11 resultados para Artificial Organs, Ventricular Assist Device, Centrifugal Pump, Computation Fluid Dynamics

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Several models have been designed to predict survival of patients with heart failure. These, while available and widely used for both stratifying and deciding upon different treatment options on the individual level, have several limitations. Specifically, some clinical variables that may influence prognosis may have an influence that change over time. Statistical models that include such characteristic may help in evaluating prognosis. The aim of the present study was to analyze and quantify the impact of modeling heart failure survival allowing for covariates with time-varying effects known to be independent predictors of overall mortality in this clinical setting. Methodology: Survival data from an inception cohort of five hundred patients diagnosed with heart failure functional class III and IV between 2002 and 2004 and followed-up to 2006 were analyzed by using the proportional hazards Cox model and variations of the Cox's model and also of the Aalen's additive model. Principal Findings: One-hundred and eighty eight (188) patients died during follow-up. For patients under study, age, serum sodium, hemoglobin, serum creatinine, and left ventricular ejection fraction were significantly associated with mortality. Evidence of time-varying effect was suggested for the last three. Both high hemoglobin and high LV ejection fraction were associated with a reduced risk of dying with a stronger initial effect. High creatinine, associated with an increased risk of dying, also presented an initial stronger effect. The impact of age and sodium were constant over time. Conclusions: The current study points to the importance of evaluating covariates with time-varying effects in heart failure models. The analysis performed suggests that variations of Cox and Aalen models constitute a valuable tool for identifying these variables. The implementation of covariates with time-varying effects into heart failure prognostication models may reduce bias and increase the specificity of such models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A low-cost circuit was developed for stable and efficient maximum power point (MPP) tracking in autonomous photo voltaic-motor systems with variable-frequency drives (VFDs). The circuit is made of two resistors, two capacitors, and two Zener diodes. Its input is the photovoltaic (PV) array voltage and its output feeds the proportional-integral-derivative (PID) controller usually integrated into, the drive. The steady-state frequency-voltage oscillations induced by the circuit were treated in a simplified mathematical model, which was validated by widely characterizing a PV-powered centrifugal pump. General procedures for circuit and controller tuning were recommended based on model equations. The tracking circuit presented here is widely applicable to PV-motor system with VFDs, offering an. efficient open-access technology of unique simplicity. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: There is no consensus on the optimal method to measure delivered dialysis dose in patients with acute kidney injury (AKI). The use of direct dialysate-side quantification of dose in preference to the use of formal blood-based urea kinetic modeling and simplified blood urea nitrogen (BUN) methods has been recommended for dose assessment in critically-ill patients with AKI. We evaluate six different blood-side and dialysate-side methods for dose quantification. Methods: We examined data from 52 critically-ill patients with AKI requiring dialysis. All patients were treated with pre-dilution CWHDF and regional citrate anticoagulation. Delivered dose was calculated using blood-side and dialysis-side kinetics. Filter function was assessed during the entire course of therapy by calculating BUN to dialysis fluid urea nitrogen (FUN) ratios q/12 hours. Results: Median daily treatment time was 1,413 min (1,260-1,440). The median observed effluent volume per treatment was 2,355 mL/h (2,060-2,863) (p<0.001). Urea mass removal rate was 13.0 +/- 7.6 mg/min. Both EKR (r(2)=0.250; p<0.001) and K-D (r(2)=0.409; p<0.001) showed a good correlation with actual solute removal. EKR and K-D presented a decline in their values that was related to the decrease in filter function assessed by the FUN/BUN ratio. Conclusions: Effluent rate (ml/kg/h) can only empirically provide an estimated of dose in CRRT. For clinical practice, we recommend that the delivered dose should be measured and expressed as K-D. EKR also constitutes a good method for dose comparisons over time and across modalities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims to evaluate the cytocompatibility of injectable and moldable restorative biomaterials based on granules of dense or porous biphasic calcium phosphates (BCPs) with human primary mesenchymal cells, in order to validate them as tools for stem cell-induced bone regeneration. Porous hydroxyapatite (HA) and HA/beta-tricalcium phosphate (beta-TCP) (60: 40) granules were obtained by the addition of wax spheres and pressing at 20 MPa, while dense materials were compacted by pressing at 100 MPa, followed by thermal treatment (1100 degrees C), grinding, and sieving. Extracts were prepared by 24-h incubation of granules on culture media, with subsequent exposition of human primary mesenchymal cells. Three different cell viability parameters were evaluated on the same samples. Scanning electron microscopy analysis of the granules revealed distinct dense and porous surfaces. After cell exposition to extracts, no significant differences on mitochondrial activity (2,3-bis(2-methoxy-4-nitro-5-sulfophenly)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide) or cell density (Crystal Violet Dye Elution) were observed among groups. However, Neutral Red assay revealed that dense materials extracts induced lower levels of total viable cells to porous HA/beta-TCP (P < 0.01). Calcium ion content was also significantly lower on the extracts of dense samples. Porogenic treatments on BCP composites do not affect cytocompatibility, as measured by three different parameters, indicating that these ceramics are well suited for further studies on future bioengineering applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the numerical solution of complex fluid dynamics problems using a new bounded high resolution upwind scheme (called SDPUS-C1 henceforth), for convection term discretization. The scheme is based on TVD and CBC stability criteria and is implemented in the context of the finite volume/difference methodologies, either into the CLAWPACK software package for compressible flows or in the Freeflow simulation system for incompressible viscous flows. The performance of the proposed upwind non-oscillatory scheme is demonstrated by solving two-dimensional compressible flow problems, such as shock wave propagation and two-dimensional/axisymmetric incompressible moving free surface flows. The numerical results demonstrate that this new cell-interface reconstruction technique works very well in several practical applications. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of estradiol benzoate (EB) and estradiol cypionate (EC) on induction of ovulation after a synchronized LH surge and on fertility of Bos indicus females submitted to timed AI (TAI) were evaluated. In Experiment 1, ovariectomized Nelore heifers were used to evaluate the effect of EB (n = 5) and EC (n = 5) on the circulating LH profile. The LH surge timing (19.6 and 50.5 h; P = 0.001), magnitude (20.5 and 9.4 ng/mL; P = 0.005), duration (8.6 and 16.5 h; P = 0.001), and area under the LH curve (158.6 and 339.4 ng/mL; P = 0.01) differed between the EB and EC treatments, respectively. In Experiment 2 (follicular responses; n = 60) and 3 (pregnancy per AI; P/AI; n = 953) suckled Bos indicus beef cows submitted to an estradiol/progesterone-based synchronization protocol were assigned to receive one of two treatments to induce synchronized ovulation: 1 mg of EB im 24 h after progesterone (P4) device removal or 1 mg of EC im at P4 device removal. There was no difference (P > 0.05) between EB and EC treatments on follicular responses (maximum diameter of the ovulatory follicle, 13.1 vs. 13.9 mm; interval from progesterone device removal to ovulation, 70.2 vs. 68.5 h; and ovulation rate, 77.8 vs. 82.8%, respectively). In addition, P/AI was similar (P < 0.22) between the cows treated with EB (57.5%; 277/482) and EC (61.8%; 291/471). In conclusion, despite pharmacologic differences, both esters of estradiol administered either at P4 device removal (EC) or 24 h later (EB) were effective in inducing an LH surge which resulted in synchronized ovulations and similar P/AI in suckled Bos indicus beef cows submitted to TAI. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, molecular analysis caused the South American Viguiera Kunth species to be transferred to Aldama La Llave. However, the circumscription has not been established for certain of the South American species, including Aldama filifolia (Sch. Bip. ex Baker) E. E. Schill. & Panero, A. linearifolia (Chodat) E. E. Schill. & Panero and A. trichophylla (Dusen) Magenta (comb. nov.), which had previously been treated as synonyms because of their high similarity. Therefore, the present study aimed to evaluate the anatomy of the aerial organs, and the yield and chemical composition of the essential oils from these three species, to determine the differences among them and thereby assist in species distinction. The anatomical analysis identified characteristics unique to each species, which are primarily related to the position and occurrence of secretory structures. Histochemical analysis demonstrated that the glandular trichomes and the canals secrete lipophilic substances, which are characterised by the presence of essential oils. The analysis of these essential oils identified monoterpenes as their major constituent and allowed for the recognition of chemical markers for each species. The anatomical and chemical characteristics identified by the present study confirmed that the studied samples belong to three distinct taxa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA (R) in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods: Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conex˜aoR , (E) EmfilsR , (I) INPR , (S) SINR , and (T) Titanium FixR . The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20Ncmusing a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronicmicroscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results: Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion: An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA® in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a system for classification of industrial steel pieces by means of magnetic nondestructive device. The proposed classification system presents two main stages, online system stage and off-line system stage. In online stage, the system classifies inputs and saves misclassification information in order to perform posterior analyses. In the off-line optimization stage, the topology of a Probabilistic Neural Network is optimized by a Feature Selection algorithm combined with the Probabilistic Neural Network to increase the classification rate. The proposed Feature Selection algorithm searches for the signal spectrogram by combining three basic elements: a Sequential Forward Selection algorithm, a Feature Cluster Grow algorithm with classification rate gradient analysis and a Sequential Backward Selection. Also, a trash-data recycling algorithm is proposed to obtain the optimal feedback samples selected from the misclassified ones.