98 resultados para High resolution gas chromatography - mass spectrometry

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive, and accurate method for determination of polybrominated diphenyl ethers (PBDEs) in soil has been developed based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). Permethylated-beta-cyclodextrin/hydroxyl-termination silicone oil (PM-beta-CD/OH-TSO) fiber was first prepared by sol-gel technology and employed in SPME procedure. By exploiting the superiorities of sot-gel coating technique and the advantages of the high hydrophobic doughnut-shaped cavity of PM-beta-CD, the novel fiber showed desirable operational stability and extraction ability. After optimization on extraction conditions like water addition, extraction temperature, extraction time, salts effect, and solvents addition, the method was validated in soil samples, achieving good linearity (r>0.999), precision (R.S.D. < 10%), accuracy (recovery>78%), and detection limits (S/N =3) raging from 13.0 to 78.3 pg/g. (c) 2007 Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three major odorous compounds are 2-methylisoborneol ( 2-MIB), geosmin and beta-cyclocitral, which in water were determined by coupling headspace solid-phase microextraction ( HS-SPME) with gas chromatography-mass spectrometry (GC-MS). The operating conditions of HS-SPME, such as fibre type, salt concentration, water temperature, stirring, absorption time and desorption time were studied and discussed.The highest absorption of the odorous compounds were obtained under the following operating conditions as the addition of 30% ( m/V) NaCl, stirring at 60 degrees C for 40 min, using 65 mu m polydimethyl siloxane/divinylbenzene coated fibre. After the odorous compounds had been absorbed in the fibre under the optimal conditions of HSSPME, they were desorbed at 250 degrees C and determined by GC-MS. The limits of detection for geosmin, beta-cyclocitral and 2-MIB in water were 1. 0, 1. 3, 1. 7 ng/L, and the relative standard deviations for them were 4. 9%, 8. 4%, 6. 2%,respectively. There were good linear correlation (the calibration coefficients were all above 0. 997) for the three odorous compounds in the range of 5 similar to 1000 ng/ L. Therefore, trace levels of the odorous compounds at ng/L in water could be quantified by the simple method with satisfactory result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas chromatography-mass spectrometry with electron ionization and positive-ion chemical ionization and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOF-MS) were applied for the characterization of the chemical composition of complex hydrocarbons in the non-polar neutral fraction of cigarette smoke condensates. Automated data processing by TOF-MS software combined with structured chromatograms and manual review of library hits were used to assign the components from GC x GC-TOF-MS analysis. The distributions of aliphatic hydrocarbons and aromatics were also investigated. Over 100 isoprenoid hydrocarbons were detected, including carotene degradation products, phytadiene isomers and carbocyclic diterpenoids. A total of 1800 hydrocarbons were tentatively identified, including aliphatic hydrocarbons, aromatics, and isoprenoid hydrocarbons. The identified hydrocarbons by GC x GC-TOF-MS were far more than those by GC-MS. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high performance liquid chroatography-electrospray ionization-mass spectrometric method was developed for analysis and identification of ginsenosides from the decoction of ginseng, ginseng with trogopteroum feces and ginseng with semen raphani. Ten ginsenosides were separated and detected. The content variation of these ginsenosides was researched. The experimental results showed, that ginsenosides were less in compatible decoction than in separate one expect Ro. the stripping of ginsenosides were restrained by semen raphani and during combination of ginseng with trogopteroum feces, the precipitates were produced by ginsenosides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The essential oil in purple magnolia leaves was extracted by steam distillation approaches. The oil obtained was dried with anhydrous magnesium sulfate. According to the analysis of gas chromatography/mass spectrometry, more than 40 peaks were separated and 32 compounds were identified. The identified constituents represent 95% of the peak area of the essential oil. The main compounds were germacrene-D, santolina triene, caryophyllene, 1,3,7-octatriene, 3,7-dimethyl, and camphene, etc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GUMS)and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC x GC/TOFMS), respectively. In the GUMS analysis, serially coupled columns were used. By comparing the GUMS results with GC x GC/TOFMS result,,, many more components in the essential oil could be found within the two-dimensional separation space of GC x GC. The quantitative determination of components in the essential oil was performed by GC x GC with flame ionization detection (FID), using a method of multiple internal standards calibration, (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A quantitative analysis of the individual compounds in tobacco essential oils is performed by comprehensive two-dimensional gas chromatography (GC x GC) combined with flame ionization detector (FID). A time-of-flight mass spectrometer (TOF/MS) was coupled to GC x GC for the identification of the resolved peaks. The response of a flame ionization detector to different compound classes was calibrated using multiple internal standards. In total, 172 compounds were identified with good match and 61 compounds with high probability value were reliably quantified. For comparative purposes, the essential oil sample was also quantified by one-dimensional gas chromatography-mass spectrometry (GC/MS) with multiple internal standards method. The results showed that there was close agreement between the two analysis methods when the peak purity and match quality in one-dimensional GC/MS are high enough. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A macro matrix solid-phase dispersion (MSPD) method was developed to extract 266 pesticides from apple juice samples prior to gas chromatography-mass selective detection (GC-MSD) determination. A 10 g samples was mixed with 20 g diatomaceous earth. The mixture was transferred into a glass column. Pesticide residues were leached with a 160 mL hexane-dichloromethane (1:1) at 5 mL/min. Two hundred and sixty-six pesticides were divided into three groups and detected by GC-MSD under selective ion monitoring. The proposed method takes advantage of both liquid-liquid extraction and conventional MSPD methods. Application was illustrated by the analysis of 236 apple juice samples produced in Shaanxi province China mainland this year. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On a reversed phase Hypersil BDS C-18 (200 mm x 4. 6 mm, 5 mu m) column, 20 amino acids, which were derivatized using 2-(11H-benzo [a] carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) as pre-column derivatization reagent, were separated in conjunction with a gradient elution. Optimum derivatization was obtained by reacting of amino acids with BCEC-Cl at room temperature for 5 min in the presence of sodium borate catalyst in acetonitrile solvent. The fluorescence excitation and emission wavelengths were 279 nm and 380 nm respectively. The identification of amino acid derivatives from hydrolyzed bovine serum albumin and bee pollen was carried out by post-column mass spectrometry with electrospray ion source in positive ion mode. Linear correlation coefficients of the amino acid derivatives were > 0.9990, and detection limits (at signal to noise of 3:1) were 1.49 - 19.74 fmol for the labeled amino acids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aryl hydrocarbon (Ah) receptor (Ah-agonist) effects of environmental samples containing polychlorinated aromatic hydrocarbons were evaluated using a 7-ethoxyresorufin-O-deethylase (FROD) assay of a primary hepatocyte culture from grass carp (Ctenopharyngodon idellus). The results were compared with those obtained from the assay using the rat hepatoma cell line H4IIE and chemical analysis using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). A dose-response relationship was observed between the EROD activities, either from primary hepatocyte culture assay or from H4IIE assay, and concentrations of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). The results showed that the assay based on the H4IIE cell line (EC50 = 0.83 mug/mL) is more sensitive to TCDD than the assay based on primary hepatocyte Culture (EC50 = 9.7 pg/mL). In tests of environmental samples, the results from the assay using primary hepatocyte culture were comparable to those from the assay using the H4IIE cell line and chemical analysis of concentrations of mixtures of polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF). The lack of a change in the activities of glutathione-S-transferase (GST) and lactate dehydrogenase (LDH) in cell culture upon exposure to TCDD indirectly indicates that the compound is persistent to biodegradation in the cell culture system. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By using modern techniques of isotope dilution, high-resolution gas chromatography/high-resolution mass spectrometry and multiple ions detection, an effective cleanup, qualitative and quantitative method was developed for polychlorinated dibenzo-p-dioxins/furans (PCDD/F) and polychlorinated biphenyls analysis. Based on the chromatographic relative retentions of PCDD/F, a software was established for automatic peak recognition of all the isomers from tetra- to octachlorine PCDD/F. It ensured good reliability and accuracy of the analytical data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A software has been developed for the peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) after high resolution gas chromatography coupled with mass spectrometry (HRGC/HRMS). Based on the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retention times of all PCDD and PCDF can be calibrated automatically and accurately. Therefore, it is very convenient to identify the peaks by comparing the retention of samples and the calibrated retention times of their chromatograms. Hence, this approach is very significant because it is impossible to obtain always a standard chromatogram and PCDD/F analysis are very expensive and time consuming. The calibration results can be transferred to Excel for calculation. The approach is a first step to store costly and environmentally relevant data for future application.