structure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer (R); Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. Methods: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis-One Use Plus, Moria (R)). CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. Results: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p<0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p<0, 05), 8 of these being related to the first sign of flattening. Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05). There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p<0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p<0.05). Conclusion: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We measured polycyclic aromatic hydrocarbons (PAHs) in bulk precipitation in the Fortaleza metropolitan area, Ceara, Brazil, for the first time. Because little information is available concerning PAHs in tropical climatic regions, we assessed their spatial distribution and possible sources and the influence of urban activities on the depositional fluxes of PAHs in bulk precipitation. The concentrations of individual and total PAHs (Sigma(PAHs)) in bulk precipitation ranged from undetectable to 133.9 ng.L-1 and from 202.6 to 674.8 ng.L-1, respectively. The plume of highest concentrations was most intense in a zone with heavy automobile traffic and favorable topography for the concentration of emitted pollutants. The depositional fluxes of PAHs in bulk precipitation calculated in this study (undetectable to 0.87 mu g.m(-2).month(-1)) are 4 to 27 times smaller than those reported from tourist sites and industrial and urban areas in the Northern Hemisphere. Diagnostic ratio analyses of PAH samples showed that the major source of emissions is gasoline exhaust, with a small percentage originating from diesel fuel. Contributions from coal and wood combustion were also found. Major economic activities appear to contribute to pollutant emissions. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two myotoxic and noncatalytic Lys49-phospholipases A2 (braziliantoxin-II and MT-II) and a myotoxic and catalytic phospholipase A2 (braziliantoxin-III) from the venom of the Amazonian snake Bothrops brazili were crystallized. The crystals diffracted to resolutions in the range 2.562.05 angstrom and belonged to space groups P3121 (braziliantoxin-II), P6522 (braziliantoxin-III) and P21 (MT-II). The structures were solved by molecular-replacement techniques. Both of the Lys49-phospholipases A2 (braziliantoxin-II and MT-II) contained a dimer in the asymmetric unit, while the Asp49-phospholipase A2 braziliantoxin-III contained a monomer in its asymmetric unit. Analysis of the quaternary assemblies of the braziliantoxin-II and MT-II structures using the PISA program indicated that both models have a dimeric conformation in solution. The same analysis of the braziliantoxin-III structure indicated that this protein does not dimerize in solution and probably acts as a monomer in vivo, similar to other snake-venom Asp49-phospholipases A2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a viabilidade e o potencial do uso da tomografia de coerência óptica em conjunto com um broncoscópio convencional na avaliação das vias aéreas. MÉTODOS: Estudo piloto baseado em um modelo experimental ex vivo com três animais: um coelho adulto da raça Nova Zelândia e dois suínos da raça Landrace. Um cateter de imagem de tomografia de coerência óptica foi inserido no canal de trabalho de um broncoscópio flexível para alcançarmos a traqueia distal dos animais. As imagens foram obtidas sistematicamente em toda a traqueia ao longo das paredes, partindo da porção distal para a proximal. RESULTADOS: O cateter de imagem se adaptou com facilidade ao canal de trabalho do broncoscópio. Imagens em alta resolução de cortes transversais da traqueia foram obtidas em tempo real, sendo delineadas microestruturas, tais como epitélio, submucosa, cartilagem e camada adventícia nas paredes anteriores e laterais da traqueia. As camadas correspondentes do epitélio, mucosa e cartilagens foram claramente diferenciadas. Na parede posterior, foi possível identificar mucosa, submucosa e musculatura traqueal. CONCLUSÕES: O uso de tomógrafo de coerência óptica em conjunto com um broncoscópio flexível é viável. A tomografia de coerência óptica produz imagens de alta resolução que permitem visualizar a microanatomia da traqueia, inclusive estruturas que normalmente são visualizadas somente na histologia convencional.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: In orthodontics, determining the facial type is a key element in the prescription of a correct diagnosis. In the early days of our specialty, observation and measurement of craniofacial structures were done directly on the face, in photographs or plaster casts. With the development of radiographic methods, cephalometric analysis replaced the direct facial analysis. Seeking to validate the analysis of facial soft tissues, this work compares two different methods used to determining the facial types, the anthropometric and the cephalometric methods. METHODS: The sample consisted of sixty-four Brazilian individuals, adults, Caucasian, of both genders, who agreed to participate in this research. All individuals had lateral cephalograms and facial frontal photographs. The facial types were determined by the Vert Index (cephalometric) and the Facial Index (photographs). RESULTS: The agreement analysis (Kappa), made for both types of analysis, found an agreement of 76.5%. CONCLUSIONS: We concluded that the Facial Index can be used as an adjunct to orthodontic diagnosis, or as an alternative method for pre-selection of a sample, avoiding that research subjects have to undergo unnecessary tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fig (Ficus carica L.) is a fruit tree of great world importance and, therefore, the genetic improvement becomes an important field of research for better crops, being necessary to gather information on this species, mainly regarding its genetic variability so that appropriate propagation projects and management are made. The improvement programs of fig trees using conventional procedures in order to obtain new cultivars are rare in many countries, such as Brazil, especially due to the little genetic variability and to the difficulties in obtaining plants from gamete fusion once the wasp Blastophaga psenes, responsible for the natural pollinating, is not found in Brazil. In this way, the mutagenic genetic improvement becomes a solution of it. For this reason, in an experiment conducted earlier, fig plants formed by cuttings treated with gamma ray were selected based on their agronomic characteristics of interest. We determined the genetic variability in these fig tree selections, using RAPD and AFLP molecular markers, comparing them to each other and to the Roxo-de-Valinhos, used as the standard. For the reactions of DNA amplification, 140 RAPD primers and 12 primer combinations for AFLP analysis were used. The selections did not differ genetically between themselves and between them and the Roxo-de-Valinhos cultivar. Techniques that can detect polymorphism between treatments, such as DNA sequencing, must be tested. The phenotypic variation of plants may be due to epigenetic variation, necessitating the use of techniques with methylation-sensitive restriction enzymes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorene-based systems have shown great potential as components in organic electronics and optoelectronics (organic photovoltaics, OPVs, organic light emitting diodes, OLEDs, and organic transistors, OTFTs). These systems have drawn attention primarily because they exhibit strong blue emission associated with relatively good thermal stability. It is well-known that the electronic properties of polymers are directly related to the molecular conformations and chain packing of polymers. Here, we used three oligofluorenes (trimer, pentamer, and heptamer) as model systems to theoretically investigate the conformational properties of fluorene molecules, starting with the identification of preferred conformations. The hybrid exchange correlation functional, OPBE, and ZINDO/S-CI showed that each oligomer exhibits a tendency to adopt a specific chain arrangement, which could be distinguished by comparing their UV/vis electronic absorption and C-13 NMR spectra. This feature was used to identify the preferred conformation of the oligomer chains in chloroform-cast films by comparing experimental and theoretical UV/vis and C-13 NMR spectra. Moreover, the oligomer chain packing and dynamics in the films were studied by DSC and several solid state NMR techniques, which indicated that the phase behavior of the films may be influenced by the tendency that each oligomeric chain has to adopt a given conformation.