5 resultados para DNA fragment

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Double-stranded pBS plasmid DNA was irradiated with gamma rays at doses ranging from 1 to 12 kGy and electron beams from 1 to 10 kGy. Fragment-size distributions were determined by direct visualization, using atomic force microscopy with nanometer-resolution operating in non-tapping mode, combined with an improved methodology. The fragment distributions from irradiation with gamma rays revealed discrete-like patterns at all doses, suggesting that these patterns are modulated by the base pair composition of the plasmid. Irradiation with electron beams, at very high dose rates, generated continuous distributions of highly shattered DNA fragments, similar to results at much lower dose rates found in the literature. Altogether, these results indicate that AFM could supplement traditional methods for high-resolution measurements of radiation damage to DNA, while providing new and relevant information.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Leaves of Cassia hoffmannseggii, a wild fabaceous species found in the Atlantic Forest, with a severe mosaic symptom were collected in Pernambuco State, Brazil. By transmission electron microscopy, two types of virus particles were found: the first was recognized as particles of a potyvirus, which was later identified as Cowpea aphid-borne mosaic virus; and the second was isometric and present in high concentration. The observation of vesicles at the periphery of chloroplasts suggested a tymovirus infection, which was confirmed by subsequent assays. A serological assay against several tymovirus antisera resulted in positive reaction of this tymo-like virus with an antiserum of Passion fruit yellow mosaic virus. By means of RT-PCR and using degenerated primers for the conserved region of RNA-dependent RNA polymerase (RdRp) gene of tymoviruses, a specific DNA fragment was amplified and sequenced. Based on this sequence, a specific forward primer was synthesized and successfully used to amplify the 3' terminal genome region, containing the partial RdRp gene and the complete coat protein (CP) sequences. The CP was 188 amino acids (aa) long, and the highest CP aa identity was observed with Kennedya yellow mosaic virus (61 %). Based on the current ICTV demarcation criterion, this isolate was considered as a distinct tymovirus and tentatively named as Cassia yellow mosaic-associated virus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hemophilia A is the most common X-linked bleeding disorder; it is caused by deficiency of coagulation factor VIII (FVIII). Replacement therapy with rFVIII produced from human cell line is a major goal for treating hemophilia patients. We prepared a full-length recombinant FVIII (FVIII-FL), using the pMFG-P140K retroviral vector. The IRES DNA fragment was cloned upstream to the P140K gene, providing a 9.34-kb bicistronic vector. FVIII-FL cDNA was then cloned upstream to IRES, resulting in a 16.6-kb construct. In parallel, an eGFP control vector was generated, resulting in a 10.1-kb construct. The 293T cells were transfected with these constructs, generating the 293T-FVIII-FL/P140K and 293T-eGFP/P140K cell lines. In 293T-FVIII-FL/P140K cells, FVIII and P140K mRNAs levels were 4,410 (+/- 931.7)- and 295,400 (+/- 75,769)-fold higher than in virgin cells. In 293T-eGFP/P140K cells, the eGFP and P140K mRNAs levels were 1,501,000 (+/- 493,700)- and 308,000 (+/- 139,300)-fold higher than in virgin cells. The amount of FVIII-FL was 0.2 IU/mL and 45 ng/mL FVIII cells or 4.4 IU/mu g protein. These data demonstrate the efficacy of the bicistronic retroviral vector expressing FVIII-FL and MGMT(P140K), showing that it could be used for producing the FVIII-FL protein in a human cell line.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Cytotoxic T lymphocyte-associated factor 4 (CTLA-4) functions as a negative regulator of T cell-mediated immune response. Molecular changes associated to CTLA-4 gene polymorphisms could reduce its ability to suppress and control lymphocyte proliferation. Aims: To evaluate the frequency of CTLA-4 gene polymorphisms in chronic hepatitis C virus (HCV) infected patients and correlate to clinical and histological findings. Methods: We evaluated 112 HCV-infected subjects prospectively selected and 183 healthy controls. Clinical and liver histological data were analysed. - 318C > T, A49G and CT60 CTLA-4 single-nucleotide polymorphisms (SNPs) were studied by PCR-RFLP and AT(n) polymorphism by DNA fragment analysis by capillary electrophoresis in automatic sequencer. Results: Eight AT repetitions in 3' UTR region were more frequent in HCV-infected subjects. We found a positive association of -318C and + 49G with HCV genotype 3 (P = 0.008, OR 9.13, P = 0.004, OR 2.49 respectively) and an inverse association of both alleles with HCV genotype 1 (P = 0.020, OR 0.19, P = 0.002, OR 0.38 respectively). Allele + 49G was also associated to aminotransferases quotients > 3 (qALT, P = 0.034, qAST, P = 0.041). Allele G of CT60 SNP was also associated with qAST > 3 (P = 0.012). Increased number of AT repetitions was positively associated to severe necroinflammatory activity scores in liver biopsies (P = 0.045, OR 4.62). Conclusion: CTLA-4 gene polymorphisms were associated to HCVinfection. Eight AT repetitions were more prevalent in HCV-infected subjects. - 318C and + 49G alleles were associated to genotypes 1 and 3 infections and increased number of AT repetitions in 3' UTR region favoured severe necroinflammatory activity scores in liver biopsies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300Vcm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215 000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.