157 resultados para Interferon-gamma


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human hepatoma and normal liver cells were irradiated with C-12(6+) ion beams (linear energy transfer (LET) = 96 keV mu m(-1)) and gamma-rays at the Heavy Ion Research Facility in Lanzhou (HIRFL). The numbers and types of chromatid breaks were detected using the premature chromosome condensation technique. Irradiation with C-12(6+) ions produced a majority of isochromatid break types, while chromatid breaks were dominant for irradiation with gamma-rays. Experimental results showed that the initial level of chromatid breaks is clearly related to the absorbed dose from C-12(6+), ions and gamma-rays. The (12)C(6+)ions are relatively more effective at inducing initial chromatid breaks when compared with the gamma-rays. A relative biological effectiveness (RBE) of about 2.5 resulted for the induction of initial chromatid breaks by C-12(6+) ions relative to gamma-rays in both cell lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypersensitive response of mammalian cells in cell killing to X- and gamma-rays has been reported at doses below 1 Gy. The purpose of this study was to examine the low dose sensitivity of human hepatoma SMMC-7721 cells irradiated with Co-60 gamma-rays and 50 MeV/u C-12 ions. Experiments using gamma-rays and charged particle irradiation were performed, particularly in the low dose range from 0 to 2 Gy. The survival effect of SMMC-7721 cells was measured by means of standard clonogenic assay in conjunction with a cell sorter. The result indicates SMMC-7721 cells showed hyper-radiosensitive response at low doses and increased radio-resistance at larger single doses for the carbon ions (LET = 45.2 keV/mu m) and the gamma-rays. However, the HRS/IRR effect caused by high-LET irradiation is different from that by low-LET radiation. This might possibly be due to the difference in the mode of energy deposition by particle beam and low-LET irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

探测器位置分辨能力的高低是实现γ成像的一个重要指标.Segmented HPGe平面型位置灵敏探测器能够很好地给出γ射线与探测器晶体相互作用的作用点位置信息.利用由这种探测器组成的探测器阵列对~(22)Na标准源进行了γ成像实验.结果能够区分出标准源两个不同的摆放位置的细微差别,并与实际情况符合得很好.从而检验了Segmented HPGe平面型位置灵敏探测器的位置分辨能力.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we investigate the rescattering effects in the radiative decay Gamma(5S) -> eta(b) + gamma , which were suggested to be crucially important for understanding the anomalous largeness of the branching ratios B(Gamma(5S) -> Gamma(1S) + pi pi) and B(Gamma(5S) -> Gamma(1S) + eta). Our calculations show that the rescattering effects may enhance Gamma(Gamma(10860) -> eta(b) +gamma) by four orders, but the tetraquark structure does not. Recently the BABAR and CLEO collaborations have measured the mass of eta(b) and the branching ratios B(Gamma(2S) -> eta(b) +gamma), B(Gamma(3S) -> eta(b) +gamma). We hope that very soon, Gamma(10860) -> eta(b) + gamma) will be measured and it would be an ideal opportunity for testing whether the rescattering or the tetraquark structure is responsible for the anomaly of B(Gamma(5S) -> Gamma(nS) pi(+) pi(-))(n = 1, 2, 3)), i. e., the future measurements on the radiative decays of Gamma(5S) might be a touchstone of the two mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The light-front quark model has been applied to calculate the transition matrix elements of heavy hadron decays. However, it is noted that using the traditional wave functions of the light-front quark model given in the literature, the theoretically determined decay constants of the Gamma(nS) obviously contradict the data. This implies that the wave functions must be modified. Keeping the orthogonality among the nS states and fitting their decay constants, we obtain a series of the wave functions for Gamma(nS). Based on these wave functions and by analogy with the hydrogen atom, we suggest a modified analytical form for the Gamma(nS) wave functions. Using the modified wave functions, the obtained decay constants are close to the experimental data. Then we calculate the rates of radiative decays of Gamma(nS) -> eta(b) + gamma. Our predictions are consistent with the experimental data on decays Gamma(3S) -> eta(b) + gamma within the theoretical and experimental errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a measurement of the gamma(1S + 2S + 3S) -> e(+)e(-) cross section at midrapidity in p + p collisions at root s = 200 GeV. We find the cross section to be 114 +/- 38(stat + fit)(-24)(+23)(syst) pb. Perturbative QCD calculations at next-to-leading order in the color evaporation model are in agreement with our measurement, while calculations in the color singlet model underestimate it by 2 sigma. Our result is consistent with the trend seen in world data as a function of the center-of-mass energy of the collision and extends the availability of gamma data to RHIC energies. The dielectron continuum in the invariant-mass range near the gamma is also studied to obtain a combined yield of e(+)e(-) pairs from the sum of the Drell-Yan process and b-(b) over bar production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inspired by the recent experimental data [J.-G. Wang, et al., Phys. Lett. B 675 (2009) 420], we extend the triaxial projected shell model approach to study the gamma-band structure in odd-mass nuclei. As a first application of the new development, the gamma-vibrational structure of Nb-103 is investigated. It is demonstrated that the model describes the ground-state band and multi-phonon gamma-vibrations quite satisfactorily, supporting the interpretation of the data as one of the few experimentally-known examples of simultaneous occurrence of one- and two-gamma-phonon vibrational bands. This generalizes the well-known concept of the surface gamma-oscillation in deformed nuclei built on the ground-state in even-even systems to gamma-bands based on quasiparticle configurations in odd-mass systems. (c) 2010 Elsevier BM. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high detection efficiency calorimeter which is used to detect gamma-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETIF) experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effects of gamma-ray radiation on the physiological, morphological characters and chromosome aberrations of minitubers. Materials and methods: Minitubers of one potato cultivar, 'Shepody', were irradiated with 8 doses of gamma-rays (0, 10, 20, 30, 40, 50, 60, 70 and 80 Gy [Gray]) to investigate the effects of radiation on emergence ability, plant height and root length, morphological variations, chromosome aberrations, M-1 (first generation mutants) tuber number and size of minituber plants. Results: Compared with the non-irradiated controls, the whole period of emergence was prolonged by 10-15 days for minitubers treated with gamma-ray radiation, but low doses of radiation (10, 20 and 30 Gy) promoted the emergence percentage of minitubers. With an increase in radiation dose, the emergence percentage, plant height and root length of minituber plants were significantly inhibited at 40 and 50 Gy. No emergence occurred at 60 Gy and higher doses. After radiation, a series of morphological variations and chromosome aberrations appeared in minituber plants. Radiation with 20 Gy promoted tuber formation, and the average number and diameter of M-1 tubers per plant were significantly increased over the control by 71% and 34%, respectively. Conclusion: Low doses of radiation (10-30 Gy) might be used as a valuable parameter to study the improvement of minitubers by gamma-ray radiation treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Coulomb dissociation of the proton-rich nuclei Cl-31 was studied experimentally using Cl-31 beams at 58 MeV/nucleon with a lead target. The relative energy between the reaction products, S-30 and proton, was obtained. The first excited state in Cl-31 was observed which is relevant to the resonant capture of stellar S-30(p, gamma)Cl-31 reaction

Relevância:

20.00% 20.00%

Publicador:

Resumo:

这篇论文里,我们对基于ms Windows的微机γ谱分析程序的数学原理,算法及程序设计进行了阐述;同时,我们也介绍了测试结果,此结果表明了拟合过程的高效性,高稳定性与准确性,并且,程序计算出的峰面积也是可接受的。 在第一部分里,全面阐述了数学原理与算法,包括由M. A. Mariscotti设计且已衍生出许多新算法的叫作DIFDIF的找峰算法,由BFGS方法实现的以χ2为拟合优值的拟合过程,在求峰下净面积及进行系统刻度中需要使用的公式等等。这些内客构成了γ谱分析程序设计哲学的核心,也是本论文的重点。 第二章里,我们一方面概括地介绍了基于面向对象思想的从系统分析到设计整个过程的系统开发文档;另一方面,我们也介绍了一些有用的程序片段,它们或者关于C++或MS Windows程序设计方法,或者关于运行时间错的处理。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The suitability of membrane cartridges for the removal of endotoxin from both distilled water and interferon preparations was examined. The endotoxin concentrations were reduced to 4.0 and 7.3 EU/ml, respectively, when about 4000 ml of distilled water with 20 and 28 EU/ml were passed through the deoxycholate and chitosan immobilized membrane cartridges. When 200 ml of interferon preparation with endotoxin concentration more than 80 EU/ml and pH 3.9 were applied to a deoxycholate immobilized membrane cartridge at a flow-rate of 9 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. However, if an interferon preparation of 450 ml, with more than 80 EU/ml of endotoxin and pH 3.9 was applied to the chitosan immobilized membrane cartridge at a flow-rate of 18 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-throughput screening is a promising new approach in analytical chemistry. Within the framework of an extended screening program (The German-Chinese Drug Screening Program), the enantioseparation of 86 drugs was investigated by capillary zone electrophoresis in the presence of the chiral solvating agent (CSA) octakis-(2,3,6-tri-O-methyl)-gamma-cyclodextrin (TM-gamma-CD). By this means, 15 drugs could be separated into enantiomeric pairs. Approximate measures for the degree of interaction (migration retardation factor, R-m) and for the degree of enantiomer recognition (migration separation factors, alpha(m)) revealed intriguing patterns that were compared with those found for native gamma-cyclodextrin (gamma-CD). Although there is a distinct influence of the analyte structure on the electrophoretic data, interpretation remains difficult. Most remarkably, permethylation of gamma-CD leads neither to a higher affinity nor to better chiral recognition, in contrast to the findings with alpha-CD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polybutadiene latex (PBL) vulcanization induced by Co-60 radiation and the influence of dose on crosslinking were investigated. Morphology and particle size distribution were examined by AFM and a particle size analyzer. The casting films were characterized for their swelling and mechanical properties as a function of dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of the concentration of a nucleating agent (NA), namely 1,3:2,4-di(3,4-dimethylbenzylidene) sorbitol (DMDBS), on the gamma phase content in a propylene/ethylene copolymer was investigated by means of Differential Scanning Calorimetry (DSC), Wide-Angle X-ray Diffraction (WAXD), Small- Angle X-ray Scatter (SAXS) and Polarized Optical Microscopy (POM).