119 resultados para compression parallel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of signed-digit negabinary representation, parallel two-step addition and one-step subtraction can be performed for arbitrary-length negabinary operands.; The arithmetic is realized by signed logic operations and optically implemented by spatial encoding and decoding techniques. The proposed algorithm and optical system are simple, reliable, and practicable, and they have the property of parallel processing of two-dimensional data. This leads to an efficient design for the optical arithmetic and logic unit. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact two-step modified-signed-digit arithmetic-logic array processor is proposed. When the reference digits are programmed, both addition and subtraction can be performed by the same binary logic operations regardless of the sign of the input digits. The optical implementation and experimental demonstration with an electron-trapping device are shown. Each digit is encoded by a single pixel, and no polarization is included. Any combinational logic can be easily performed without optoelectronic and electro-optic conversions of the intermediate results. The system is compact, general purpose, simple to align, and has a high signal-to-noise ratio. (C) 1999 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on birefringence, a building-block stacking technique is suggested in this paper. A solid-state optical morphological processor module is thus developed, which is an integration of a beam array generator submodule, an optical connector submodule, and a Pockels readout optical modulator. It is shown that the technique is compact in construction, simple for fabrication, and insensitive to the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negabinary is a component of the positional number system. A complete set of negabinary arithmetic operations are presented, including the basic addition/subtraction logic, the two-step carry-free addition/subtraction algorithm based on negabinary signed-digit (NSD) representation, parallel multiplication, and the fast conversion from NSD to the normal negabinary in the carry-look-ahead mode. All the arithmetic operations can be performed with binary logic. By programming the binary reference bits, addition and subtraction can be realized in parallel with the same binary logic functions. This offers a technique to perform space-variant arithmetic-logic functions with space-invariant instructions. Multiplication can be performed in the tree structure and it is simpler than the modified signed-digit (MSD) counterpart. The parallelism of the algorithms is very suitable for optical implementation. Correspondingly, a general-purpose optical logic system using an electron trapping device is suggested. Various complex logic functions can be performed by programming the illumination of the data arrays without additional temporal latency of the intermediate results. The system can be compact. These properties make the proposed negabinary arithmetic-logic system a strong candidate for future applications in digital optical computing with the development of smart pixel arrays. (C) 1999 Society of Photo-Optical Instrumentation Engineers. [S0091-3286(99)00803-X].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulse compression induced by cross-phase modulation in birefringent dispersion decreasing fiber is discussed theoretically by solving the coupled Schrodinger equations which include the contribution of the high-order non-linear effects, and third-order dispersion. In particular, it is found that a high quality compressed signal pulse can be obtained by a pump pulse of low intense through the technique. The dependence of optimum compression on the non-linear factor N, time delay tau(d) and the dispersive ratio f is also discussed in detail. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a full-range parallel Fourier-domain optical coherence tomography (FD-OCT) in which a tomogram free of mirror images as well as DC and autocorrelation terms is obtained in parallel. The phase and amplitude of two-dimensional spectral interferograms are accurately detected by using sinusoidal phase-modulating interferometry and a two-dimensional CCD camera, which allows for the reconstruction of two-dimensional complex spectral interferograms. By line-by-line inverse Fourier transformation of the two-dimensional complex spectral interferogram, a full-range parallel FD-OCT is realized. Tomographic images of two separated glass coverslips obtained with our method are presented as a proof-of-principle experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grating pairs are widely used for pulse compression and stretching. Normally, the two gratings are identical. We propose a very simple structure with double-line-density reflective gratings for pulse compression and generation of double pulses, which has the advantages of no material dispersion, compact in volume, simple in structure, etc. The use of reflective Dammann gratings fully demonstrated the principle of this structure. The output pulses are well verified by a standard frequency-resolved optical gating apparatus. This structure will be highly interesting in ultrashort pulse compression and other more practical applications of femtosecond laser pulses. (c) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When noises considerations are made, nonredundant arrays (NRAs) are endowed with many advantages which other arrays e.g., uniformly redundant arrays (URAs) do not possess in applications of coded aperture imaging. However, lower aperture opening ratio limits the applications of NRA in practice. In this paper, we present a computer searching method based on a global optimization algorithm named DIRECT to design NRAs. Compared with the existing NRAs e.g., Golay's NRAs, which are well known and widely used in various applications, NRAs found by our method have higher aperture opening ratio and auto correlation compression ratio. These advantages make our aperture arrays be very useful for practical applications especially for which of aperture size are limited. Here, we also present some aperture arrays we found. These aperture arrays have an interesting property that they belong to both NRA and URA. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Far-field spot compression without energy loss in main lob is of great significance to wireless laser communication. In this letter, we propose two schemes to obtain far-field spot compression without energy loss in main lob. One scheme is based on the simulated annealing (SA) algorithm. Using SA algorithm, we design the phase profile of the diffractive phase element (DPE). Using the designed DPE, far-field spot compression without energy loss in main lob is achieved. The other scheme is based on YG algorithm. By means of YG algorithm, we appropriately designed the DPE in the emitting plane. Using the DPE, far-field spot compression without energy loss in main lob is obtained. (c) 2007 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement accuracy of a parallel-plate interferometer for angular displacement measurement is analyzed. The measurement accuracy of angular displacement is not only related to the accuracy of phase extraction, but also related to initial incident angle, refraction index and thickness of plane-parallel plate as well as wavelength's stability of laser diode, etc. Theoretical analysis and computer simulation show that the measurement error of the angular displacement bears a minimum value when choosing an optimal initial incident angle in a large range. These analytical results serve as a guide in practical measurement. In this interferometer, reducing the refraction index or increasing the thickness of the parallel plate can improve the measurement accuracy; and the relative error of the phase measurement is 3.0 x 10(-4) corresponding to 1 degrees C temperature variation. Based on these theoretical and experimental results, the measurement accuracy of the parallel-plate interferometer is up to an order of 10(-8) rad. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel method of one-shot parallel complex Fourier-domain optical coherence tomography using a spatial carrier frequency for full range imaging. The spatial carrier frequency is introduced into the 2-D spectral interferogram in the lateral direction by using a tilted reference wavefront. This spatial-carrier- contained 2-D spectral interferogram is recorded with one shot of a 2-D CCD camera, and is Fourier-transformed in the lateral direction to obtain a 2-D complex spectral interferogram by a spatial-carrier technique. A full-range tomogram is reconstructed from the 2-D complex spectral interferogram. The principle of this method is confirmed by cross-sectional imaging of a glass slip object. (c) 2008 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key issues of engineering application of the dual gratings parallel matched interrogation method are expanding the measurable range, improving the usability, and lowering the cost by adopting a compact and simple setup based on existing conditions and improving the precision of the data-processing scheme. A credible and effective data-processing scheme based on a novel divisional look-up table is proposed based on the advantages of other schemes. Any undetermined data is belonged to a certain section, which can be confirmed at first, then it can be looked up in the table to correspond to microstrain by the scheme. It not only solves inherent problems of the traditional one (double value and small measurable range) but also enhances the precision, which improves the performance of the system. From the experimental results, the measurable range of the system is 525 mu epsilon, and the precision is +/- 1 mu epsilon based on normal matched gratings. The system works in real time, which is competent for most engineering measurement requirements. (C) 2007 Elsevier GmbH. All rights reserved.