129 resultados para Antimicrobial Cationic Peptides


Relevância:

20.00% 20.00%

Publicador:

Resumo:

研究背景与目的:近二十年来,抗生素的广泛使用以及一些不当应用导致临床上出现大量的耐药性病原菌,所以不易产生耐药性的抗菌肽就成为目前研究的热点。本课题组此前的研究表明无指盘臭蛙(Odorrana grahami)皮肤抗菌肽具有广谱抗菌活性,但对真核细胞没有毒性,因此有成为新型药物的潜力。本研究采用毕赤酵母真核表达系统来生物合成抗菌肽Odorgrin A和Odorgrin C,为大量获取抗菌肽资源提供技术支撑。 方法:依照Odorgrin A和C的氨基酸序列、采用酵母偏爱密码子分别设计并化学合成了相应的目的基因序列。目的片段从合成质粒上用Xho Ι和EcoR Ι双酶切下后,与经同样限制酶完全酶切pPIC9K载体所获得的两个大片段直接连接,并转化至大肠杆菌DH5α。用PCR扩增、酶切及测序检测,鉴定正确的重组质粒。提取大量表达载体pPIC9K - Odo A和C并使之线性化后经电击法分别转化毕赤酵母(Pichia pastoris)GS115宿主菌,用营养缺陷型筛选、遗传霉素抗性筛选、PCR扩增和测序检测,鉴定并筛选出对G418具高抗性的Odorgrin A和C重组酵母菌。用甲醇对之进行诱导表达,SDS - PAGE电泳及反相层析检测表达产物,并做抑菌活性检测。 成果:PCR扩增、酶切及测序等结果表明表达载体pPIC9K - Odo A和C构建成功。营养缺陷型筛选、遗传霉素抗性筛选、PCR扩增和测序等证实pPIC9K - Odo A和C已整合入酵母基因组中。SDS - PAGE电泳及反相层析结果表明抗菌肽Odorgrin A和C成功地获得了分泌表达。而抑菌活性实验则检测到部分阳性克隆菌诱导分泌表达的抗菌肽Odorgrin A和C都对测试菌的生长具有较高(>94%)的抑制率。 结论:无指盘臭蛙皮肤抗菌肽Odorgrin A和Odorgrin C基因的表达载体都构建成功,并且都在毕赤酵母系统中获得了成功表达。 Background & Objective: In the recent twenty years, a lot of pathogenic bacteria have come forth in clinic with durable trait derived from making use of and abusing the traditional antibiotics. Therefore, studying antimicrobial peptides, not be easy to be invalidated by durable bacteria, are becomimg popular and important. The skin antimicrobial peptides of Odorrana grahami with broad spectrum antibacterial activity and no toxicity to eukaryotic cell, discovered by previous research work of our workgroup, are looked forward to being potential medication. Pichia pastoris expressional system was used for biosynthesis antimicrobial peptides Odorgrin A and Odorgrin C in this study, for producing abundant antimicrobial peptides. Methods: The foreign fragments which included Odorgrin A or Odorgrin C gene according to their amino acid sequence respectively were synthesized based on the biased codon usage of yeast. The DNA fragments, obtained from the plasmids containing them by digested with Xho Ι and EcoR Ι, were directly ligated with the two bigger fragments obtained from the vector pPIC9K by digested with the same restriction enzymes. And then they were transformed into Escherichia coli DH5α to be selected and amplified positive colonies. The recombinants were testified by using PCR amplification, enzymes digestion and sequencing of the foreign fragment. After the expressional vector pPIC9K - Odo A and pPIC9K - Odo C were linearized, they were transformed into Pichia pastoris GS115 strain by the electroporation. Then the positive colonies which were of the highest geneticin resistant were selected through auxotrophic screening, genetic resistant screening, PCR amplification and sequencing of the inserted fragment. Methanol was used to induce the recombinant yeasts to express the foreign gene. SDS-PAGE electrophoresis, reversed phase chromatography and antibacterial activity experiment were used to testify the expressional products. Results: The evidences of PCR, enzymes digestion and sequence analysis confirmed that the expressional vector pPIC9K - Odo A and pPIC9K - Odo C have been constructed correctly. The results of auxotrophic screening, of genetic resistant screening, of PCR and sequencing of the foreign fragment showed that Odorgrin A and Odorgrin C gene have been homologous integrated with the Pichia pastoris genome. And it was also testified that antimicrobial peptides Odorgrin A and Odorgrin C have been expressed successfully by using SDS - PAGE electrophoresis, reversed phase chromatography and antibacterial activity experiment. Conclusion: The expressional vector of the skin antimicrobial peptides Odorgrin A and Odorgrin C gene of Odorrana grahami have been constructed correctly and both of the genes have been expressed successfully in Pichia pastoris system in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressurized capillary electrochromatography (pCEC) was coupled with electrospray ionization mass spectrometry (ESI-MS) using a coaxial sheath liquid interface. It was used for separation and analysis of peptides and proteins. The effects of organic modifier and applied voltage on separation were investigated, and the effects of pH value of the mobile phase and the concentration of the electrolyte on ESI-MS signal were investigated. The resolution and detection sensitivity with different separation methods (pCEC, capillary high-performance liquid chromatography) coupled on-line with mass spectrometry were compared for the separation of a peptide mixture. To evaluate the feasibility and reliability of the experimental setup of the system, tryptic digests of cytochrome c and modified protein as real samples were analyzed by using pCEC-ESI-MS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we used a rheological method to study the shape of DNA-cationic lipid complexes and model polyelectrolyte-lipid complexes. We introduced two kinds of anionic polyelectrolytes, sodium polygalacturonate (PGU) and sodium dextran sulfate (DSS), of varying size, as models for DNA. The prepared complexes were incubated under laminar flow conditions. The results show the same quantitative relation between the shape parameter of lipoplexes and the length of anionic polyelectrolytes, including DNA. The rheological behavior of PGU and DSS were similar to that of DNA. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A polymer-based monolithic capillary column imprinted with 4-aminopyridine (4-AP) was prepared by a thermally-initiated polymerization process; and its performance as a capillary electrochromatographic medium was evaluated in separating 4-AP and 2-AP isomers. The effects of experimental parameters, such as pH value and ionic strength of the buffer, the acetonitrile content in the mobile phase, and the applied voltage, on the resolution of these isomers had been carefully investigated. It was found that in the retention process there were interplays of multiple mechanisms of ion-exchange, molecular imprinting, and electrophoresis. These mechanisms allowed more sophisticated control of experimental parameters in the separation of ionizable compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mixed mode of reversed phase (RP) and strong canon-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for to and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the sensitive determination of amino acids and peptides using the tagging reagent 2-(9-carbazole)-ethyl chloroformate (CEOC) with fluorescence (FL) detection has been developed. Identification of derivatives was carried out by liquid chromotography mass spectrometry. The chromophore in the 2-(9-fluorenyl)-ethyl chloroformate (FMOC) reagent was replaced by carbazole, which resulted in a sensitive fluorescence lerivatizing agent CEOC. CEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. Studies on derivatization demonstrate excellent derivative yields over the pH range 8.8-10.0. Maximal yields close to 100% are observed with three- to fourfold molar reagent excess. Derivatives exhibit strong fluorescence and allow direct injection of the reaction mixture with no significant disturbance from the major fluorescent reagent degradation by-products, such as 2(9-carbazole)-ethanol and bis-(2-(9-carbazole)-ethyl) carbonate. In addition, the detection responses for CEOC derivatives are compared to those obtained with FMOC. The ratios AC(CEOC)/AC(FMOC) = 1.00-1.82 for fluorescence (FL) response and AC'(CEOC)/AC'(FMOC) = 1.00-1.21 for ultraviolet (UV) response are observed (here, AC and AC' are, respectively, FL and UV F response). Separation of the derivatized peptides and amino acids has been optimized on a Hypersil BDS C18 column. Excellent linear responses are observed. This method was used successfully to analyze protein hydrolysates from wool and from direct-derivatized beer. (C) 2003 Elsevier Science (USA). All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pressurized electrochromatography (pCEC) instrument with gradient capability was used in this work for separation of peptides. Three separation modes, namely, pCEC, high-performance liquid chromatography and capillary electrophoresis can be carried out with the instrument. In pCEC mode, the mobile phase is driven by both electroosmotic flow and pressurized flow, facilitating fine-tuning in selectivity of neutral and charged species. A continuous gradient elution can be carried out conveniently on this instrument, which demonstrates that it is more powerful than isocratic pCEC for separation of complicated samples. The effects of applied voltage, supplementary pressure and ion-pairing agents on separation of peptides in gradient pCEC were investigated. The effects of flow-rate of the pump and the volume of the mixer on resolution were also evaluated. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pressurized capillary electrochromatography (pCEC) instrument with solvent gradient capability has been used for the separation of a peptide mixture. Retention mechanism and selectivity of the peptides were studied by pCEC using a strong cation exchange (SCX) column. The effects of applied voltage, supplementary pressure, organic modifier concentration, ionic strength,, and pH value on pCEC separation were investigated. It was found that the retention mechanism of the peptides in this system is based on a mixed mode of hydrophilic interaction, strong cation exchange, and electrophoresis. Compared with the separation results obtained by reverse phase pCEC and capillary electrophoresis (CE), this mixed-mode pCEC is more powerful for the separation of hydrophilic peptides with similar charge-to-mass ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mode of capillary electrochromatography for separation of ionic compounds driven by electrophoretic mobility on a neutrally hydrophobic monolithic column was developed. The monolithic column was prepared from the in situ copolymerization of lauryl methacrylate and ethylene dimethacrylate to form a C-12 hydrophobic stationary phase. It was found that EOF in this hydrophobic monolithic column was very poor, even the pH value of mobile phase at 8.0. The peptides at acidic buffer were separated on the basis of their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase; therefore, different separation selectivity can be obtained in CEC from that in capillary zone electrophoresis (CZE). Separation of peptides has been realized with high column efficiency (up to 150 000 plates/meter) and good reproducibility (migration time with RSD < 0.5%), and all of the peptides, including some basic peptides, showed good peak symmetry. Effects of the mobile phase compositions on the retention of peptides at low pH have been investigated in a hydrophobic capillary monolithic column. The significant difference in selectivity of peptides in CZE and CEC has been observed. Some peptide isomers that cannot be separated by CZE have been successfully separated on the capillary monolithic column in this mode with the same buffer used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schiff base compounds refer to the branch of supra-molecules and can be used as sensing material in the construction of potentiometric ion selective electrodes (ISEs). This relatively modern field has been subject to extensive research in the period of 1999-2007 when more than 100 ISEs employing Schiff bases were constructed. The quantitative high-throughput detection of 29 cations and 7 anions has been demonstrated in various scientific branches, such as biomedicine, pharmacy, biochemistry, pharmacology, environmental chemistry, food technology, and agriculture. This review discusses Schiff base compounds and their applications in the design and development of ion selective sensors and microsensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel ampholytic terpolymer of N-vinylformamide (NVF), vinylamine (VAm) and sodium acrylate (NA) with low cationic proportion was obtained by hydrolyzing copolymer of NVF and NA (PNVFNA). Solution properties of the polymer were investigated by methods of turbidity and viscosity experiment. The effect of sodium dodecyl sulfate (SDS) on solution viscosity was also investigated. The results showed that the turbidity curves were bimodal, and pH 3.0 was determined as the isoelectric point (IEP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we demonstrated dimethyldioctadecylammonium bromide (DODAB), a cationic lipid, bilayer coated Au nanoparticles (AuNPs) could efficiently deliver two types of plasmid DNA into human embryonic kidney cells (HEK 293) in the presence of serum. The transfection efficiency of AuNPs was about five times higher than that of DODAB. The interaction of AuNPs with DNA was characterized with dye intercalation assay and agarose gel electrophoresis. The morphology of the complex of AuNPs with DNA was observed with scanning electron microscope (SEM). The intracellular trafficking of the complex was monitored with transmission electron microscope (TEM).