89 resultados para 110320 Radiology and Organ Imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: In 2013 QUT introduced the Medical Imaging Training Immersive Environment (MITIE) as a virtual reality (VR) platform that allowed students to practice general radiography. The system software has been expanded to now include C-Arm. The aim of this project was to investigate the use of this technology in the pedagogy of undergraduate medical imaging students who have limited to no experience in the use of the C-Arm clinically. Method: The Medical Imaging Training Immersive Environment (MITIE) application provides students with realistic and fully interactive 3D models of C-Arm equipment. As with VR initiatives in other health disciplines (1–2) the software mimics clinical practice as much as possible and uses 3D technology to enhance 3D spatial awareness and realism. The application allows students to set up and expose a virtual patient in a 3D environment as well as creating the resultant “image” for comparison with a gold standard. Automated feedback highlights ways for the student to improve their patient positioning, equipment setup or exposure factors. The students' equipment knowledge was tested using an on line assessment quiz and surveys provided information on the students' pre-clinical confidence scale, with post-clinical data comparisons. Ethical approval for the project was provided by the university ethics panel. Results: This study is currently under way and this paper will present analysis of initial student feedback relating to the perceived value of the application for confidence in a high risk environment (i.e. operating theatre) and related clinical skills development. Further in-depth evaluation is ongoing with full results to be presented. Conclusion: MITIE C-Arm has a development role to play in the pre-clinical skills training for Medical Radiation Science students. It will augment their theoretical understanding prior to their clinical experience. References 1. Bridge P, Appleyard R, Ward J, Phillips R, Beavis A. The development and evaluation of a virtual radiotherapy treatment machine using an immersive visualisation environment. Computers and Education 2007; 49(2): 481–494. 2. Gunn T, Berry C, Bridge P et al. 3D Virtual Radiography: Development and Initial Feedback. Paper presented at the 10th Annual Scientific Meeting of Medical Imaging and Radiation Therapy, March 2013 Hobart, Tasmania.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Undergraduate medical imaging students at an urban Australian university attend their first clinical placement towards the end of Semester two in their first year. While they often have a great deal of contextual knowledge and targeted theoretical learning prior to their first clinical placement, many of them are unfamiliar with the dynamics of a hospital environment. With the increase in online communication platforms, there was a concern that face-to-face clinical communication skills were becoming a source of anxiety for students, especially prior to their first clinical placements. Given the impact of anxiety on communication, reducing communication-related apprehension was considered a programme priority. A pilot series of scenario-based tutorials was implemented in the general radiography unit for the first year students.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In our complex and incongruous professional worlds, where there is no blueprint for dealing with unpredictable people and events, it is imperative that individuals develop reflexive approaches to professional identity building. Notwithstanding the importance of disciplinary knowledge and skills, higher education has a crucial role to play in guiding students to examine and mediate self in relation to context for effective decision-making and action. This paper reports on a small-scale longitudinal project that investigated the ways in which ten undergraduate students over the course of a three-year Radiation Therapy degree shaped their professional identities. Theories of reflexivity and methods of discourse analysis are utilised to understand the ways in which individuals accounted for their professional identity projects at university. The findings suggest that, across time, the participants negotiated professional ‘becoming’ through four distinct kinds of reflexive modalities. These findings have implications for teaching strategies and curriculum design in undergraduate programs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

- Background Sonography is an important diagnostic tool in children with suspected appendicitis. Reported accuracy and appendiceal visualisation rates vary significantly, as does the management of equivocal ultrasound findings. The aim of this study was to audit appendiceal sonography at a tertiary children's hospital, and provide baseline data for a future prospective study. - Summary of work Records of children who underwent ultrasound studies for possible appendicitis between January 2008 and December 2010 were reviewed. Variables included patient demographics, sonographic appendix characteristics, and secondary signs. Descriptive statistics and analysis using ANOVA, Mann-Whitney U test, and ROC curves were performed. Mater Human Research Ethic Committee approval was granted. - Summary of results There were 457 eligible children. Using a dichotomous diagnostic model (including equivocal results), sensitivity was 89.6%, specificity 91.6%, and diagnostic yield of 40.7%. ROC curve analysis of a 6mm diameter cut-off was 0.88 AUC (95% CI 0.80 to 0.95). - Discussion and conclusions Sonography is an accurate test for acute appendicitis in children, with a high sensitivity and negative predictive value. A diameter of 6mm as an absolute cut-off in a binary model can lead to false findings. Results were compared with available literature. Recent publications propose categorising diameter1 and integrating secondary signs2 to improve accuracy and provide more meaningful results to clinicians. This study will be a benchmark for future studies with multiple diagnostic categorisation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drawing on English language sources and material from Western Samoa (now Samoa), this examination of photographically illustrated serial encyclopaedia and magazines proposes an alternative historical analysis of the colonial photographs of Samoa, the most extensively covered field in Oceanic photographic studies. Photographs published between the 1890s and World War II were not necessarily from that era, and despite claims in the text of illustrated publications of an unchanged, enduring, archaic tradition in Samoa, the amazing variety of content and subject matter often offered contradictory evidence, depicting a modern, adaptive and progressive Samoa. Contrary to orthodox historical analysis, the images of Samoa in illustrated magazines and encyclopaedia were not limited to a small, repetitive gallery of partially clothed women and costumed chiefs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nationalism is not a naturally occurring sentiment, but rather needs to be carefully nurtured and sustained in the social imaginary through the production and circulation of unifying narratives that invoke the nation’s imagined community. The school curriculum is crucial in this process, legitimating and disseminating selected narratives while de-legitimating and marginalising other accounts and their voices. Certain watershed events in nations’ histories have always posed political problems in history curricula (Cajani & Ross, 2007) –however the pressures and concerns of current times now suggest political solutions in history curricula. This paper briefly examines recent political debates in Australia to argue that the school history curriculum has become a site of increasing interest for the exercise of official forms of nationalism and the production of a nostalgic, celebratory national biography. The public debates around school history curriculum are theorised as nostalgic re-nationalising efforts in response to the march of cultural globalisation and its attendant uncertainties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout history, developments in medicine have aimed to improve patient quality of life, and reduce the trauma associated with surgical treatment. Surgical access to internal organs and bodily structures has been traditionally via large incisions. Endoscopic surgery presents a technique for surgical access via small (1 Omm) incisions by utilising a scope and camera for visualisation of the operative site. Endoscopy presents enormous benefits for patients in terms of lower post operative discomfort, and reduced recovery and hospitalisation time. Since the first gall bladder extraction operation was performed in France in 1987, endoscopic surgery has been embraced by the international medical community. With the adoption of the new technique, new problems never previously encountered in open surgery, were revealed. One such problem is that the removal of large tissue specimens and organs is restricted by the small incision size. Instruments have been developed to address this problem however none of the devices provide a totally satisfactory solution. They have a number of critical weaknesses: -The size of the access incision has to be enlarged, thereby compromising the entire endoscopic approach to surgery. - The physical quality of the specimen extracted is very poor and is not suitable to conduct the necessary post operative pathological examinations. -The safety of both the patient and the physician is jeopardised. The problem of tissue and organ extraction at endoscopy is investigated and addressed. In addition to background information covering endoscopic surgery, this thesis describes the entire approach to the design problem, and the steps taken before arriving at the final solution. This thesis contributes to the body of knowledge associated with the development of endoscopic surgical instruments. A new product capable of extracting large tissue specimens and organs in endoscopy is the final outcome of the research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chief challenge facing persistent robotic navigation using vision sensors is the recognition of previously visited locations under different lighting and illumination conditions. The majority of successful approaches to outdoor robot navigation use active sensors such as LIDAR, but the associated weight and power draw of these systems makes them unsuitable for widespread deployment on mobile robots. In this paper we investigate methods to combine representations for visible and long-wave infrared (LWIR) thermal images with time information to combat the time-of-day-based limitations of each sensing modality. We calculate appearance-based match likelihoods using the state-of-the-art FAB-MAP [1] algorithm to analyse loop closure detection reliability across different times of day. We present preliminary results on a dataset of 10 successive traverses of a combined urban-parkland environment, recorded in 2-hour intervals from before dawn to after dusk. Improved location recognition throughout an entire day is demonstrated using the combined system compared with methods which use visible or thermal sensing alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cell migration is fundamental to many different physiological processes including embryonic development, inflammation and wound healing. Given the range and importance cell migration plays a number of assays have been developed to measure different aspects of cell migration. Here we describe two different methods to analyze cell migration. The first method analyzes the migration of fluorescently tagged cells using Boyden chambers and FACs and the second looks at migration properties using time-lapse microscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Contrast enhanced echocardiography (CEE) is utilised when sub-optimal image quality results in non-diagnostic echocardiograms. However, there have been numerous safety notices issued by regulatory authorities regarding rare but potentially serious adverse reactions (AR). This multi-centre, retrospective analysis was performed to assess the short-term safety of CEE in a broad range of indications. Methods All CEE performed over 58 months at three institutions were assessed for AR within 30 min. Results A total of 5956 CEE were performed in 5576 patients. A total of 4903 were stress CEE and 1053 resting CCE.Bolus administration in 5719, infusion in 237 cases; 89.9% of CCE were outpatients. Commonest CEE indication was functional stress testing (82.3%). There were 16 AR related to CEE (0.27%). All AR were mild, transient and all patients made a full recovery. No cases of serious anaphylaxis or death within 30 min of contrast administration. Comparing those with and without an AR, there were no significant differences in age, gender, BMI, LVEF, patient location, exam type or RVSP. There was a slightly increased likelihood of an AR during infusion versus bolus dosing (p = 0.02). Conclusion CEE is a safe investigation in a broad range of indications and clinical scenarios. AR are very rare, mild and transient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Long-term autonomy in robotics requires perception systems that are resilient to unusual but realistic conditions that will eventually occur during extended missions. For example, unmanned ground vehicles (UGVs) need to be capable of operating safely in adverse and low-visibility conditions, such as at night or in the presence of smoke. The key to a resilient UGV perception system lies in the use of multiple sensor modalities, e.g., operating at different frequencies of the electromagnetic spectrum, to compensate for the limitations of a single sensor type. In this paper, visual and infrared imaging are combined in a Visual-SLAM algorithm to achieve localization. We propose to evaluate the quality of data provided by each sensor modality prior to data combination. This evaluation is used to discard low-quality data, i.e., data most likely to induce large localization errors. In this way, perceptual failures are anticipated and mitigated. An extensive experimental evaluation is conducted on data sets collected with a UGV in a range of environments and adverse conditions, including the presence of smoke (obstructing the visual camera), fire, extreme heat (saturating the infrared camera), low-light conditions (dusk), and at night with sudden variations of artificial light. A total of 240 trajectory estimates are obtained using five different variations of data sources and data combination strategies in the localization method. In particular, the proposed approach for selective data combination is compared to methods using a single sensor type or combining both modalities without preselection. We show that the proposed framework allows for camera-based localization resilient to a large range of low-visibility conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies of semantic impairment arising from brain disease suggest that the anterior temporal lobes are critical for semantic abilities in humans; yet activation of these regions is rarely reported in functional imaging studies of healthy controls performing semantic tasks. Here, we combined neuropsychological and PET functional imaging data to show that when healthy subjects identify concepts at a specific level, the regions activated correspond to the site of maximal atrophy in patients with relatively pure semantic impairment. The stimuli were color photographs of common animals or vehicles, and the task was category verification at specific (e.g., robin), intermediate (e.g., bird), or general (e.g., animal) levels. Specific, relative to general, categorization activated the antero-lateral temporal cortices bilaterally, despite matching of these experimental conditions for difficulty. Critically, in patients with atrophy in precisely these areas, the most pronounced deficit was in the retrieval of specific semantic information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the significant shortcomings of the criminological canon, including its critical strands – feminist, cultural and green – has been its urbancentric bias. In this theoretical model, rural communities are idealised as conforming to the typical small-scale traditional societies based on cohesive organic forms of solidarity and close density acquaintance networks. This article challenges the myth that rural communities are relatively crime free places of ‘moral virtue’ with no need for a closer scrutiny of rural context, rural places, and rural peoples about crime and other social problems. This challenge is likewise woven into the conceptual and empirical narratives of the other articles in this Special Edition, which we argue constitute an important body of innovative work, not just for reinvigorating debates in rural criminology, but also critical criminology. For without a critical perspective of place, the realities of context are too easily overlooked. A new criminology of crime and place will help keep both critical criminology and rural criminology firmly anchored in the sociological and the criminological imagination. We argue that intersectionality, a framework that resists privileging any particular social structural category of analysis, but is cognisant of the power effects of colonialism, class, race and gender, can provide the theoretical scaffolding to further develop such a project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose This study evaluated the impact of a daily and weekly image-guided radiotherapy protocols in reducing setup errors and setting of appropriate margins in head and neck cancer patients. Materials and methods Interfraction and systematic shifts for the hypothetical day 1–3 plus weekly imaging were extrapolated from daily imaging data from 31 patients (964 cone beam computed tomography (CBCT) scans). In addition, residual setup errors were calculated by taking the average shifts in each direction for each patient based on the first three shifts and were presumed to represent systematic setup error. The clinical target volume (CTV) to planning target volume (PTV) margins were calculated using van Herk formula and analysed for each protocol. Results The mean interfraction shifts for daily imaging were 0·8, 0·3 and 0·5 mm in the S-I (superior-inferior), L-R (left-right) and A-P (anterior-posterior) direction, respectively. On the other hand the mean shifts for day 1–3 plus weekly imaging were 0·9, 1·8 and 0·5 mm in the S-I, L-R and A-P direction, respectively. The mean day 1–3 residual shifts were 1·5, 2·1 and 0·7 mm in the S-I, L-R and A-P direction, respectively. No significant difference was found in the mean setup error for the daily and hypothetical day 1–3 plus weekly protocol. However, the calculated CTV to PTV margins for the daily interfraction imaging data were 1·6, 3·8 and 1·4 mm in the S-I, L-R and A-P directions, respectively. Hypothetical day 1–3 plus weekly resulted in CTV–PTV margins of 5, 4·2 and 5 mm in the S-I, L-R and A-P direction. Conclusions The results of this study show that a daily CBCT protocol reduces setup errors and allows setup margin reduction in head and neck radiotherapy compared to a weekly imaging protocol.