69 resultados para Capsid proteins


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the antioxidant activity of proteins isolated from jellyfish, Rhopilema esculentum Kishinouye (R. esculentum), was determined by various antioxidant assays, including superoxide anion radical-scavenging, hydroxyl radical-scavenging, total antioxidant activity, reducing power and metal chelating activity. Butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), alpha-tocopherol, vitamin C and mannitol were used as standards in those various antioxidant activities. The crude protein (CP) and the protein fractions isolated by Sephadex chromatography, first peak (FP) and second peak (SP), had very low reductive power and metal chelating abilities compared to EDTA, but they showed strong scavenging effects on the superoxide anion radical, hydroxyl radical and varying total antioxidant activity. FP and SP exhibited stronger scavenging effects on the superoxide anion radical than BHA, BHT or a-tocopherol. The EC50 values of FP and SP were 6.12 and 0.88 mu g/ml, respectively, while values EC50 of BHA, BHT and alpha-tocopherol were 31, 61 and 88 mu g/ml, respectively. CP, FP and SP showed far higher hydroxyl radical-scavenging activities than did vitamin C or mannitol. The EC50 values of CP, FP and SP were 48.76, 45.42 and 1.52 mu g/ml, but EC50 values of vitamin C and mannitol were 1907 and 4536 mu g/ml, respectively. In a beta-carotene-linoleate system, SP and CP showed antioxidant activity, but lower than BHA. Of the three samples, SP had the strongest antioxidant activity. So, SP may have a use as a possible supplement in the food and pharmaceutical industries. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new program to characterize polyethylene glycol-modified (PEGylated) proteins is outlined using capillary zone electrophoresis (CZE). PEGylated ribonuclease A and lysozyme were selected as examples. Five separation procedures were compared to select out the mixed buffer of acetonitrile-water (1:1, v/v) at pH 2.5 as the best to characterize the PEGylated proteins without sample pretreatment. Polyethylene oxide (PEO) with a high molecular mass of 8X10(6) was applied to rinse the capillary to form a dynamic coating which would decrease the undesirable proteins adsorbed to the inner wall of the silica. The electroosmotic flow (EOF) mobility of the five procedures was determined, respectively. It is found that acetonitrile is mainly responsible for the good resolution of PEGylated proteins with the help of PEO coating in the semi-aqueous system. The low EOF mobility and current in the semi-aqueous system might also have some responsibility for the high resolution. The semi-aqueous procedure described in this paper also demonstrates higher resolution of natural proteins than aqueous ones. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new set-up was constructed for capillary isoelectric focusing (CIEF) involving a sampling capillary as a bypass fixed to the separation capillary. Sample solutions were subjected to a previously established pH gradient from the sample capillary. Besides performing conventional CIEF, the separation of ampholytic compounds with isoelectric points (p/s) beyond the pH gradient was carried out on this system. This method was termed as pH gradient driven electrophoresis (PGDE) and the basic mathematical expressions were derived to express the dynamic fundamentals. Proteins such as lysozyme, cytochrome C, and pepsin with p/s higher than 10 or below 3 were separated in a pH gradient provided by Pharmalyte (pH 3-10). Finally, this protocol convincingly exhibited its potential in the separation of a solution of chicken egg white.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressurized capillary electrochromatography (pCEC) and electrospray ionization-mass spectrometry (ESI-MS) have been hyphenated for protein analysis. Taken cytochrome c, lysozyme, and insulin as samples, the limits of detection (LODs) for absolute concentrations are 10(-11) mol (signal-to-noise ratio S/N = 3) with relative standard deviations (RSDs) of retention time and peak area, respectively, of less than 1.7% and 4.8%. In order to improve the detection sensitivity, on-line concentration by field-enhanced sample-stacking effect and chromatographic zone-sharpening effect has been developed, and parameters affecting separation and detection, such as pH and electrolyte concentration in the mobile phase, separation voltage, as well as enrichment voltage and time, have been studied systematically. Under the optimized conditions, the LODs of the three proteins could be decreased up to 100-fold. In addition, the feasibility of such techniques has been further demonstrated by the analysis of modified insulins at a concentration of 20 mu g/mL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An iminodiacetic acid (IDA)-type adsorbent is prepared at the one end of a capillary by covalently bonding IDA to the monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate). Cu(II) is later introduced to the support via the interaction with IDA. By this means, polymer monolithic immobilized metal affinity chromatography (IMAC) materials are prepared. With such a column, IMAC for on-line concentration and capillary electrophoresis (CE) for the subsequent analysis are hyphenated for the analysis of peptides and proteins. The reproducibility of such a column has been proved good with relative standard deviations (RSDs) of dead time of less than 5% for injection-to-injection and 12% for column-to-column (n = 3). Through application on the analysis of standard peptides and real protein samples, such a technique has shown promising in proteome study.