24 resultados para flow-rate


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple and sensitive method using solid phase microextraction (SPME) and liquid chromatography (LC) with heated online desorption (SPME-LC) was developed and validated to analyze anticonvulsants (AEDs) in human plasma samples. A heated lab-made interface chamber was used in the desorption procedure, which allowed the transference of the whole extracted sample. The SPME conditions were optimized by applying an experimental design. Important factors are discussed such as fiber coating types, pH, extraction time and desorption conditions. The drugs were analyzed by LC, using a C18 column (150 mm x 4.6 mm x 5 mm); and 50 mmol L-1, pH 5.50 ammonium acetate buffer : acetonitrile : methanol (55 : 22 : 23 v/v) as the mobile phase with a flow rate of 0.8 mL min(-1). The suggested method presented precision (intra-assay and inter-assay), linearity and limit of quantification (LOQ) all adequate for the therapeutic drug monitoring (TDM) of AEDs in plasma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo desse trabalho é apresentar e discutir a determinação dos parâmetros de dispersão de ar em células mecânicas de flotação, em circuitos industriais brasileiros. Foram investigados os circuitos rougher e scavenger das usinas RPM, Taquari-Vassouras, Copebras e Fosfértil-Catalão (atual Vale Fertilizantes). Nas usinas RPM e Taquari-Vassouras, foram determinados a velocidade superficial do ar (Jg), o hold-up do ar (εg), o diâmetro médio de bolhas (d32) e o fluxo de área superficial de bolhas (Sb). Para as outras usinas, foram determinados somente o Jg e εg. Os resultados mostraram que, com exceção da RPM, todos os circuitos investigados apresentaram baixos valores para os parâmetros de dispersão do ar. Taquari-Vassouras apresentou os mais baixos valores médios para Jg e εg, respectivamente, 0,05 cm/s e 5%. Os maiores valores de Jg foram determinados no circuito rougher da Copebras, 1,17 cm/s, ao passo que a RPM apresentou os maiores valores para o hold-up e tamanho de bolha, respectivamente, 31% e 2,61mm. Os valores obtidos, para Sb, situaram-se abaixo daqueles reportados na literatura.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Flow pumps act as important devices in areas such as Bioengineering, Medicine, and Pharmacy, among other areas of Engineering, mainly for delivering liquids or gases at small-scale and precision flow rate quantities. Principles for pumping fluids based on piezoelectric actuators have been widely studied, since they allow the construction of pump systems for displacement of small fluid volumes with low power consumption. This work studies valveless piezoelectric diaphragm pumps for flow generation, which uses a piezoelectric ceramic (PZT) as actuator to move a membrane (diaphragm) up and down as a piston. The direction of the flow is guaranteed by valveless configuration based on a nozzle-diffuser system that privileges the flow in just one pumping direction. Most research efforts on development of valveless flow pump deal either with computational simulations based on simplified models or with simplified physical approaches based on analytical models. The main objective of this work is the study of a methodology to develop a low-cost valveless piezoelectric diaphragm flow pump using computational simulations, parametric study, prototype manufacturing, and experimental characterization. The parametric study has shown that the eccentricity of PZT layer and metal layer plays a key role in the performance of the pump.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cefadroxil is a semi-synthetic first-generation oral cephalosporin used in the treatment of mild to moderate infections of the respiratory and urinary tracts, skin and soft tissue infections. In this work a simple, rapid, economic and sensitive HPLC-UV method is described for the quantitative determination of cefadroxil in human plasma samples using lamivudine as internal standard. Sample pre-treatment was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed with a mobile phase consisting of a mixture of sodium dihydrogen phosphate monohydrate solution, methanol and acetonitrile in the ratio of 90:8:2 (v/v/v) at a flow rate of 1.0mL/min. The proposed method is linear between 0.4 to 40.0 mu g/mL and its average recovery is 102.21% for cefadroxil and 97.94% for lamivudine. The method is simple, sensitive, reproducible, less time consuming for determination of cefadroxil in human plasma. The method can therefore be recommended for pharmacokinetics studies, including bioavailability and bioequivalence studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microparticles of ketoprofen entrapped in blends of acrylic resins (Eudragit RL 30D and RS 30D) were successfully produced by spray drying. The effects of the proportion ketoprofen : polymer (1: 1 and 1: 3) and of spray-drying parameters (drying gas inlet temperatures of 80 and 100 degrees C; microencapsulating composition feed flow rates of 4 and 6 g/min) on the microparticles properties (drug content, encapsulation efficiency, mean particle size, moisture content, and dissolution behavior) were evaluated. Differential scanning calorimetry (DSC) thermograms and X-ray diffractograms of the spray-dried product, the free drug, and the physical mixture between the free drug and spray-dried composition (blank) were carried out. Microparticles obtained at inlet temperature of 80 degrees C, feed flow rate of 4 g/min, and ketoprofen : acrylic resin ratio of 1: 3 presented an encapsulation efficiency of 88.1%, moisture content of 5.8%, production yield around 50%, and a higher reduction in dissolution rate of the entrapped ketoprofen. Sigmoidal shape dissolution profiles were presented by the spray-dried microparticles. The dissolution profiles were relatively well described by the Weibull model, a showing high coefficient of determination, R-2, and a mean absolute error between experimental and estimated values of between 4.6 and 10.1%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Diabetes causes changes in the salivary glands and in the composition of saliva, as well as symptoms such as dry mouth and hyposalivation. Therefore, this study aimed at investigating changes in salivary secretion and composition, in response to parasympathetic stimuli, in diabetic rats induced with streptozotocin. Design: Diabetes was induced by a single intraperitoneal injection of streptozotocin. Thirty days after diabetes induction, the animals were anaesthetized and salivation was stimulated by an intraperitoneal injection of Pilocarpine (0.6 mg/kg body weight) dissolved in distilled water. Saliva was collected for 40 min and immediately stored at -80 degrees C until analysis. The salivary flow rate, amount of total protein, amylase and peroxidase activities, and free and total sialic acid contents were measured. Results: Salivary flow rate was reduced in the diabetic group (p < 0.05). Moreover, increases in total protein amount and in amylase and peroxidase activities were observed in diabetic animals. No difference was observed for free sialic acid content between groups. On the other hand, a significantly decrease in the total sialic acid content was observed in the diabetic group (p < 0.05). Conclusions: Our findings suggest that a decrease in sialic acid in the saliva of diabetic animals can be related to xerostomia reported by diabetic patients. However, further clinical trials are needed to verify if the decrease in sialic acid also occurs in human saliva. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. To assess the efficacy and safety of intraprostatic injection of two botulinum neurotoxin type A (BoNT-A) doses for the treatment of benign prostatic hyperplasia (BPH). Materials and Methods. Men with symptomatic BPH who failed medical treatment were randomized to receive 100 U or 200 U of BoNT-A into the prostate. The International Prostatic Symptom Score (IPSS), maximum flow rate (Q(max)), post-void residual volume (PVR), PSA levels and prostate volume before injection and after 3 and 6 months were evaluated. Adverse events were compared between the groups. Results. Thirty four patients were evaluated, including 17 in the BoNT-A 100 U group and 17 in the BoNT-A 200 U group. Baseline characteristics were similar in both groups. Both doses produced significant improvements in IPSS, Q(max) and PVR after 3 and 6 months and both doses promoted comparable effects. Prostate volume was affected by 200 U BoNT-A injection only after 6 months of treatment. PSA levels were significantly affected in the 100 U group only after 6 months of treatment. In the 200 U group, PSA levels were significantly decreased after 3 and 6 months. The complication rate was similar in both groups. Conclusions. Efficacy and safety of both BoNT-A doses are similar for BPH treatment in the short term followup.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Active tufas in the form of waterfalls and dams occur along drainage channels in the Serra do Andre Lopes region (State of Sao Paulo, southeastern Brazil) and are associated with the karst system that developed on a dolomitic plateau with a superhumid subtropical climate. The predominance of autogenic waters enables the groundwater to become enriched in calcium carbonate, with low terrigenous sediment content. The tufas that were studied are composed of calcite and have high calcium contents and low magnesium contents. Eroded tufa beds that originate from changes in the position of fluvial channels or river flow rates also occur in this region. In the Sapatu deposit, phytohermal tufas with complex morphologies are arranged in levels constituting various temporally repeated sequences that were deposited between 10,570 and 4,972 cal years BP. In the Frias deposit, distal fluvial deposits of tufa are massive with a relatively greater quantity of terrigenous material and show evidence of dissolution and reprecipitation. The base of this deposit is composed of a cemented breccia dated at 25,390 years BP, which is younger than the overlying tufas ([42,000 years BP). In the two deposits, the levels of terrigenous sediments (quartz sand and lithic pebbles) and terrestrial gastropod shells are interpreted as phases of increased flow rate of rivers during intervals of higher rainfall.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The oil industry uses gas separators in production wells as the free gas present in the suction of the pump reduces the pumping efficiency and pump lifetime. Therefore, free gas is one of the most important variables in the design of pumping systems. However, in the literature there is little information on these separators. It is the case of the inverted-shroud gravitational gas separator. It has an annular geometry due to the installation of a cylindrical container in between the well casing and pioduction pipe (tubing). The purpose of the present study is to understand the phenomenology and behavior of inverted-shroud separator. Experimental tests were performed in a 10.5-m-length inclinable glass tube with air and water as working fluids. The water flow rate was in the range of 8.265-26.117 l/min and the average inlet air mass flow rate was 1.1041 kg/h, with inclination angles of 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees, 80 degrees and 85 degrees. One of the findings is that the length between the inner annular level and production pipe inlet is one of the most important design parameters and based on that a new criterion for total gas separation is proposed. We also found that the phenomenology of the studied separator is not directly dependent on the gas flow rate, but on the average velocity of the free surface flow generated inside the separator. Maps of efficiency of gas separation were plotted and showed that liquid flow rate, inclination angle and pressure difference between casing and production pipe outlet are the main variables related to the gas separation phenomenon. The new data can be used for the development of design tools aiming to the optimized project of the pumping system for oil production in directional wells. (C) 2012 Elsevier Inc. All rights reserved.