4 resultados para DISINFECTANTS

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This theoretical study proposes a reflection on the intrinsic resistance of the subclass Coccidia, particularly the genus Cryptosporidium, considered to be potential pathogens for immunocompromised patients, and the implications for nursing practice. Currently, the international and national guidelines support the chemical disinfection of digestive system endoscopes after their cleansing as a safe and effective procedure. However, studies show that microorganisms of the subclass Coccidia, namely Cryptosporidium, responsible for enteric infection, are more resistant than mycobacteria and are not inactivated by high-level disinfectants, except for hydrogen peroxide 6% and 7.5%, which are not currently available in Brazil. We conclude that the legislation should include this agent among test microorganisms for approving high-level disinfectants. Health authorities should make efforts to ensure that healthcare institutions have access to effective disinfectants against Cryptosporidium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Listeria monocytogenes is a foodborne pathogen of great concern due to the high fatality rates of listeriosis. The consumption of RTE vegetables has increased in Brazil over the last two decades, but little is known about the risks associated to the consumption of these products. This study evaluated the prevalence and counts of L. monocytogenes in 512 packages of ready-to-eat vegetables marketed in Sao Paulo. The isolates were characterized for their serotypes, ribotypes, positivity for virulence genes inIA, inIC and inIJ, resistance to chlorine, growth rate variability and capability to form biofilm on stainless steel (AISI 304, #4) coupons. L. monocytogenes was detected in 3.1% of the samples. Only five samples presented countable levels, with counts between 1.0x10(1) and 2.6x10(2) CFU/g. Isolates belonged to serotypes 1/2b or 4b and most were positive for genes inIC and inIJ. Ribotypable isolates were grouped into four groups: 1038 (69.4%). 19175 (11.3%), 19191 (17.7%) and 18604 (one isolate). Most isolates survived to exposure to 125 ppm of a chlorine-based disinfectant for 3 min. All isolates were capable to attach to the coupons, reaching counts above 4 log(10) CFU/cm(2) and the growth rate (mu) at 25 degrees C of the majority of the isolates varied between 0.1 and 0.2 log OD/h, but for few strains the mu was as high as 0.26 log OD/h. Results of this survey indicate that RTE vegetables may be vehicles of L. monocytogenes strains with limited variation in serotype, ribotype and virulence factors but varying significantly in resistance to chlorine disinfectants, capability of forming biofilm and growth rate. Data obtained is of foremost importance to serve as baseline for the development of scientific-based policies to control the incidence of L. monocytogenes in RTE vegetables in Brazil. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background Prior to the selection of disinfectants for low, intermediate and high (sterilizing) levels, the decimal reduction time, D-value, for the most common and persistent bacteria identified at a health care facility should be determined. Methods The D-value was determined by inoculating 100 mL of disinfecting solution with 1 mL of a bacterial suspension (104 – 105 CFU/mL for vegetative and spore forms). At regular intervals, 1 mL aliquots of this mixture were transferred to 8 mL of growth media containing a neutralizing agent, and incubated at optimal conditions for the microorganism. Results The highest D-values for various bacteria were determined for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0) – E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min) and 0.1% for B. stearothermophilus (D = 3.5 min) and B. subtilis (D = 3.2 min); (iii) 2.0% glutaraldehyde (pH 7.4) – B. stearothermophilus, B. subtilis (D = 25 min) and E. coli (D = 7.1 min); (iv) 0.5% formaldehyde (pH 6.5) – B. subtilis (D = 11.8 min), B. stearothermophilus (D = 10.9 min) and A. calcoaceticus (D = 5.2 min); (v) 2.0% chlorhexidine (pH 6.2) – B. stearothermophilus (D = 9.1 min), and at 0.4% for E. cloacae (D = 8.3 min); (vi) 1.0% Minncare® (peracetic acid and hydrogen peroxide, pH 2.3) – B. stearothermophilus (D = 9.1 min) and E. coli (D = 6.7 min). Conclusions The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations showed that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasizes the importance and need to develop routine and novel programs to evaluate product utility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.