An Approach to the Rehabilitation of Prelingually Deaf Children After Cochlear Implantation Zheng Xiujin(Medical Psychology) Directed by Professor Yin WenGang Abstract Objective: To sum up the acquirement rule of speech and language capability which is for the prelingually deaf children after cochlear implantation by listening and language rehabilitation training and to investigate the factors that affect rehabilitation speed. Method: Sixty-four children received a cochlear implant at the age of 2 to 5 years from 2001 to 2005. They begin to be trained under group pattern after switch on 1 month. The whole training program lasted more than 7 months; after that, according to the teacher’s plan the training program was to be continued at home. Result: The period is 108±7.7 days that they can pronounce correctly 50 percent of all of simple-finals and compound-finals, the period is 115.0±7.8 days that they begin auditory repeating, the period is 135.3±10.9 days that they can speech the first specific word independently and the period is 200.3±13.9 days that they can speak 70 words and come into tri-gamut-word and two-word sentence period. The patient that is the group at the age of 2-3 years can take part in normal kindergarten after switch on about 10 months. There are no significant differences in various grades of speech-language development with different age groups and so do with different sex groups. There are significant differences in various grade of speech-language development with various IQ group (P<0.01) and so do with using and not using hearing aids before implantation. Conclusion: From the research we find that the speech and language development sequence is the same level between the prelingually deaf children of 2 to 5 years who received cochlear implant after speech training and normal children and which are stages of uncomplicated sound production, continuous syllabic (babbling), speech sprout, single-word utterances and two-word utterances in proper order. The time is short significantly and the reason is that cognition capability is enhanced along with the increase of age. The intelligence is main factor that affect rehabilitation speed and the speed in the group of high IQ is faster than common IQ. It is not because of the dominance cognition of the senior group that makes the increasing of the rehabilitation, it even makes slowly. The reason of which is that the senior group are exposed the language environment too late to achieve speech and language development. So we should perform an operation and training early. The effectiveness of rehabilitation after cochlear implantation is improved by using hearing aids before implantation. The reason is auditory stimulate can be benefit of to deaf children. The rehabilitation speeds in the children at the age of 2 to 5 years have nothing to do with sex. Key words: cochlear implant; speech therapy; paediatric rehabilitation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Subretinal microphotodiode array (MPDA) is a type of visual prosthesis used for the implantation in the subretinal space of patients with progressive photoreceptor cell loss. The present study aimed to evaluate the effect of materials for MPDA on the viability, apoptosis and barrier function of cultured pig retinal pigment epithelium (RPE) cells.Methods: Primary culture of pig RPE cells was performed and 24 pig eyes were used to start RPE culture. The third passage of the cultures was plated on different materials for MPDA and MPDAs. The tetrazolium dye-reduction assay (MTT) was used to determine RPE cell viability. Flow cytometry was measured to indicate the apoptosis rates of RPE cells on different materials. RPE cells were also cultured on microporous filters, and the transepithelial resistance and permeability of the experimental molecule were measured to determine the barrier function.Results: The data from all the methods indicated no significant difference between the materials groups and the control group, and the materials tested showed good biocompatibility.Conclusions: The materials for MPDA used in the present study had no direct toxicity to the RPE cells and did not release harmful soluble factors that affected the barrier function of RPE in vitro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermally stable high-resistivity regions have been formed using hydrogen ion implantation at three energies (50, 100, and 180 keV) with three corresponding doses (6 X 10(14) 1.2 X 10(15), and 3 X 10(15) cm(-2)), oxygen implantation at 280keV with 2 X 10(14) cm(-2) as well as subsequent annealing at about 600 degrees C for 10-20s, in AlGaAs/GaAs multiple epitaxial heterojunction structure. After anncaling at 600 degrees C, the sheet resistivity increases by six orders more of magnitude from the as-grown values. This creation of high resistivity is different from that of the conventional damage induced isolation by H or O single implantation which becomes ineffective when anneal is carried out at 400-600 degrees C and the mechanism there of is discussed.