201 resultados para anterior segment length

em Queensland University of Technology - ePrints Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic Resonance Imaging was used to study changes in the crystalline lens and ciliary body with accommodation and aging. Monocular images were obtained in 15 young (19-29 years) and 15 older (60-70 years) emmetropes when viewing at far (6m) and at individual near points (14.5 to 20.9 cm) in the younger group. With accommodation, lens thickness increased (mean±95% CI: 0.33±0.06mm) by a similar magnitude to the decrease in anterior chamber depth (0.31±0.07mm) and equatorial diameter (0.32±0.04mm) with a decrease in the radius of curvature of the posterior lens surface (0.58±0.30mm). Anterior lens surface shape could not be determined due to the overlapping region with the iris. Ciliary ring diameter decreased (0.44±0.17mm) with no decrease in circumlental space or forward ciliary body movement. With aging, lens thickness increased (mean±95% CI: 0.97±0.24mm) similar in magnitude to the sum of the decrease in anterior chamber depth (0.45±0.21mm) and increase in anterior segment depth (0.52±0.23mm). Equatorial lens diameter increased (0.28±0.23mm) with no change in the posterior lens surface radius of curvature. Ciliary ring diameter decreased (0.57±0.41mm) with reduced circumlental space (0.43±0.15mm) and no forward ciliary body movement. Accommodative changes support the Helmholtz theory of accommodation including an increase in posterior lens surface curvature. Certain aspects of aging changes mimic accommodation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To examine whether anterior scleral and conjunctival thickness undergoes significant diurnal variation over a 24-hour period. Methods Nineteen healthy young adults (mean age 22 ± 2 years) with minimal refractive error (mean spherical equivalent refraction -0.08 ± 0.39 D), had measures of anterior scleral and conjunctival thickness collected using anterior segment optical coherence tomography (AS-OCT) at seven measurement sessions over a 24-hour period. The thickness of the temporal anterior sclera and conjunctiva were determined at 6 locations (each separated by 0.5 mm) at varying distances from the scleral spur for each subject at each measurement session. Results Both the anterior sclera and conjunctiva were found to undergo significant diurnal variations in thickness over a 24-hour period (both p <0.01). The sclera and conjunctiva exhibited a similar pattern of diurnal change, with a small magnitude thinning observed close to midday, and a larger magnitude thickening observed in the early morning immediately after waking. The amplitude of diurnal thickness change was larger in the conjunctiva (mean amplitude 69 ± 29 μm) compared to the sclera (21 ± 8 μm). The conjunctiva exhibited its smallest magnitude of change at the scleral spur location (mean amplitude 56 ± 17 μm) whereas the sclera exhibited its largest magnitude of change at this location (52 ± 21 μm). Conclusions This study provides the first evidence of diurnal variations occurring in the thickness of the anterior sclera and conjunctiva. Studies requiring precise measures of these anatomical layers should therefore take time of day into consideration. The majority of the observed changes occurred in the early morning immediately after waking and were of larger magnitude in the conjunctiva compared to the sclera. Thickness changes at other times of the day were of smaller magnitude and generally not statistically significant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

• The biomechanical properties of the sclera are documented to be altered in eyes with myopia, with the myopic sclera thought to be more susceptible to deformation from otherwise normal ocular forces. • The close anatomical and functional relationship between the ciliary body and sclera suggests that ciliary muscle contraction during accommodation may influence the overlying sclera. • This study aimed to characterise the changes occurring in anterior scleral thickness with accommodation using anterior segment optical coherence tomography (AS-OCT) in young adult myopes and emmetropes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In a previous chapter (Dean and Kavanagh, Chapter 37), the authors made a case for applying low intensity (LI) cognitive behaviour therapy (CBT) to people with serious mental illness (SMI). As in other populations, LI CBT interventions typically deal with circumscribed problems or behaviours. LI CBT retains an emphasis on self-management, has restricted content and segment length, and does not necessarily require extensive CBT training. In applying these interventions to SMI, adjustments may be needed to address cognitive and symptomatic difficulties often faced by these groups. What may take a single session in a less affected population may require several sessions or a thematic application of the strategy within case management. In some cases, the LI CBT may begin to appear more like a high-intensity (HI) intervention, albeit simple and with many LI CBT characteristics still retained. So, if goal setting were introduced in one or two sessions, it could clearly be seen as an LI intervention. When applied to several different situations and across many sessions, it may be indistinguishable from a simple HI treatment, even if it retains the same format and is effectively applied by a practitioner with limited CBT training. ----- ----- In some ways, LI CBT should be well suited to case management of patients with SMI. treating staff typically have heavy workloads, and find it difficult to apply time-consuming treatments (Singh et al. 2003). LI CBT may allow provision of support to greater numbers of service users, and allow staff to spend more time on those who need intensive and sustained support. However, the introduction of any change in practice has to address significant challenges, and LI CBT is no exception. ----- ----- Many of the issues that we face in applying LI CBT to routine case management in a mnetal health service and their potential solutions are essentially the same as in a range of other problem domains (Turner and Sanders 2006)- and, indeed, are similar to those in any adoption of innovation (Rogers 2003). Over the last 20 years, several commentators have described barriers to implementing evidence-based innovations in mental health services (Corrigan et al. 1992; Deane et al. 2006; Kavanagh et al. 1993). The aim of the current chapter is to present a cognitive behavioural conceptualisation of problems and potential solutions for dissemination of LI CBT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many people with severe mental illness (SMI) such as schizophrenia, whose psychotic symptoms are effectively managed, continue to experience significant functional problems. This chapter argues that low intensity (LI) cognitive behaviour therapy (CBT; e.g. for depression, anxiety, or other issues) is applicable to these clients, and that LI CBT can be consistent with long-term case management. However, adjustments to LI CBT strategies are often necessary and boundaries between LI CBT and high intensity (HI) CBT (with more extensive practitioner contact and complexity) may become blurred. Our focus is on LI CBT's self-management emphasis, its restricted content and segment length, and potential use after limited training. In addition to exploring these issues, it draws on the authors' Collaborative Recovery (CR; Oades et al. 2005) and 'Start Over and Survive' programs (Kavanagh et al. 2004) as examples. ----- ----- Evidence for the effectiveness of LI CBT with severe mental illness is often embedded within multicomponent programs. For example, goal setting and therapeutic homework are common components of such programs, but they can also be used as discrete LI CBT interventions. A review of 40 randomised controlled trials involving recipients with schizophrenia or other sever mental illnesses has identified key components of illness management programs (Mueser et al. 2002). However, it is relatively rare for specific components of these complex interventions to be assessed in isolation. Given these constraints, the evidence for specific LI CBT interventions with severe mental ilnness is relatively limited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Signal-degrading speckle is one factor that can reduce the quality of optical coherence tomography images. We demonstrate the use of a hierarchical model-based motion estimation processing scheme based on an affine-motion model to reduce speckle in optical coherence tomography imaging, by image registration and the averaging of multiple B-scans. The proposed technique is evaluated against other methods available in the literature. The results from a set of retinal images show the benefit of the proposed technique, which provides an improvement in signal-to-noise ratio of the square root of the number of averaged images, leading to clearer visual information in the averaged image. The benefits of the proposed technique are also explored in the case of ocular anterior segment imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To evaluate the use of optical coherence tomography (OCT) to assess the effect of different soft contact lenses on corneoscleral morphology. Methods. Ten subjects had anterior segment OCT B-scans taken in the morning and again after six hours of soft contact lens wear. For each subject, three different contact lenses were used in the right eye on non-consecutive days, including a hydrogel sphere, a silicone hydrogel sphere and a silicone hydrogel toric. After image registration and layer segmentation, analyses were performed of the first hyper-reflective layer (HRL), the epithelial basement membrane (EBL) and the epithelial thickness (HRL to EBL). A root mean square difference (RMSD) of the layer profiles and the thickness change between the morning and afternoon measurements, was used to assess the effect of the contact lens on the corneoscleral morphology. Results. The soft contact lenses had a statistically significant effect on the morphology of the anterior segment layers (p <0.001). The average amounts of change for the three lenses (average RMSD values) for the corneal region were lower (3.93±1.95 µm for the HRL and 4.02±2.14 µm for the EBL) than those measured in the limbal/scleral region (11.24±6.21 µm for the HRL and 12.61±6.42 µm for the EBL). Similarly, averaged across the three lenses, the RMSD in epithelial thickness was lower in the cornea (2.84±0.84 µm) than the limbal/scleral (5.47±1.71 µm) region. Post-hoc analysis showed that ocular surface changes were significantly smaller with the silicone hydrogel sphere lens than both the silicone hydrogel toric (p<0.005) and hydrogel sphere (p<0.02) for the combined HRL and EBL data. Conclusions. In this preliminary study, we have shown that soft contact lenses can produce small but significant changes in the morphology of the limbal/scleral region and that OCT technology is useful in assessing these changes. The clinical significance of these changes is yet to be determined.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

None of currently used tonometers produce estimated IOP values that are free of errors. Measurement incredibility arises from indirect measurement of corneal deformation and the fact that pressure calculations are based on population averaged parameters of anterior segment. Reliable IOP values are crucial for understanding and monitoring of number of eye pathologies e.g. glaucoma. We have combined high speed swept source OCT with air-puff chamber. System provides direct measurement of deformation of cornea and anterior surface of the lens. This paper describes in details the performance of air-puff ssOCT instrument. We present different approaches of data presentation and analysis. Changes in deformation amplitude appears to be good indicator of IOP changes. However, it seems that in order to provide accurate intraocular pressure values an additional information on corneal biomechanics is necessary. We believe that such information could be extracted from data provided by air-puff ssOCT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a clustering-only approach to the problem of speaker diarization to eliminate the need for the commonly employed and computationally expensive Viterbi segmentation and realignment stage. We use multiple linear segmentations of a recording and carry out complete-linkage clustering within each segmentation scenario to obtain a set of clustering decisions for each case. We then collect all clustering decisions, across all cases, to compute a pairwise vote between the segments and conduct complete-linkage clustering to cluster them at a resolution equal to the minimum segment length used in the linear segmentations. We use our proposed cluster-voting approach to carry out speaker diarization and linking across the SAIVT-BNEWS corpus of Australian broadcast news data. We compare our technique to an equivalent baseline system with Viterbi realignment and show that our approach can outperform the baseline technique with respect to the diarization error rate (DER) and attribution error rate (AER).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Crashes at any particular transport network location consist of a chain of events arising from a multitude of potential causes and/or contributing factors whose nature is likely to reflect geometric characteristics of the road, spatial effects of the surrounding environment, and human behavioural factors. It is postulated that these potential contributing factors do not arise from the same underlying risk process, and thus should be explicitly modelled and understood. The state of the practice in road safety network management applies a safety performance function that represents a single risk process to explain crash variability across network sites. This study aims to elucidate the importance of differentiating among various underlying risk processes contributing to the observed crash count at any particular network location. To demonstrate the principle of this theoretical and corresponding methodological approach, the study explores engineering (e.g. segment length, speed limit) and unobserved spatial factors (e.g. climatic factors, presence of schools) as two explicit sources of crash contributing factors. A Bayesian Latent Class (BLC) analysis is used to explore these two sources and to incorporate prior information about their contribution to crash occurrence. The methodology is applied to the state controlled roads in Queensland, Australia and the results are compared with the traditional Negative Binomial (NB) model. A comparison of goodness of fit measures indicates that the model with a double risk process outperforms the single risk process NB model, and thus indicating the need for further research to capture all the three crash generation processes into the SPFs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Subterranean clover stunt disease is an economically important aphid-borne virus disease affecting certain pasture and grain legumes in Australia. The virus associated with the disease, subterranean clover stunt virus (SCSV), was previously found to be representative of a new type of single-stranded DNA virus. Analysis of the virion DNA and restriction mapping of double-stranded cDNA synthesized from virion DNA suggested that SCSV has a segmented genome composed of 3 or 4 different species of circular ssDNA each of about 850-880 nucleotides. To further investigate the complexity of the SCSV genome, we have isolated the replicative form DNA from infected pea and from it prepared putative full-length clones representing the SCSV genome segments. Analysis of these clones by restriction mapping indicated that clones representing at least 4 distinct genomic segments were obtained. This method is thus suitable for generating an extensive genomic library of novel ssDNA viruses containing multiple genome segments such as SCSV and banana bunchy top virus. The N-terminal amino acid sequence and amino acid composition of the coat protein of SCSV were determined. Comparison of the amino acid sequence with partial DNA sequence data, and the distinctly different restriction maps obtained for the full-length clones suggested that only one of these clones contained the coat protein gene. The results confirmed that SCSV has a functionally divided genome composed of several distinct ssDNA circles each of about 1 kb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Anterior vertebral stapling using a nitinol staple is one such treatment. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The aims of this study were threefold; (1) to measure changes in the bending stiffness of a single motion segment following staple insertion, (2) to describe the forces that occur within the staple during spinal movement, and (3) to describe the anatomical changes that occur following staple insertion. Results suggest that staple insertion consistently decreased stiffness in all directions of motion. An explanation for the finding may be found in the outcomes of the strain gauge testing and micro-CT scan. The strain gauge testing showed that once inserted, the staple tips applied a baseline compressive force to the surrounding trabecular bone and vertebral end-plate. This finding would be consistent with the current belief that the clinical effect of the staples is via unilateral compression of the physis. Interestingly however, as each specimen progressed through the five cycles of each test, the baseline load on the staple tips gradually decreased, implying that the force at the staple tip-bone interface was decreasing. We believe that this was likely occurring as a result of structural damage to the trabecular bone and vertebral end-plate by the staple effectively causing ‘loosening’ of the staple. This hypothesis is further supported by the findings of the micro-CT scan. The pictures depict significant trabecular bone and physeal injury around the staple blades. These results suggest that the current hypothesis that stapling modulates growth through physeal compression may be incorrect, but rather the effect occurs through mechanical disruption of the vertebral growth plate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Currently the treatment options for idiopathic scoliosis are observation, bracing and fusion. While brace treatment is non-invasive, and preserves the growth, motion, and function of the spine, it does not correct deformity and is only modestly successful in preventing curve progression. In adolescents who fail brace treatment, surgical treatment with an instrumented spinal fusion usually results in better deformity correction but is associated with substantially greater risk. Furthermore in younger patients requiring surgical treatment, fusion procedures are known to adversely effect the future growth of the chest and spine. Fusionless treatments have been developed to allow effective surgical treatment of patients with idiopathic scoliosis who are too young for fusion procedures. Anterior vertebral stapling is one such fusionless treatment which aims to modulate the growth of vertebra to allow correction of scoliosis whilst maintaining normal spinal motion The Mater Misericordiae Hospital in Brisbane has begun to use anterior vertebral stapling to treat patients with idiopathic scoliosis who are too young for fusion procedures. Currently the only staple approved for clinical use is manufactured by Medtronic Sofamor Danek (Memphis, TN). This thesis explains the biomechanical and anatomical changes that occur following anterior vertebral staple insertion using in vitro experiments performed on an immature bovine model. Currently there is a paucity of published information about anterior vertebral stapling so it is hoped that this project will provide information that will aid in our understanding of the clinical effects of staple insertion. The aims of this experimental study were threefold. The first phase was designed to determine the changes in the bending stiffness of the spine following staple insertion. The second phase was designed to measure the forces experienced by the staple during spinal movements. The third and final phase of testing was designed to describe the structural changes that occur to a vertebra as a consequence of staple insertion. The first phase of testing utilised a displacement controlled testing robot to compare the change in stiffness of a single spinal motion segment following staple insertion for the three basic spinal motions of flexion-extension, lateral bending, and axial rotation. For the second phase of testing strain gauges were attached to staples and used to measure staple forces during spinal movement. In the third and final phase the staples were removed and a testing specimen underwent micro-computed tomography (CT) scanning to describe the anatomical changes that occur following staple insertion. The displacement controlled testing showed that there was a significant decrease in bending stiffness in flexion, extension, lateral bending away from the staple, and axial rotation away from the staple following staple insertion. The strain gauge measurements showed that the greatest staple forces occurred in flexion and the least in extension. In addition, a reduction in the baseline staple compressive force was seen with successive loading cycles. Micro-CT scanning demonstrated that significant damage to the vertebral body and endplate occurred as a consequence of staple insertion. The clinical implications of this study are significant. Based on the findings of this project it is likely that the clinical effect of the anterior vertebral staple evaluated in this project is a consequence of growth plate damage (also called hemiepiphysiodesis) causing a partial growth arrest of the vertebra rather than simply compression of the growth plate. The surgical creation of a unilateral growth arrest is a well established treatment used in the management of congenital scoliosis but has not previously been considered for use in idiopathic scoliosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the influence of accommodation upon axial length (and a comprehensive range of ocular biometric parameters), in populations of young adult myopic and emmetropic subjects. Methods: Forty young adult subjects had ocular biometry measured utilizing a non-contact optical biometer (Lenstar LS 900) based upon the principle of optical low coherence reflectometry, under three different accommodation demands (0 D, 3 D and 6 D). Subjects were classified as emmetropes (n=19) or myopes (n=21) based upon their spherical equivalent refraction (mean emmetropic refraction -0.05 ± 0.27DS and mean myopic refraction -1.82 ± 0.84 DS). Results: Axial length changed significantly with accommodation, with a mean increase of 11.9 ± 12.3 µm and 24.1 ± 22.7 µm for the 3 D and 6 D accommodation stimuli respectively. A significant axial elongation associated with accommodation was still evident even following correction of the axial length data for potential error due to lens thickness change. The mean ‘corrected’ increase in axial length was 5.2 ± 11.2 µm, and 7.4 ± 18.9 µm for the 3 D and 6 D stimuli respectively. There was no significant difference between the myopic and emmetropic populations in terms of the magnitude of change in axial length with accommodation, regardless of whether the data were corrected or not. A number of other ocular biometric parameters, such as anterior chamber depth, lens thickness and vitreous chamber depth also exhibited significant change with accommodation. The myopic and emmetropic populations also exhibited no significant difference in the magnitude of change in these parameters with accommodation. Conclusions: The eye undergoes a significant axial elongation associated with a brief period of accommodation, and the magnitude of this change in eye length increases for larger accommodation demands, however there is no significant difference in the magnitude of eye elongation in myopic and emmetropic subjects.