123 resultados para test-taker feedback

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Careful study of various aspects presented in the note reveals basic fallacies in the concept and final conclusions.The Authors claim to have presented a new method of determining C-v. However, the note does not contain a new method. In fact, the method proposed is an attempt to generate settlement vs. time data using only two values of (t,8). The Authors have used a rectangular hyperbola method to determine C-v from the predicated 8- t data. In this context, the title of the paper itself is misleading and questionable. The Authors have compared C-v values predicated with measured values, both of them being the results of the rectangular hyperbola method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using Terzaghi's degree of consolidation, U, and the time factor, T, relationship, if M-U1 and M-U2 (M-U1 not equal M-U2) are slopes of the U-root T curve at any two time factors T-U1 and T-U2, then it can be shown that a unique relationship exists between T-U2/T-U1, M-U1/M-U2, and TU, (or TU2), and knowing any two of these, the third can be uniquely determined. A chart, called the T chart, has been plotted using these three variables for quickly determining T and U at any experimental time, t, to determine the coefficient of consolidation, c(v), corrected zero settlement, delta(o), and ultimate primary settlement, delta(100). The chart can be used even in those cases where settlement and time, at the instant of load increment, are not known.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taylor (1948) suggested the method for determination of the settlement, d, corresponding to 90% consolidation utilizing the characteristics of the degree of consolidation, U, versus the square root of the time factor, square root of T, plot. Based on the properties of the slope of U versus square root of T curve, a new method is proposed to determine d corresponding to any U above 70% consolidation for evaluation of the coefficient of consolidation, Cn. The effects of the secondary consolidation on the Cn value at different percentages of consolidation can be studied. Cn, closer to the field values, can be determined in less time as compared to Taylor's method. At any U in between 75 and 95% consolidation, Cn(U) due to the new method lies in between Taylor's Cn and Casagrande's Cn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The test based on comparison of the characteristic coefficients of the adjancency matrices of the corresponding graphs for detection of isomorphism in kinematic chains has been shown to fail in the case of two pairs of ten-link, simple-jointed chains, one pair corresponding to single-freedom chains and the other pair corresponding to three-freedom chains. An assessment of the merits and demerits of available methods for detection of isomorphism in graphs and kinematic chains is presented, keeping in view the suitability of the methods for use in computerized structural synthesis of kinematic chains. A new test based on the characteristic coefficients of the “degree” matrix of the corresponding graph is proposed for detection of isomorphism in kinematic chains. The new test is found to be successful in the case of a number of examples of graphs where the test based on characteristic coefficients of adjancency matrix fails. It has also been found to be successful in distinguishing the structures of all known simple-jointed kinematic chains in the categories of (a) single-freedom chains with up to 10 links, (b) two-freedom chains with up to 9 links and (c) three-freedom chains with up to 10 links.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combustion is a complex phenomena involving a multiplicity of variables. Some important variables measured in flame tests follow [1]. In order to characterize ignition, such related parameters as ignition time, ease of ignition, flash ignition temperature, and self-ignition temperature are measured. For studying the propagation of the flame, parameters such as distance burned or charred, area of flame spread, time of flame spread, burning rate, charred or melted area, and fire endurance are measured. Smoke characteristics are studied by determining such parameters as specific optical density, maximum specific optical density, time of occurrence of the densities, maximum rate of density increase, visual obscuration time, and smoke obscuration index. In addition to the above variables, there are a number of specific properties of the combustible system which could be measured. These are soot formation, toxicity of combustion gases, heat of combustion, dripping phenomena during the burning of thermoplastics, afterglow, flame intensity, fuel contribution, visual characteristics, limiting oxygen concentration (OI), products of pyrolysis and combustion, and so forth. A multitude of flammability tests measuring one or more of these properties have been developed [2]. Admittedly, no one small scale test is adequate to mimic or assess the performance of a plastic in a real fire situation. The conditions are much too complicated [3, 4]. Some conceptual problems associated with flammability testing of polymers have been reviewed [5, 6].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pollen of Parthenium hysterophorus, an alien weed growing wild in India was found to be a potential source of allergic rhinitis. A clinical survey showed that 34% of the patients suffering from rhinitis and 12% suffering from bronchial asthma gave positive skin-prick test reactions to Parthenium pollen antigen extracts. Parthenium-specific IgE was detected in the sera of sixteen out of twenty-four patients suffering from seasonal rhinitis. There was 66% correlation between skin test and RAST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salt-fog tests as per International Electrotechnical Commission (IEC) recommendations were conducted on stationtype insulators with large leakage lengths. Later, tests were conducted to simulate natural conditions. From these tests, it was understood that the pollution flashover would occur because of nonuniform pollution layers causing nonuniform voltage distribution during a natural drying-up period. The leakage current during test conditions was very small and the evidence was that the leakage current did not play any significant role in causing flashovers. In the light of the experimental results, some modification of the test procedure is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of laterally loaded piles is considerably influenced by the uncertainties in soil properties. Hence probabilistic models for assessment of allowable lateral load are necessary. Cone penetration test (CPT) data are often used to determine soil strength parameters, whereby the allowable lateral load of the pile is computed. In the present study, the maximum lateral displacement and moment of the pile are obtained based on the coefficient of subgrade reaction approach, considering the nonlinear soil behaviour in undrained clay. The coefficient of subgrade reaction is related to the undrained shear strength of soil, which can be obtained from CPT data. The soil medium is modelled as a one-dimensional random field along the depth, and it is described by the standard deviation and scale of fluctuation of the undrained shear strength of soil. Inherent soil variability, measurement uncertainty and transformation uncertainty are taken into consideration. The statistics of maximum lateral deflection and moment are obtained using the first-order, second-moment technique. Hasofer-Lind reliability indices for component and system failure criteria, based on the allowable lateral displacement and moment capacity of the pile section, are evaluated. The geotechnical database from the Konaseema site in India is used as a case example. It is shown that the reliability-based design approach for pile foundations, considering the spatial variability of soil, permits a rational choice of allowable lateral loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A frequency-domain positivity condition is derived for linear time-varying operators in2and is used to develop2stability criteria for linear and nonlinear feedback systems. These criteria permit the use of a very general class of operators in2with nonstationary kernels, as multipliers. More specific results are obtained by using a first-order differential operator with a time-varying coefficient as multiplier. Finally, by employing periodic multipliers, improved stability criteria are derived for the nonlinear damped Mathieu equation with a forcing function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A monostable multivibrator configuration using a new technique of regenerative feedback is discussed. This circuit provides an elegant alternative in situations wherein several monostable multivibrators have to be connected in tandem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Criteria for the L2-stability of linear and nonlinear time-varying feedback systems are given. These are conditions in the time domain involving the solution of certain associated matrix Riccati equations and permitting the use of a very general class of L2-operators as multipliers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a systematic method of investigating the existence of limit cycle oscillations in feedback systems with combined integral pulse frequency-pulse width (IPF-P/V) modulation. The method is based on the non-linear discrete equivalence of the continuous feedback system containing the IPF-PW modulator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A class of feedback systems, consisting of dynamical non-linear subsystems which arise in many diverse control applications, is analyzed for L2-stability. It is shown that, although a transformation of these systems to the familiar Lur'e configuration does not seem to be possible, a one-to-one correspondence may be effected between the stability properties of these and the Lur'e systems. Interesting stability criteria are developed by exploiting this characteristic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is concerned with the analysis of the absolute stability of a non-linear autonomous system which consists of a single non-linearity belonging to a particular class, in an otherwise linear feedback loop. It is motivated from the earlier Popovlike frequency-domain criteria using the ' multiplier ' eoncept and involves the construction of ' stability multipliers' with prescribed phase characteristics. A few computer-based methods by which this problem can be solved are indicated and it is shown that this constitutes a stop-by-step procedure for testing the stability properties of a given system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conditions under which the asymptotic stabilization of uniformly decoupled time-varying multivariate systems is possible are explored. This is accomplished by developing a canonical form for integrator uniformly decoupled system in which the coefficient matrices have a simple structure. The procedures developed rely on certain conditions on the given system and yield explicit expressions for the stabilization compensators.