53 resultados para counter immunoelectrophoresis

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cell culture and growth in space is crucial to understand the cellular responses under microgravity. The effects of microgravity were coupled with such environment restrictions as medium perfusion, in which the underlying mechanism has been poorly understood. In the present work, a customer-made counter sheet-flow sandwich cell culture device was developed upon a biomechanical concept from fish gill breathing. The sandwich culture unit consists of two side chambers where the medium flow is counter-directional, a central chamber where the cells are cultured, and two porous polycarbonate membranes between side and central chambers. Flow dynamics analysis revealed the symmetrical velocity profile and uniform low shear rate distribution of flowing medium inside the central culture chamber, which promotes sufficient mass transport and nutrient supply for mammalian cell growth. An on-orbit experiment performed on a recovery satellite was used to validate the availability of the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endogenous retroviruses ( ERVs) are remnants of ancient retroviral infections of the host germline transmitted vertically from generation to generation. It is hypothesized that some ERVs are used by the host as restriction factors to block the infection o

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of counter-ions on the coagulation of biologically treated molasses wastewater using iron-based coagulants was investigated. Parameters such as removals of chemical oxygen demand (COD) and color, and residual turbidity, were measured to evaluate coagulation performance. Experimental results showed that ferric chloride and ferric nitrate were more effective than ferric sulfate at optimal dosages, achieving 89 to 90% and 98 to 99% of COD and color removals, respectively, with residual turbidity of less than 5 NTU. High-performance size exclusion chromatography (HPSEC) results revealed differences in the removal of the molecular weight fraction of organic compounds using iron salts. Scanning electron microscopy (SEM) showed randomly formed coagulated flocs characterized with irregular, sheet-like shapes. Nitrate and chloride counter-ions had similar effects on coagulation performance compared to sulfate. Both FeCl3 and Fe(NO3)(3) yielded better results than Fe(SO4)(2) under underdosed and optimum dosage conditions. Coagulation efficiency was less adversely affected in the overdosed regions, however, if sulfate rather than chloride or nitrate was present. Water Environ. Res., 81, 2293 (2009).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present multi- frequency radio observational results of the quasar 3C 48. The observations were carried out with the Very Large Array ( VLA) at five frequencies, 0.33, 1.5, 4.8, 8.4, and 22.5 GHz, and with the Multi- Element Radio Linked Interferometer Network ( MERLIN) at the two frequencies of 1.6 and 5 GHz. The source shows a one- sided jet to the north within 1", which then extends to the northeast and becomes diffuse. Two bright components ( N2 and N3), containing most of the flux density, are present in the northern jet. The spectral index of the two components is alpha(N2) similar to -0.99 +/- 0.12 and alpha(N3) similar to - 0.84 +/- 0.23 ( S proportional to nu(alpha)). Our images show the presence of an extended structure surrounding component N2, suggestive of strong interaction between the jet and the interstellar medium ( ISM) of the host galaxy. A steep- spectrum component, labelled S, located 0.25 " southwest to the flat- spectrum component which could be the core of 3C 48, is detected at a significance of > 15 sigma. Both the location and the steepness of the spectrum of component S suggest the presence of a counter- jet in 3C 48.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator af...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In present paper, a new Micromegas detector is developed, and its time and energy signals are obtained in the figure form. The rising time of fast time signal is less than 2 ns due to the very fast collection of avalanche electrons, and the rising time of the energy pulse is about 100 ns, which is corresponding to the total collecting time of the electrons and ions in the avalanche process. The counter plateau, energy resolution and the gas gains of the detector have been compared with other groups' experimental results and the Garfield simulation result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review covers the discovery and studies of the year-round northeastward currents off the southeastern China coast, paying special attention to its upwind characteristic in winter, mainly focusing on work by Chinese oceanographers. This current system is a prominent and unique phenomenon in the shelf circulation of the world ocean. The general features of the current system are summarized. The evidence for the existence and the variation of the three parts of the currents-the South China Sea Warm Current, the Taiwan Strait Warm Current and the Taiwan Warm Current-are separately elucidated. The formation mechanisms of the current as a whole are explained using dynamic analysis and numerical simulation results. Some suggestions for further studies are also made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supercritical fluid extraction (SFE) was used to extract homoisoflavonoids from Ophiopogon japonicus (Thunb.) Ker-Gawler. The optimization of parameters was carried out using an orthogonal test L-9 (3)(4) including pressure, temperature, dynamic extraction time and the amount of modifier. The process was then scaled up by 100 times with a preparative SFE system under the optimized conditions of 25 MPa, 55 degrees C, 4.0 h and 25% methanol as a modifier. Then crude extracts were separated and purified by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane/ethyl acetate/methanol/ACN/water (1.8:1.0:1.0:1.2:1.0 v/v). There three homoisoflavonoidal compounds including methylophiopogonanone A 6-aldehydo-isoophiopogonone A, and 6-formyl-isoophiopogonanone A, were successfully isolated and purified in one step. The collected fractions were analyzed by HPLC. In each operation, 140 mg crude extracts was separated and yielded 15.3 mg of methylophiopogonanone A (96.9% purity), 4.1 mg of 6-aldehydo-isoophiopogonone A (98.3% purity) and 13.5 mg of 6-formyl-isoophiopogonanone A (97.3% purity) respectively. The chemical structure of the three homoisoflavonoids are identified by means of ESI-MS and NMR analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-speed counter-current chromatography (HSCCC) technique in semi-preparative scale has been successfully applied to the separation of bioactive flavonoid compounds, liquiritigenin and isoliquiritigenin in one step from the crude extract of Glycyrrhiza uralensis Risch. The HSCCC was performed using a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-acetonitrile-water (2:2:1:0.6:2, v/v). Yields of liquiritigenin (98.9% purity) and isoliquiritigenin (98.3% purity) obtained were 0.52% and 0.32%. Chemical structures of the purified liquiritigenin and isoliquiritigenin were identified by electrospray ionization-MS (ESI-MS) and NMR analysis. (c) 2005 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The melt flow and temperature distribution in a 200 mm silicon Czochralski furnace with a cusp magnetic field was modeled and simulated by using a finite-volume based FLUTRAPP ( Fluid Flow and Transport Phenomena Program) code. The melt flow in the crucible was focused, which is a result of the competition of buoyancy, the centrifugal forces caused by the rotations of the crucible and crystal, the thermocapillary force on the free surfaces and the Lorentz force induced by the cusp magnetic field. The zonal method for radiative heat transfer was used in the growth chamber, which was confined by the crystal surface, melt surface, crucible, heat shield, and pull chamber. It was found that the cusp magnetic field could strength the dominant counter-rotating swirling flow cell in the crucible and reduce the flow oscillation and the pulling-rate fluctuation. The fluctuation of dopant and oxygen concentration in the growing crystal could thus be smoothed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

对超声速反向射流混合加热方案进行实验验证。实验结果表明:控制向燃烧室注入水雾的流量可以方便地调节燃烧室的温度和压力;用双路氢氧进气系统易于实现稳定的点火和燃烧。用热电偶测量混合前后的流场温度分布的初步结果表明,反向射流混合方案基本可行。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

研制成功便携式激光尘埃粒子计数器的核心部件——微型光学传感器。该传感器采用直角散射光收集形式。以高功率半导体激光器作为光源,同时采用高性能的PIN型光电二极管作为光电探测器。散射光收集系统为单一大数值孔径的球面反射镜,其对粒子散射光的收集角范围从20°到160°。粒子散射光信号是脉冲信号,其频谱成份主要在高频段,所以在PIN型光电二极管后用一个带通式前置放大器来消除外界的低频噪声.根据米氏散射理论计算了该光学传感器的光散射响应特性,并用聚苯乙烯标准粒子实测了该光学传感器的性能。结果表明,该系统具有高的信噪

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在Mie散射理论基础上,由单分散射的光强表达式导出在偏振光的入射条件下一定立体角内的散射光通量的表达式,并与自然光入射作比较。计算了在相同强度不同光源入射下,尘埃粒子计数器的两种常用散射光收集系统收集的散射光通量。结果表明:采用近前向散射光收集系统得到的光通量相等;而采用直角方向散射光收集系统时两者并不相等,且在平面偏振光入射时,收集的散射光通量还跟探测器中心与入射光偏振方向夹角有关。用MATLAB编程计算,得出了在探测器中心与偏振方向的夹角成90°或270°位置时,收集的散射光通量有极值的结论,为激光尘

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electric fields inside guided-mode resonance filters (GMRFs) may be intensified by resonance effects. The electric field enhancement is investigated in two GMRFs: one is resonant at normal incidence, the other at oblique incidence. It is shown that the two GMRFs exhibit different behaviors in their electric enhancement. Differences between the electric field distributions of the two GMRFs arise because coupling between counter-propagating modes occurs in the first case. It is also shown that the order of the electric field of maximum amplitude can be controlled by modulation of the dielectric constant of the grating. (c) 2006 Optical Society of America.