2 resultados para CARRIER SYSTEM

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Liposomes have been employed as potential drug carriers. However, after their in vivo administration, they can be destabilized by proteins of complement system, contributing to the clearance of vesicles from blood circulation. Antioxidant flavonoids such as quercetin have been reported to be beneficial to human health, but their low water solubility and bioavailability limit their enteric administration. Therefore, the development of appropriate flavonoid-carriers could be of great importance to drug therapy. The aim of the present study was to evaluate the activation of human complement system proteins by liposomes composed of soya phosphatidylcholine (SPC) and cholesterol (CHOL) or cholesteryl ethyl ether (CHOL-OET) loaded with quercetin or not. The consumption of complement, via classical (CP) and alternative (AP) pathways, by different vesicles was evaluated using a hemolytic assay and quantitative determination of iC3b and natural antibodies deposited on empty liposomal surfaces by ELISA. The main results showed that empty liposomes composed of large amounts of CHOL consumed more complement components than the others for both CP and AP. Furthermore, replacement of CHOL with CHOL-OET reduced complement consumption via both CP and AP. Incorporation of quercetin did not change CP and AP consumption. Deposition of iC3b, IgG and IgM in vesicles composed of SPC: CHOL-OET at a molar ratio of 1.5:1 was lower compared to the others. Taken together, these observations suggest that liposomes composed of SPC: CHOL-OET at a molar ratio of 1.5:1 are the most appropriate among the vesicles studied herein to be used as a drug carrier system in further investigations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The free-carrier absorption cross-section sigma of a magnetic colloid composed of magnetite nanoparticles dispersed in oil is obtained by using the Z-scan technique in different experimental conditions of the laser beam. We show that it is possible to obtain sigma with picosecond pulsed and millisecond chopped beams with pulse frequencies smaller than about 30 Hz. For higher pulse frequencies, the heating of the colloidal system triggers the appearance of the Soret effect. This effect artificially increases the value of sigma calculated from the experimental results. The limits of the different experimental setups are discussed. (C) 2012 Optical Society of America